Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Barco, модель GRAPHICS 500 R9002930

Производитель: Barco
Размер: 6.14 mb
Название файла: 516cd3eb-84fa-4ce8-b59c-a86c8a9ac668.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The switching between the 2 modes can only be done 6 times and this only during the first 100 hours of the lamp lifetime (considering a dual lamp mode i.e. both lamps are used). Lamps replacement 1000Runtime (hours) Power Mode Switching 1500 (Full power mode) Power Mode Switching possible (max 6 times ! ) possible (max 6 times ! ) or 3000 (econmy mode) Image 10-5 Lamp power mode (projector considered to be running in dual lamp mode i.e. with both lamps on) Above considerations and numbers (lifetimes) are only valid when functioning in dual lamp mode (both lamps on) How to select a Power mode ? 1. Press MENU to activate the Tool bar 2. Press > to select the Lamp item 3. Press v to Pull down the Lamp menu 4. Use ^ or v to select Power Mode 5. Press > to pull down the menu 6. Use ^ or v to select the desired mode (image 10-6) 7. Press ENTER R5976367 BARCOIQGRAPHICS500 01/02/2007 10.LampMenu A dialog box is displayed. Confirm or cancel with Accept or Cancel (image 10-7) Image 10-6 Image 10-7 10.4 History How to view the history ? 1. Press MENU to activate the Tool bar 2. Press > to select the Lamp item 3. Press v to Pull down the Lamp menu 4. Use ^ or v to select History (image 10-8) 5. Press ENTER A textbox is displayed (image 10-9) Image 10-8 R5976367 BARCOIQ GRAPHICS 500 01/02/2007 10.LampMenu Image 10-9 10.5 Reset runtime When to reset the lamp runtime ? The lamp runtime should only be reset when placing a new lamp. WARNING: Lamp runtime reset as well as the lamp replacement can only be done by a Barco authorized technician. How to reset the lamp runtime in the iQ/iD ? 1. Press MENU to activate the Tool bar 2. Press > to select the Lamp item 3. Press v to Pulldown the Lamp menu 4. Use ^ or v to select Reset runtime 5. Press > to pull down the menu 6. Use ^ or v to select the lamp to be reset (image 10-10) 7. Press ENTER A dialog box is displayed (image 10-11) 8. Use ,the numeric keys on the remote, or the keypad to change the serial number of the lamp (serial number 0000000 will not be accepted). Image 10-10 R5976367 BARCOIQGRAPHICS500 01/02/2007 10.LampMenu Image 10-11 WARNING: Lamp runtime reset as well as the lamp replacement can only be done by a Barco authorized technician. How to reset the lamp runtime in the SIM5Plus? 1. Press MENU to activate the Tool bar 2. Press > to select the Lamp item 3. Press v to Pull down the Lamp menu 4. Use ^ or v to select Reset runtime 5. Press > to pull down the menu 6. Use ^ or v to select thelamptobe reset 7. Press ENTER A dialog box is displayed (image 10-12) 8. Use , the numeric keys on the remote, or the keypad to change the serial number of the lamp (serial number 0000000 will not be accepted). Image 10-12 WARNING: Lamp runtime reset as well as the lamp replacement can only be done by a Barco authorized technician. 10.6 Runtime warning What can be done ? When the lamp has reached a certain predetermined runtime , a warning message will be displayed on the screen. The lamp runtime warning can be set in a range from 30 to 200 hours. The runtime warning is displayed by default at 30 hours before end of lamp lifetime. R5976367 BARCOIQ GRAPHICS 500 01/02/2007 10.LampMenu How to set the lamp runtime warning? 1. Press MENU to activate the Toolbar 2. Press > to select the Lamp item 3. Press v to Pull down the Lamp menu 4. Use ^ or v to select Runtime warning (image 10-13) 5. Press ENTER A dialogbox is displayed (image 10-14) 6. Use , the numeric keys on the remote, or the keypad to change the runtime warning setting. Image 10-13 Image 10-14 WARNING: Lamp runtime reset as well as the lamp replacement can only be done by a Barco authorized technician. R5976367 BARCOIQGRAPHICS500 01/02/2007 10.LampMenu R5976367 BARCOIQ GRAPHICS 500 01/02/2007 11.Imagefilesmenu 11. IMAGE FILES MENU Overview • Load file • Auto Image • Edit file • Rename file • Copy • Delete • Forced file load 11.1 Load file Howtoloada file ? 1. Press MENU to activate the Tool bar 2. Press > to select the Image files item 3. Press v to Pull down the Image files menu 4. Use ^ or v to select Load (image 11-1) 5. Press ENTER A dialog box is displayed (image 11-2) 6. Use ^ or v to select the desired file Tip: For more info about the available image files and the specifications, see "Standard Image Files", page 127 7. Press ENTER The file is loaded and the image is adapted. Image 11-1 R5976367 BARCOIQGRAPHICS500 01/02/2007 11.Imagefilesmenu Image 11-2 In PiP mode, the files which may be loaded will be of the data type if the active window is a data window, or they will be of the video type if the active window is a video window. What to do if the image is not perfect ? If the displayed image is not correct after AutoImage or after selecting the best fitting file, go to the Edit menu, select the active file and change the settings. 11.2 Auto Image What can be done ? Auto Image creates the best suited image file for the connected source. It calculates/measures several source parameters : • Total pixels ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории