Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Campbell Hausfeld, модель CHN10202

Производитель: Campbell Hausfeld
Размер: 3.07 mb
Название файла: 22b7095a-740e-4946-a624-a696d3b3c79d.pdf

Язык инструкции:enesfr

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


An inadequate air supply can cause a loss of power and inconsistent driving. 2. An oiler can be used to provide oil circulation through the nailer. A filter can be used to remove liquid and solid impurities which can rust or “gum up” internal parts of the nailer. 3. Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source if a regulator fails, or 150 psi, whichever is greater. Use 3/8” air hose for runs up to 50’. Use 1/2” air hoses for 50’ run or longer. For better performance, install a 3/8” quick plug (1/4” NPT threads) with an inside diameter of .315” (8mm) on the nailer and a 3/8” quick coupler on the air hose. 4. Use a pressure regulator on the compressor, with an operating pressure of 0 - 125 psi. A pressure regulator is required to control the operating pressure of the nailer between 60 and 100 psi. OPERATIONAL MODE Always know the operational mode of the nailer before using. Failure to know the operational ger. The nailer MUST NOT OPERATE. Do not use the tool if it operates without pulling the trigger. Personal injury may result. 6. Remove the nailer from the work surface. The Work Contact Element (WCE) must return to its original down position. The nailer MUST NOT OPERATE. Do not use the tool if it operates while lifted from the work surface. Personal injury may result. 7. Pull the trigger and depress the work contact element (WCE) against the work surface. The nailer MUST NOT OPERATE. 8. Depress the Work Contact Element (WCE) against the work surface. Pull the trigger. The nailer MUST OPERATE. An improperly functioning tool must not be used. Do not actuate the tool unless the tool is placed firmly against the work piece. LOADING/UNLOADING THE NAILER 1. Always connect the tool to the air supply before loading fasteners. 2. Push down on the latch. Pull back on the magazine cover. 3. Insert a stick of Campbell Hausfeld nails or equivalent (see "Fasteners" section) into the magazine. Make sure the pointed ends of the nails are resting on the bottom ledge of the magazine when loading. Make sure the nails are not dirty or damaged. mode could result in death or serious personal injury. SINGLE SEQUENTIAL MODE This mode requires the trigger to be pulled each time a nail is driven. The nailer can be actuated by depressing the WCE against the work surface followed by pulling the trigger. The trigger must be released to reset the tool before another nail can be driven. OPERATING A SEQUENTIAL TRIP NAILER Check the operation of the Work Contact Element (WCE) trip mechanism before each use. The WCE must move freely without binding through its entire travel distance. The WCE spring must return the WCE to its fully extended position after being depressed. Do not operate the nailer if the WCE trip mechanism is not operating properly. Personal injury may occur. 1. Disconnect the air supply from the nailer. 2. Remove all nails from the magazine (see Loading/ Unloading). 3. Make sure the trigger and work contact element (WCE) move freely up and down without sticking or binding. 4. Reconnect air supply to the nailer. 5. Depress the Work Contact Element (WCE) against the work surface without pulling the trig- Operating Instructions CHN10202 4 60 psi Min. 100 psi Max. 150 psi or greater 3/8” I.D. BUILT TO LAST BUILT TO LAST BUILT TO LAST BUILT TO LAST BUILT TO LAST movement BUILT TO LAST BUILT TO LAST BUILT TO LAST BUILT TO LAST 1 2 BUILT TO LAST BUILT TO LAST 1 2 BUILT TO LAST BUILT TO LAST Latch BUILT TO LAST BUILT TO LAST 1 2 BUILT TO LAST BUILT TO LAST 1 2 BUILT TO LAST BUILT TO LAST Pestillo BUILT TO LAST movemiento Gire Como usar la Clavadora (Continuacion) 1. Desconecte la clavadora de la fuente de suministro de aire para lubricarla. 2. Gire la clavadora de modo que la entrada de aire quede mirando hacia arriba. Agregue de 4 a 5 gotas de aceite sin detergente 30W en la entrada de aire. No use aceites con detergentes, aditivos de aceite, ni aceites para herramientas neumaticas. Los aceites para herramientas neumaticas contienen solventes que pueden averiar los componentes internos de la clavadora. 3. Despues de agregar aceite, haga funcionar la clavadora brevemente. Limpie todo exceso de aceite que salga del escape de la tapa. CONEXION RECOMENDADA La ilustracion de abajo le muestra la conexion recomendada para la clavadora. 1. El compresor de aire debe tener la capacidad de suministrar un minimo de 4,14 bar cuando la clavadora este en uso. Si el suministro de aire es inadecuado podria haber perdida de potencia y falta de consistencia en el funcionamiento. 2. Puede utilizar un lubricador para lubricar la clavadora. Igualmente, puede utilizar un filtro para remover las impurezas liquidas y solidas que podrian oxidar u obstruir las partes BUILT TO LAST elemento de contacto antes de cada uso. El elemento de contacto se debe desplazar libremente, sin pegarse, a lo largo del area de desplazamiento. El resorte del elemento de contacto d...

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории