Войти:
Оценок - 5, средний балл: 3.6 ( )

Инструкция по эксплуатации Bard, модель WUVCLP-A

Производитель: Bard
Размер: 1.43 mb
Название файла: 46441700.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. • Never operate the UV Air Purifying System out of the plenum. WARNING: UV light will break down plastic materials not rated for UV exposure: (Examples: wire insulation, flex duct, drain pans and humidifiers) • The unit must be mounted at least 30” from the above stated type of materials. • If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded with aluminum foil, aluminum foil tape, or sheet metal. The WUVCLP light package should only be installed by a trained heating and air conditioning technician. These instructions are not intended to be a stepby- step procedure that the mechanically inclined owner can use to install the WUVCLP light package. Rather these instructions serve as a guide to the technician installing the WUVCLP light package Bard Manufacturing Company Manual No.: 2100-432 Bryan, Ohio 43516 Supercedes: File: Vol III Tab 19 Since 1914…Moving ahead, just as planned. Date: 2/14/03 Table of Contents Table of Contents Page No. General Unpacking ...................................................................................................Page 1 Description ..................................................................................................Page 1 Installation Basic Installation .........................................................................................Page 3 Wiring 230 Volt Single Phase and Three Phase Units Only ..........................Page 7 460 Volt Three Phase Units Only .......................................................Page 8 Checkout ...................................................................................................Page 10 Parts List ............................................................................................................Page 10 Figures Figure 1 Bracket Adjustment .........................................................Page 5 Figure 2 Removal of Exterior Panels ............................................Page 6 Figure 3 Mounting Hole Locations ................................................Page 6 Figure 4 Right Side Bracket Installation ........................................Page 6 Figure 5 Left Side Bracket Location ..............................................Page 7 Figure 6A&B 240 V Conduit Routing ....................................................Page 7 Figure 7A&B Harness Wiring ...............................................................Page 8 Figure 8 460 V Transformer Location ...........................................Page 8 Figure 9 460 V Conduit Routing ....................................................Page 9 Figure 10 Wiring Diagram .............................................................Page 11 Tables Table 1 Compatibility Charts ........................................................Page 4 Table 2 Wall Mount Unit Widths ..................................................Page 5 Page 2 I. GENERAL This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition. UNPACKING The WUVCLP light package is shipped in one carton, which contains the electrical wires, UV light assembly, UV light bulb, 4 mounting screws, alcohol wipe, transformer for the 460 volt models, and installation instructions. Upon receipt of the carton be sure to compare the model number found on the shipping label with the accessory identification information on the ordering and shipping document to verify that the correct accessory has been shipped. Before signing the freight bill, inspect the carton of each ultraviolet light assembly as it is received to verify that all the ordered items have been received and that no damage has occurred to any of the items during shipping. Note any shortages or damage on all copies of the freight bill. The receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent. Concealed damage of equipment not discovered until after unloading must be reported to the carrier within 15 days of its receipt. DESCRIPTION The WUVCLP-A (208/230 volt) and WUVCLP-C (460 volt) ultraviolet Light air purifiers are designed to be installed in all 1-1/2 through 6 ton Bard wall mounted products. They are electrical ultraviolet lights designed to reduce indoor air contamination and prevent growth of new microorganisms (mold and bacteria). Specifications: Electrical: 60 watts Bulb Size: 28” length Application: WA18 through WA72 WH18 through WH61 WH261 through WH611 SH261 through SH611 Models: The WUVCLP-A is compatible with all 230/208 volt single and three phase, Bard 1-1/2 through 6 ton wall mount units. The WUVCLP-C is compatible with all 460 volt three phase, Bard 1-1/2 through 6 ton wall mount uni...

Эта инструкция также подходит к моделям:
Прочие персональные приборы - WUVCLP-C (1.43 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории