Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Toshiba, модель FS-2600-1

Производитель: Toshiba
Размер: 897.17 kb
Название файла: ca7f7d5a-5caf-4832-9e81-efc156ddc6bb.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Mode Lock: SET * SET * 02-06-1999 12:34 PROGRAMMING PLU KEY 01 02 03 04 05 S1 Please input item No. 0.00 27 [X] |Keyboard No.| [ST] |PLU Code or Display Menu Table No.| [KEY] 1: ECR Keyboard 1 Max. 6 digits for PLU Code Depress 2: ECR Keyboard 2 1 to 99 for Display Menu Table No. the 3: ECR Keyboard 3 (Enter 0 to close a key) required 4: ECR Keyboard 4 key on 5: ECR Keyboard 5 the ECR Keyboard. [AT/TL] Repeat for other Keys. ex.) To assign the PLU code 9 to the required key on the ECR Keyboard 2 and the display menu table No. 2 to the required key on the ECR Keyboard 5. Mode Lock: SET Enter 27, depress [X]. 2 [ST] 9 [required key of SFKC 96] 5 [ST] 2 [required key of SFKC 210] [AT/TL] Journal Print P27 PLU KEY Keyboard Phase No. 2 PLU Location Code (left); refer to REMARK on the next page. #103 000009 PLU Code assigned to a key (right) 5 DISPLAY #075 02 0046 16:21TM NOTES: 1. When an entry of PLU code or display menu table No. is skipped and a [KEY]is simply depressed in the above key operation, the preprogrammed PLU code or display menu table No. of the KEY will be displayed. 2. If “0” is entered as PLU Code or display menu table No. in the above sequence, the KEY will be closed. Pressing the closed KEY in sale entry will be ignored. 3. The five phases of the keyboard can be shifted by the[MENU]keys in actual sales transaction. 5-36 5. PROGRAMMING OPERATIONS EO1-11138 5.4 How to Access a Program Item REMARK: When a PLU code (display menu No.) is assigned to a PLU Preset-code Key (Display Key) on the ECR Keyboard in the operation on the preceding page, the Hardware Key Code which indicates the absolute location of the key will be printed to the left of the assigned PLU Code (display menu No.). The Hardware Key Codes of the ECR keyboard are shown below. ECR Keyboard 1 16 31 46 61 76 91 106 2 17 32 47 62 77 92 107 3 18 33 48 63 78 93 108 4 19 34 49 64 79 94 109 5 20 35 50 65 80 95 110 6 21 36 51 66 81 96 111 7 22 37 52 67 82 97 112 8 23 38 53 68 83 98 113 9 24 39 54 69 84 99 114 10 25 40 55 70 85 100 115 11 26 41 56 71 86 101 116 12 27 42 57 72 87 102 117 13 28 43 58 73 88 103 118 14 29 44 59 74 89 104 119 15 30 45 60 75 90 105 120 121 136 151 166 122 137 152 167 123 138 153 168 124 139 154 169 125 140 155 170 126 141 156 171 127 142 157 172 128 143 158 173 129 144 159 174 130 145 160 175 131 146 161 176 132 147 162 177 133 148 163 178 134 149 164 179 135 150 165 180 Navigation Key 181 182 183 184 185 Navigation Key 1 Navigation Key 2 Navigation Key 3 Navigation Key 4 Navigation Key 5 5-37 5. PROGRAMMING OPERATIONS EO1-11138 5.4 How to Access a Program Item n PLU Group Name Programming (Submode 29) This programming is used to set each PLU group name. Grouping of each PLU should be set in the PLU Table Programming (Submode 4). CONDITION OPERATION Any time outside a sale When you enter 29 and depress the [X] key, the screen shown below will appear. Mode Lock: SET * SET * 02-06-1999 12:34 PROGRAMMING PLU GROUP 01 PLU GP01 02 PLU GP02 03 PLU GP03 04 PLU GP04 05 PLU GP05 06 PLU GP06 07 PLU GP07 . 08 PLU GP08 Please input item No. 0.00 Pg up Pg dw Enter ­ . 29 [X] |PLU Group Code| [ST] Character Entries [ST] (1 to 99) (See NOTE) * [AT/TL] Repeat for other groups * (For sequentially programming Group Codes (max. 99 groups) and Names, the code specification can be skipped.) ex.) To set “BEER” for a PLU group 2 Mode Lock: SET Enter 29, depress [X]. 2 [ST] BEER [ST] [AT/TL] Journal Print P29 PLU GROUP 02 BEER 0050 16:52TM NOTE: A maximum of 16 regular-sized characters may be set for each PLU Group name. One double-sized character occupies two regular-sized characters’ space. Also see the CHARACTER ENTRIES at the beginning of this chapter. If no name is programmed for a PLU Group, an auto-preset data is assigned as the PLU Group Name (PLU GPxx; xx = PLU Group Code 01 to 99). 5-38 5. PROGRAMMING OPERATIONS EO1-11138 5.4 How to Access a Program Item n RKP Message Programming (Submode 30) This programming is used to set 20 RKP messages (a maximum of 20 characters x 2 lines for each), and also used to designate an RKP on which each message is outputted. If your printer is the TM-300, you can select a color for each message. CONDITION OPERATION Any time outside a sale When you enter 30 and depress the [X] key, the screen shown below will appear. Mode Lock: SET * SET * 02-06-1999 12:34 30 [X] |Message No.| [NS] 1 [ST] PROGRAMMING RKP MESSAGE 01 02 03 04 05 06 07 . 08 Please input item No. 0.00 Pg up Pg dw Enter ­ . |1st Line Message Entries| [ST] Max. 20 characters Initial Setting: Blank for all characters 2 [ST] 3 [ST] 4 [ST] |2nd Line Message Entries| [ST] Max. 20 characters Initial Setting: Blank for all characters |RKP No. of the destination| [#] Max. 4 digits: Multiple RKPs are selectable. (NOTE 2 below) Initial Setting: RKP No. 1 |Color| [#] 0: Black (Initial Setting) 1: Red 1 to 20 Repeat for another message. [AT/TL] ex.) To set the following to the RKP message 1. Journal Print • 1st Line: 20 RKP MESSAGES ARE • 2nd Lin...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории