|
Фрагмент инструкции
DO NOT IMMERSE WATER BASIN IN WATER. 3. Wipe all exteriors surfaces of the base with a soft, dry cloth. Do not immerse the base in water or use water to clean the base. An electric shock may result or the humidifier may be damaged. NOTE: It is recommended to clean humidifier with water and bleach solution as stated above after using the humidifier the fourth time. GENERAL MAINTENANCE AND CLEANING Before any cleaning operation, switch the humidifier off and unplug it. 1. Always unplug the unit before cleaning. 2. The humidifier must be drained and cleaned before storing. 3. Once unplugged the exterior of the unit may be cleaned by wiping with a soft dry cloth. Caution: The ON/OFF switch must be thoroughly dry before unit is again plugged into power source. 4. There may be some lime deposits in the nebulizer, particular in areas with hard water. Overcome this drawback by cleaning the nebulizer with water and vinegar on a soft cloth regularly, as follows: A. Dampen a cloth with vinegar and wipe the nebulizer gently, until the lime deposits disappear completely. B. Rub down gently with a dry cloth and remove remains of humidity. C. Do not rub the nebulizer with solid objects. D. Do not clean with chemical products 5. When cleaning the water basin do not place the nebulizer directly under the water tap. 6. Never immerse the unit in water or let water enter the fan vent (see figure 3) or any other openings. 7. It is normal for water to be in the water basin. However water must not get inside the central body. If this should happen, take the humidifier to an authorized service center before using it again. 8. Clean the inside of the water tank at least once a week, as follows: A. Fill the tank with clean water adding a few drops of bleach. Close the tank completely with its cap and shake by holding the tank with both hands. Do not hold by handle while shaking the tank. B. Rinse thoroughly. Water Level Sensor- The water level sensor is made of three key parts. When cleaning DO NOT MISPLACE these parts and MAKE SURE that you assemble these three parts correctly after cleaning and before operating humidifier. They are as follows: Plastic Cap – this part has 4 flat tabs coming out from the bottom and is placed on top of a plastic pin. Water Float - a small round part resembling a “life saver” candy located underneath the plastic cap. Pin – plastic pin that secures water float and plastic cap. To clean the water float unscrew the plastic cap from the pin. Remove the water float and clean by wiping the parts with a soft damp cloth. Replace the parts by first putting the water float onto the pin and re-screwing the plastic cap onto pin. STORING YOUR HUMIDIFIER Allow the appliance to dry completely before storing. Store the appliance in a dry location. Do not place any heavy items on top of appliance during storage as this may result in possible damage of the appliance. Store the cord in a clean, dry location away from metal objects. Always check the plug before use to assure metal items have not become attached. .. Save the box for off-season storage. .. Make sure the tank, water basin and water tank cap are thoroughly dry before storing. .. If water is left in the unit during storage, it may evaporate completely and leave deposits that can prevent the unit from operating properly. Leave the water tank refill cap loose to prevent the water cap (see figure 4) and gasket from sticking together. This will prolong the life of the gasket. TROUBLE SHOOTING CAUTION: DO NOT attempt to repair the motor or nebulizer yourself. If the humidifier continues to not operate please call our service center (see toll free number). Problem Solution Humidifier power light is staying red and not turning green Humidifier is working than stops: .. Ensure that water level sensor is assembled properly. .. Clean water float .. Call service center and request replacement water float .. If humidifier does not work at all: .. Ensure it is properly plugged into a power outlet. .. Check that the switch is in the ON position. .. If Power On indicator light does not come on, bring to authorized service station. If there is a strange odor: .. Clean the tank with water and vinegar or bleach and rinse with clean water. .. Leave the tank open for some time without the cap, in a cool place. The power light is green but there is no mist being emitted: .. Check that there is water in the tank. .. Check for possible lime deposits on the water level sensor or the nebulizer (see page 8 and 9). .. Make sure that nothing blocks the vapor output slots. .. Check that the fan vent on bottom of humidifier is not blocked. .. Empty the humidifier and rinse the water basin with cool tap water and allow to dry for 15 to 30 min. White dust appears and settles outside the humidifier: .. Area tap water may have too many minerals, change to filtered or distilled water. SERVICE CENTER If you have any question in regards to the operation of this appliance or are in need of a spar...
Эта инструкция также подходит к моделям:Увлажнители воздуха - EE-865 (793.17 kb)