Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Miller Electric, модель 440

Производитель: Miller Electric
Размер: 492.48 kb
Название файла:

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


. If notified by the FCC about interference, stop using the equipment at once. . Have the installation regularly checked and maintained. . Keep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference. ARC WELDING can cause interference. . Electromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots. . Be sure all equipment in the welding area is electromagneticallycompatible. . To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. . Locate welding operation 100 meters from any sensitive electronic equipment. . Be sure this welding machine is installed and grounded according to this manual. . If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area. 1-4. Principal Safety Standards Safety in Welding and Cutting, ANSI Standard Z49.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126 Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, American Welding Society Standard AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126 National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3. Safe Practices For Occupation And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018. Cutting And Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. OM-193 696 Page 3 1-5. EMF Information 1-5. EMF Information Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting. To reduce magnetic fields in the workplace, use the following procedures: 1. Keep cables close together by twisting or taping them. 2. Arrange cables to one side and away from the operator. 3. Do not coil or drape cables around your body. 4. Keep welding power source and cables as far away from operator as practical. 5. Connect work clamp to workpiece as close to the weld as possible. About Pacemakers: Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended. OM-193 696 Page 4 OM-193 696 Page 5 SECTION 2 – INSTALLATION 2-1. Specifications Rated Output Max. Open Rated Input Amperage at Rated Output Model 100% 60% 45% 35% Circuit Voltage 230 V 380 V 400 V 520 V Dimension (mm) Weight (kg) 340 190 A 27.6 V 245 A 29.8 V - - 320 A 32.8 V 68 55 A 32 A 32 A 23 A 510 x 650 x 1010 105 440 290 A 31.6 V 375 A 35 V 420 A 36.8 V - - 78 80 A 47 A 47 A 34 A 600 x 730 x 1150 175 * While idling 2-2. Duty Cycle and Overheating Duty Cycle is percentage of 10 minutes that unit can weld at rated load without overheating. Exceeding duty cycle can damage unit and void warranty. WELDING AMPERES % DUTY CYCLE 600 500 400 300 30 40 50 60 70 80 90100 200 25 35 Rated Output 100 340 600 500 400 300 30 40 50 60 70 80 90100 700 25 35 Rated Output 200 440 WELDING AMPERES % DUTY CYCLE 3.5 Minutes Welding 6.5 Minutes Resting 4.5 Minutes Welding 5.5 Minutes Resting Overheating 0 15 A or V OR Minutes Reduce Duty Cycle 2-3. Volt-Ampere Curves The volt-ampere curves show the normal minimum and maximum voltage and amperage output capabilities of the unit. Bluthunder 340 Bluthunder 440 2-4. Positioning Jumper Links Check input voltage available at site. 1 Jumper Links Access Remove side panel. 2 Jumper Link Label Check label – only one is on unit. 3 Input Voltage Jumper Links Move jumper links...

Эта инструкция также подходит к моделям:
Сварочные аппараты - 340 (492.48 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории