Войти:
Скачали: 7   Размер: 42 kb   Производитель: Bryant  
Категория: Термостаты
@name

Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage thermostat. Recognize safety information. This is the safety-alert symbol . When you see this symbol on the equipment and in the instruction manual, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most seriou

Скачали: 2   Размер: 53 kb   Производитель: Bryant  
Категория: Термостаты
@name

HEAT AUTOFAN AUX. HEAT * Air Conditioner Model * Heat Pump Model (HH07AT212) (HH07AT214) NON-PROGRAMMABLE THERMOSTAT ® * Standard Model (AC, HP, 2S) PROGRAMMABLE THERMOSTAT AND THERMIDISTATTM CONTROL ® * Standard Model (AC, HP, 2S) * Dual Fuel Model (DF) * ThermidistatTM Control Model (RH) The Bryant electronic thermostat product line consists of programmable and non-programmable air conditioner, heat pump, and 2-speed models; a programmable dual fuel model, and a programmable ThermidistatTM Con

Скачали: 0   Размер: 56 kb   Производитель: Bryant  
Категория: Термостаты
@name

To ensure the schedules are properly followed, make sure that AM or PM is correct for the time chosen. When the correct time is shown, press the End button to exit the Set Time mode. V. RESET FILTER The Reset Filter function is used to clear the “Clean Filter” icon on the display screen. The Reset Filter function is initiated by pressing the Hold and Occupied buttons simultaneously. The “Clean Filter” icon reminds the user when it is time to change or clean the filter of the unit. VI. PROGRAMMIN

Скачали: 0   Размер: 56 kb   Производитель: Bryant  
Категория: Термостаты
@name

GENERAL Bryant’s 7-day, commercial, programmable thermostats are wall-mounted, low-voltage thermostats which maintain room temperature by controlling the operation of an HVAC (heating, ventilation, and air conditioning) system. Separate heating and cooling set points and auto-changeover capability allow occupied and unoccupied programming schedules for energy savings. All thermostats allow up to 4 time and temperature settings to be programmed per 24-hr period. Each thermostat stores programs fo

Скачали: 1   Размер: 64 kb   Производитель: Bryant  
Категория: Термостаты
@name

TO ADJUST: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 01. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 01 setting. 4. Use up and down buttons to move between the available Option 01 values of 1 to 9. Factory default is 3. 5. Press MODE button again to return to Option 01. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to e

Скачали: 3   Размер: 64 kb   Производитель: Bryant  
Категория: Термостаты
@name

When disabled, AUTO icon does not appear when successive presses of MODE button are used to move between OFF, HEAT, and EHEAT (in heat pump systems). Factory default is ON (AUTO mode enabled). TO SELECT: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 15. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 15 setting. 4. Use up and down buttons to move between available Option 15 choices o

Скачали: 0   Размер: 65 kb   Производитель: Bryant  
Категория: Термостаты
@name

IX. LIGHT SENSOR ADJUSTMENT The light sensor is used for light-activated operation. The sensor can be adjusted for a variable degree of sensitivity. The sensitivity adjustment screw is located on the inner cover of the thermostat, near the DOWN ARROW button. Turning the screw clockwise increases the sensitivity of the sensor to light. Turning the screw counterclockwise decreases the sensitivity of the sensor to light. To check for correct sensitivity, place the thermostat in Program On mode. The

Скачали: 7   Размер: 125 kb   Производитель: Bryant  
Категория: Термостаты
@name

11—Two-Speed Heat Pump ® Fig. 12—Two-Speed Heat Pump with Single-Stage Furnace with 2-Stage or Variable-Speed Furnace —Model 2S Thermostat —Model 2S Thermostat —9— MODEL 2S SINGLE-SPEED THERMOSTAT EASY SELECT HEAT PUMP TERMINAL BOARD MODEL 2S TYPICAL TWO-SPEED THERMOSTAT FAN COIL HEAT PUMP 24 VAC HOT FAN HEAT STAGE 3 COOL/HEATSTAGE 2 RVS COOLING COOL/HEATSTAGE 1 R G W/W1 Y/Y2 O/W2 Y1/W2 R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y2 C W2 R O Y1 W3 See notes 3, 7, 8, 9, and 11 W2 Y

Скачали: 0   Размер: 173 kb   Производитель: Bryant  
Категория: Термостаты
@name

Cooling Operation 1. Press H/C button until COOL is displayed. 2. Press DOWN button until LCD readout reads 3_/1.7_C below room temperature. Press UP and FAN buttons simultaneously to defeat timers. Cooling system should begin to operate immediately. Table 1 shows the thermostat outputs for each available stage of heating or cooling. It may be useful in checkout or troubleshooting. T1PAC/ T1PHP 3 Table 1 – Outputs T1PAC/ T1PHP EQUIPMENT HEAT CONFIGURATION EM HEAT STAGE 2 OPTION #1 Y,G,W W HP, PH

Скачали: 0   Размер: 173 kb   Производитель: Bryant  
Категория: Термостаты
@name

1 INSTALLATIONCONSIDERATIONS ................... 1 INSTALLATION .................................... 1 Step1—ThermostatLocation ........................ 1 Step2—InstallThermostat ........................... 2 Step3—SetThermostatConfiguration ................. 2 Step4—UnderstandThermostatOperation .............. 2 Step5—CheckThermostatOperation .................. 3 WIRINGDIAGRAMS ................................ 4 SAFETY CONSIDERATIONS Read and follow manufacturer instructions carefully. Follow a





Категории