Инструкция по эксплуатации Aube Technologies, модель TH113

Производитель: Aube Technologies
Размер: 579.74 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


Temperature control: AF (ambient with floor limit) / A (ambient) • Install the master thermostat in the controlled area. • Choose a location about 5 ft. above the floor in an area where the temperature is stable. • Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes. Temperature control: F (floor) • Can be installed anywhere. • Wire the 12 VDC base to the nearest slave unit. The floor sensor must be installed in an area where average temperature can be read. The cable must follow the wall down to the floor and must not cross any heater wires or be directly on or adjacent to a heating wire. For maximum performance, the sensor probe should be centered between the wires in the mat (max. 80°C). • Push the excess wire into the wall, secure the base using the provided screws and wall anchors, and install the TH11x thermostat onto the base. • Once the thermostat is installed, return power to heating system and slave units and the master thermostat to ON. 3.4 Slave Units - GFCI Test We recommend you test the GFCI immediately after installing the thermostat, and once a month thereafter to ensure iting properly. If the test warning light comes ON dsystem from the main power panel he installation. • Slide the protective door upwards and make sure the switch is ON. is ope normal operation, cut power to heating • Press TEST. • The test is successful if the TEST warning light is ON and power is cut off. • If the test fails (first installation test): a. Verify installation b. Check the load wires c. Once you've identified the problem, run the GFCI test again • If the test fails (monthly maintenance): a. Cut power to heating system from the main power panel and call customer service • When the test is successful, reset the slave unit by switching from ON to STANDBY then back to ON. • Repeat steps 1 to 3 for all slave units. Technical Specifications Temperature: - Operation: 32°F to 122°F (0°C to 50°C) - Storage: -4°F to 122°F (-20°C to 50°C) TH113/TH114/TH115/TH116 (A/F/AF-12VDC) Power supply 12 V from remote unit Maximum up to 10 slave units per slave units master thermostat Wire gauge 20 AWG Size (H • W • D) 4.63 x 2.7 x 0.61 in. BASE (117.5 x 68.3 x 15 mm) NOTE: Refer to the TH11x user guide for technical specifications. CT230-120GA/120GB/240GA/240GB Supply - PB112-120 1800 W @ 120 VAC 60 Hz, 15 A resistive - PB112-240 3600 W @ 240 VAC 60 Hz, 15 A resistive GFCI GA=5 mA / GB=30 mA Certification c CSA us Size (H • W • D) 4.63 x 2.7 x 1.45 in. BASE (117.5 x 68.3 x 37 mm) Size (H • W • D) 4.67 x 2.74 x 0.67 in. INTERFACE (118.6 x 69.6 x 17 mm) Warranty Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions,...

Эта инструкция также подходит к моделям:
Термостаты - CT230-120GB (579.74 kb)
Термостаты - TH114 (579.74 kb)
Термостаты - CT230-120GA (579.74 kb)
Термостаты - CT230-240GA (579.74 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории