Производитель: A&D
Размер: 1.2 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Display gram unit (of the weighing mode). PROG 1 0. 000g Select a Program Number to Edit the Measurement Program 2. Press the PROGRAM key and press the v or ^ key to select a program number. 3. Press the ENTER key to use the number. 4. The analyzer displays end and returns to the weighing mode. PROG "4Program number Caution If the data memory function is active, the data end memory number (MEM) is displayed in place of the PROG 4 0. 000g program number (PROG). MS-70 / MX-50 / MF-50 / ML-50 35 Select an Analysis Mode 5. Press the SELECT will blink. Select U-t key to select a symbol, it of the timer mode with the v or ^ key. (Press these keys to select it) Set the Heating Pattern 6. Select drying temperature with the SELECT key. Select ramp drying of the heating pattern with the PROGRAM key. Set the Final Drying Temperature 7. Set 160°C with the v or ^ key. Set the Ramp Time8. Set 5.0 minutes with the v or ^ key. Set the Analysis Time 9. Set 10.0 minutes with the v or ^ key. Set a Measurement Unit 10. Select a measurement unit with the SELECT key. Select moisture content (based on a wet Set the Minimum Scale Value of the % Display SELECT key. Select 0.01 [%] with the v or ^ key. Set the Minimum Scale Value of the Gram Display SELECT key. Select 0.001 [g] with the v or ^ key. Store the Parameters and Finish the Operation key to store the new parameters of the measurement program to program number 4. Pressing the key, the weighing mode is automatically displayed. When PROG 4 is recalled, To cancel the new parameters and return to the RESET key. "U"-"t 0.000g Analysis mode 1 0.000g "1"0"5°C Ramp Time "5."0 min 2 0"% "M"O"I"S"T "/"W Measurement unit "0."0"1% Minimum scale value of % display "0."0"0"1g Minimum scale value of gram display 0.000g160°C 10.0 min "1"0."0 min Analysis time 0.000g "1"6"0°C Final drying temperature Ramp drying Gram display of weighing mode sample ) with the v or ^ key. 11. Select the % display with the 12. Select gram display with the 13. Press the ENTER the settings can be used. weighing mode, press the 36 MS-70 / MX-50 / MF-50 / ML-50 7.2.3. Step Drying (ML-50 can not select step drying) Standard Mode, Automatic Mode or Manual Mode Refer to page 39 for Timer Mode This explanation uses the following parameters and sample displays of MX-50. Drying temperature 2 Drying temperature 1 Time Stage 1 Stage 2 "Temperature 1" can be set higher than "temperature 2" in step drying. Common Items Program number ..........................................5 ( PROG 5 ) Drying program Heating pattern....................Step drying ( ) Drying temperature 1 ..........120°C Drying temperature 2 ..........160°C Time.....................................5.0 minutes Measurement Unit..............................................Moisture content % D MOIST /W/DMinimum scale value during measurement ..0.01 % Minimum scale value of gram display...........0.001 g Sample quantity............................................Approximately 5 g Data memory function ..................................Not used Items for Standard Mode Analysis mode ..............................................Standard mode (Symbol: 5td ) ACCURACY .................................................MID. Analyzing mode to finish measurement............Automatic setting by ACCURACY Items for Automatic Mode Analysis mode ..............................................Automatic mode (Symbol: U-a ) Analyzing mode to finish measurement............0.05 %/min Items for Manual Mode Analysis mode ..............................................Manual mode (Symbol: U-m ) PROG 1 1. Display gram unit (of the weighing mode). 0. 000g Select a Program Number to Edit the Measurement Program 2. Press the PROGRAM key and press the v or ^ key to select a program number. 3. Press the ENTER key to use the number. 4. The analyzer displays end and returns to the weighing mode. PROG "5Program number end Caution If the data memory function is active, the data PROG 5 memory number (MEM) is displayed in place of the 0. 000g program number (PROG). MS-70 / MX-50 / MF-50 / ML-50 37 Select an Analysis Mode 5. Press the SELECT key to blink a symbol, it will blink. Select an analysis mode using the v or ^ key. Analysis If standard mode is used, select 5td . If automatic mode is used, select U-a . If manual mode is used, select U-m . Set ACCURACY for the Standard Mode 6. Select ACCURACY with the SELECT key. Select MID. with the v or ^ key. When ACCURACY is selected, HI, MID. or LO blinks. Set the Heating Pattern 7. Select drying temperature 1 with the SELECT key. Select step drying of the heating pattern with the PROGRAM key. Set Drying Temperature 1 8. Set 120°C to drying temperature 1 with key. Set 5.0 minutes with the v or ^ key. Set Drying Temperature 2 10. Select drying Temperature 2 with the SELECT key. Set 160°C with the v or ^ key. Set the Preset Termination Value for Automatic Mode Select a preset termination value with the key. Select 0.05 [%/min] with the v or ^ key. Select...

Эта инструкция также подходит к моделям:
Термостаты - MF-50 (1.2 mb)
Термостаты - ML-50 (1.2 mb)
Термостаты - MF-50 (1.2 mb)
Термостаты - MS-70 (1.2 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории