This running time is preset by the installer based on the humidifier model and water characteristics. Refer to the Annual Maintenance section for instructions on changing the Water Panel or call your heating and air conditioning dealer for service. After the Water Panel is replaced, turn the Control knob to the “Test/Reset” position until the green “Humidifier ON” light flashes, to reset the Water Panel change timer. TEST/RESET The Test/Reset feature allows the humidifier operation to be checked even if there is no call for humidity. See “Check the Humidifier Operation” on page 9. ADDITIONAL INFORMATION Your humidifier is a precision system that will accurately maintain the RH in your home. For every 2°F change in outdoor temperature, the Automatic Digital Humidifier Control will automatically adjust the indoor RH by 1%. The Automatic Digital Humidifier Control will accurately control the humidity in your home to a maximum of 45% RH and a minimum of 10% RH. The RH Values in Table 2 are targets based on outdoor temperature and the ADHC control setting. The actual RH may vary due to conditions in the home (cooking, showering, etc.). TABLE1OutdoorTemperature/IndoorRelativeHumidity Outside Temperature Recommended RH +40°F 45% +30°F 40% +20°F 35% +10°F 30% 0°F 25% –10°F 20% –20°F 15% TABLE 2 % Relative Humidity Guide Outdoor Temperature (°F) -10°F 0°F 10°F 20°F 30°F 40°F Dial Setting1 10% 10% 10% 15% 20% 25% Relative Humidity (% ) 2 10% 10% 15% 20% 25% 30% 3 10% 15% 20% 25% 30% 35% 4 15% 20% 25% 30% 35% 40% 5 20% 25% 30% 35% 40% 45% 6 25% 30% 35% 40% 45% 45% 7 30% 35% 40% 45% 45% 45% -6--7- OPERATINGINSTRUCTIONS– MODELS350,360,400M,500M,600M&700MOPERATINGINSTRUCTIONS– MODELS350,360,400M,500M,600M&700M TABLE 3 Operation Guide Condition Solution Condensation on windows. Reduce the setting on the control dial by 1 increment. Lack of humidity. Increase the setting on the control dial by 1 increment. Humidifier does not operate. (Solenoid does not “click” when control is moved to “Test/Reset” position.) Turn dial to “Test/Reset”. Make certain HVAC blower is operating and HVAC is calling for heat. If unit still does not operate, consult a heating contractor. Humidifier won’t shut off. Turn dial to “Off”. If unit continues to operate, consult a heating contractor. Test mode. System operation is checked by setting the knob to “Test/Reset”. Make certain HVAC blower is operating and HVAC is calling for heat. Humidifier will operate for one minute. NOTE: Placing the knob in “Test/Reset” resets the Water Panel change timer. Red “Call Dealer for Service” light flashes (Figure A). Note the error code on the display (E1, E2, E3 or E4) and call your heating and air conditioning dealer. Yellow “Change Water Panel” light flashes (Figure A). Refer to the Annual Maintenance section (page 11) for instructions on changing the Water Panel or call your heating and air conditioning dealer for service. After the Water Panel is replaced, turn the Control knob to the “Test/Reset” position until the green “Humidifier On” light flashes, to reset the Water Panel change timer. FIGUREC–ManualHumidifierControl90-1237 Your Aprilaire humidifier is controlled by a Manual Humidifier Control (see Figure C). The Manual Humidifier Control is installed either in the cold air return duct or on an interior wall of the home. With the Manual Humidifier Control, it is important to anticipate a drop in outdoor temperature and reduce the setting accordingly to avoid excessive condensation, just as with the Automatic Digital Humidifier Control installed in Manual Mode (see page 6). To determine the indoor RH, slowly turn the knob clockwise and counterclockwise and listen for 2 clicks....
Эта инструкция также подходит к моделям:Увлажнители воздуха - 500M (817.44 kb)
Увлажнители воздуха - 350 (817.44 kb)
Увлажнители воздуха - 360 (817.44 kb)
Увлажнители воздуха - 400M (817.44 kb)