Фрагмент инструкции


Before you begin, make sure all parts shown are included with your product. PWV240/BK PP740 Description Qty. Part # A wall mount assembly 1 095-0545-GB B concrete anchor 2 590-0320 C retaining spacer 4 590-5005 D 1/4-20 x 13 mm flat head phillips screw 2 520-1209 E M4 x 10 mm phillips screw 4 504-9012 F M4 x 20 mm phillips screw 4 504-9020 G M6 x 12 mm phillips screw 4 520-1128 H #14 x 63.5 mm flat head wood screw 2 520-1202 I M6 x 20 mm phillips screw 4 520-9402 J M6 x 30 mm phillips screw 4 510-9109 K M5 x 6 mm phillips screw 5 520-1023 L #10 flat washer 4 540-9400 M hook bracket 1 095-P1346 N adapter plate 1 095-P1322 O #10-32 x 6 mm flat head phillips screw 1 520-1108 P cable tie 1 560-1725 Parts List Installation to Wood Stud Wall WARNING • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. • Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. • Never tighten in excess of 80 in. • lb (9 N.M.). • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended. • Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not UL approved). 1 Using a stud finder, locate and mark the edges of the wood stud used in mounting this product. Use of an edge to edge stud finder is highly recommended. Use a level to draw a vertical line down the center of the stud. Use wall plate as template to mark center of holes along the vertical line. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Attach wall mount (A) to wall using two #14 x 63.5 mm flat head wood screws (H) as shown. Skip to step 2 on page 6. A H WOOD STUD WALL WALL PLATE 4 of 20 ISSUED: 02-05-09 SHEET #: 202-9312-1 5 of 20 ISSUED: 02-05-09 SHEET #: 202-9312-1 Installation to Solid Concrete and Cinder Block Level and use wall plate as template to mark center of holes. Drill two 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (B) in holes flush with wall. Place wall mount (A) over anchors and secure with wood screws (H). Make sure wall mount is level, and tighten all fasteners. A H B WALL PLATE SOLID CONCRETE CINDER BLOCK 1 CUTAWAY VIEW INCORRECT CORRECT wall plate wall plate plaster/ dry wall plaster/ dry wall concrete concrete • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity. • Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor. • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. WARNING • Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. • Never tighten in excess of 80 in. • lb (9 N.M.). WARNING • Always attach concrete expansion anchors directly to load-bearing concrete. • Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer. WARNING 1 3 2 B Drill holes and insert anchors (B). Place plate (A) over anchors (B) and secure with screws (H). Tighten all fasteners. A H B concrete surface 6 of 20 ISSUED: 02-05-09 SHEET #: 202-9312-1 M L N K N E G N Attaching Adapter Plate to Screen with VESA® 200 x 100 or 200 x 200 Mounting Pattern Attach hook bracket (M) to adapter plate (N) using four M5 x 6 mm screws (K) and #10 washers (L) as shown. 2 FOR VESA® 200 x 100 MOUNTING PATTERN: Choose hole pattern as shown below. Attach adapter plate (N) to back of screen using four M4 x 10 mm screws (E) as shown below. *NOTE: If screw (E) gets less than three threads of engagement, attach adapter plate (N) to back of screen using four M4 x 20 mm screws (F) and four spacers (C) as indicated below. Skip to step 3 on page 9. FOR VESA® 200 x 200 MOUNTING PATTERN: Choose hole pattern as shown below. Attach adapter plate (N) to back of screen using four M6 x 12 mm scr...

Эта инструкция также подходит к моделям:
Телевизоры - PARAMOUNT PWV240/BK (928.38 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории