Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Electrolux, модель 584143

Производитель: Electrolux
Размер: 1.01 mb
Название файла: ca0e9bc7-3cbd-4331-9ac9-1f457451f29d.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


The larger gap (b / Fig.3) on the fastener must be at the bottom. O Affix the fasteners (3 / Fig.3) to the plinth (2 / Fig.3). O The larger gap (b / Fig.3) on the fastener must be at the bottom. O Attach the plinth with the fasteners (3 / Fig.3) onto the feet. Fig.4 Assemblage on castors The assembly kit for mounting on castors contains two cross bars (2/Fig.4a) each with a fixed rear wheel (1/Fig.4a) and a turnable front wheel (3/Fig.4a). Mounting the castors: O Put the appliance on supports. O Remove the feet; each is tightened with four screws (Fig.4b). O Bring the two cross bars into the correct position below the appliance and fasten it with 8 screws arrows (Fig.4a). O Remove the supports. O Fasten the appliance to the building. Use the hole to attach a chain descending from the wall (arrow/Fig.4c). Making sure the chain is shorter than the gas and electric connections. Note: Appliances on wheels must be secured by fasten it to the building. 2. Note: ACCESS TO INTERIOR Only authorized technicians may access the interior. B D Fig. 5 General view 62.95В2.01 UL Page 5 (3) b (1) a E b 0] Electrolux INSTALLATION INSTRUCTIONS 2.1 FRONT PANELS (A) and (B) 3. DOWNPIPE Fig.6 Front panel O Unscrew screws (1 or 3). Also, in the case of a built-in oven, unscrew screws (2 and/or 4) on the inside of the oven. O Pull the panel away forwards and downwards. 2.2 CONTROL PANEL (C) Fig. 7 Control panel Fig. 8 Downpipe Work surfaces with a downpipe (Fig.8a) have the downpipe opening on the right-hand side of the appliance. A flexible silicon hose when installed in the standard manner ends underneath and to the right, 20 mm behind the front of the appliance (Fig.8b). O Alternatively, the hose can be relocated to the rear and be routed through other pre-cut openings (Fig.8c). a b c O Remove the knob. O Loosen the screws underneath (1 / Fig.7a) and remove the base plate. O Loosen the screws (2 / Fig.7b) and 3 / Fig.7c) O Remove the panel. 2.3 OVEN, STORAGE SPACE, HOT CABINET O Remove panels A, B and C. O Undo screws (5). O Pull out element. Page 6 62.9582.01 UL INSTALLATION INSTRUCTIONS H Electrolux 4. ELECTRICAL CONNECTION Each appliance is accompanied by a complete connection and wiring diagram enclosed. This contains full details of the technical specifications (electrical rating, voltage, amperage etc.) Check and ensure that the mains voltage agrees with the voltage given on the specification plate. N.B.: • The corresponding arrangements must be made on-site for the earthing connection and fuse protection for the appliances. • The appliance must be connected to a potential equalization system ^ with a minimum conductor crosssection of 1o mm2. The correspondingly marked connection terminal must be used for this purpose. When set up in block configuration, all appliances must be interconnected as potential equalization. • The appliance is designed for connection to fixed lines. If the appliance is fitted directly to a masonry plinth without an appliance plinth, the supply must be located at the prescribed place. In this case, the protecting tube may not protrude from the plinth. If a CNS base is used, the protecting tube may not protrude more than 10 cm from the floor. • After installation, the shock-hazard protection for live and functionally insulated parts must be secured. • An isolating device working on all poles and with a minimum contact opening of 3 mm must be provided on site. • When faulty-current circuit breakers are used, ones for a rated tripping current of 30 mA should be used. • When using a faulty current-operated circuit-breaker (in the case of an existing circuit-breaker and for new installations) only a one pulse-current sensitive faulty current-operated circuit-breaker may be connected in series in conjunction with these appliances. 4.1 CONNECTION TERMINALS 4.2 CONNECTION TO THE POTENTIAL EQUALIZATION SYSTEM The appliance is to be connected to a potential equalization system with a minimum conductor cross-section of 10 mirP. Use the appropriately marked terminal studs for this purpose (EN 60 335). The connection consists of an M6 threaded bolt and is located on the frame of the appliance. Connection as per sketch. 1 Cable shoe * 6 mm 2 Nut M 6 3 Spring washer M 6 4 Washer M 6 Fig.10 Connection to the potential equalization system Fig.9 Connection terminals Power is taken from a ready-installed electric cable which protrudes 1.5 m from the floor or the wall. The connection terminals for the appliance are located behind the front right-hand cover (B). In order to connect the appliance, the front panel must be removed (see Chapter 2.1 on page 6). Power cable connection as per the electrical diagram. The terminal screws on the range frame are marked as follows: Earth wire (J) Potential equalization ^ Additional terminals for power optimizing systems (EO/SI) or potential-free contacts (PK) for the external monitoring of the appli...

Эта инструкция также подходит к моделям:
Варочные панели - 584142 (1.01 mb)
Варочные панели - 584144 (1.01 mb)
Варочные панели - 584145 (1.01 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории