Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Honeywell, модель ML-50

Производитель: Honeywell
Размер: 1.2 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


two seconds interval in each line. Analyzer Output format adapted to GLP, GMP and ISO info 1 or info 2 Calibration report is printed at "Calibration of the Weighting Sensor" and "Calibration of Drying Temperature". AD-8121B MODE 3 Dump print (Received data is printed as it is) 1: Factory settings A & D .........Manufacture MODEL MX-50 .........Model S/N K1234567 .........Serial number ID LAB-123 .........ID number DATE 2004/09/30 .........Date TIME 13:57:24 .........Time CALIBRATED } Calibration type WEIGHT CAL.WEIGHT 20.000 g } Calibration mass SIGNATURE .........Signature 58 MS-70 / MX-50 / MF-50 / ML-50 12.3. Calibration of Drying Temperature (for MS-70 and MX-50) 12.3. Calibration of Drying Temperature (for MS-70 and MX-50) The temperature calibrator (accessory AX-MX-43) adjusts the drying temperature on the pan. Put the sensor on the pan and input measurement data at 100°C and 160°C. Each adjustment needs fifteen minutes. The buzzer sounds at the end. t-Up is displayed after no adjustment for five minutes during the operation and calibration is stopped. Press any key to return to weighing mode. Refer to the instruction manual of the certified temperature calibrator (accessory AX-MX-43). 12.3.1. Operation Thermometer Sensor pan 1. Replace the weighing pan with the sensor pan of the temperature calibrator. 2. Curve the sensor wire so it does not touch the heater cover and glass-housing when closing heater cover. Level the sensor pan. Do not leave a gap between the pan support and the sensor. Leave no gap Leave no gap Level the sensor pan. Curve the sensor wire so as not to touch heater cover. Leave no gap Sensor pan 3. Turn on the analyzer. 0. 000g Display the gram unit (of the weighing mode) 4. Press and hold the PROGRAM key 5. Press the SELECT key to display t-Cal . t-Cal 6. Press the ENTER key. 7. Press the START key to start the 100°C measurement. 15 min. Buzzer 8. After fifteen minutes, the buzzer sounds and blinks "1"0"0°C . Adjust the blinking value to the 100. "1"0"0. thermometer value using the v or ^ key. (Example: 97°C) 100. "9"7. 9. Press the ENTER key to store the new data and 15 min. to start the 160°C measurement. MS-70 / MX-50 / MF-50 / ML-50 59 Buzzer 10. After fifteen minutes, the buzzer sounds and the display 160. "1"6"0. blinks "1"6"0°C . Adjust the blinking value to the thermometer value using the v or ^ key. (Example: 162°C) 160. "1"6"2. 11. Press the ENTER key to store the new data, to finish the adjustment and to return to the weighing mode. If the report for GLP, GMP and ISO is output, glp is displayed. Output condition is selected in the function table. glp end 0. 000g When the heater cover is opened during measurement or the STOP key is pressed, calibration is stopped and the 0. 000ganalyzer displays the weighing mode. Calibration Report Example for Temperature Sensor Adapted to GLP, GMP and ISO Preset the following parameters to print data to AD-8121B Device Parameter Description Interval pU5e 1 1 Approx. two seconds interval in each line. Analyzer Output format adapted to GLP, GMP and ISO info 1 or info 2 Calibration report is printed at "Calibration of the Weighting Sensor" and "Calibration of Drying Temperature". AD-8121B MODE 3 Dump print (Received data is printed as it is) 1: Factory settings A & D .........Manufacture MODEL MX-50 .........Model S/N K1234567 .........Serial number ID LAB-123 .........ID number DATE 2004/09/30 .........Date TIME 12:34:56 .........Time CALIBRATED } Calibration type TEMPERATURE TARGET ACTUAL 100C 97C .........100°C target value measurement value 160C 162C .........160°C target value measurement value SIGNATURE .........Signature 60 MS-70 / MX-50 / MF-50 / ML-50 13. Function Table 13. Function Table The function table can store the following parameters to control the analyzer. Details of the Function Table Item and Display Symbol Param- eter Description Clock Cl adj Set date and time for the built-in clock. Refer to "5.2. Setting the clock and calendar" 0 1 Dot " . "Decimal point dp 1 Comma " , " Select decimal point of data. 0 1 Key mode Data is output by the ENTER key 1 Auto print mode Data is output after measurement. Data output mode prt 2 Stream mode Data is output continuously during measurement. 0 1 Not used.Data memory function data 1 Data is stored at each measurement 0 1 Moisture content is output.Form selection 5-d 1 Moisture content and temperature are output. 2 0 Continuous outputInterval pU5e 1 1 Output with approx. two seconds interval in each line. 0 1 Not used 1 To output (print) items with "analyzer information", "measurement program", "measurement data" and ""signature space" at one time. 3 Output format adapted to GLP, GMP and ISO info 2 To output (print) items specified from "analyzer information", "measurement program" and "signature space". 4 Output of calibration report. 5 ID number id Set ID number. Used for the calibration report. Factory settings Clr Resets the analyzer to the factory settings. 1: Factory settings 2...

Эта инструкция также подходит к моделям:
Термостаты - MF-50 (1.2 mb)
Термостаты - ML-50 (1.2 mb)
Термостаты - MF-50 (1.2 mb)
Термостаты - MS-70 (1.2 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории