Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Trane, модель 100

Производитель: Trane
Размер: 646.12 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub. No. 22-1682-05-0802 (EN) Performance Data *UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 1.5 LOW (350 CFM/TON) ON ON OFF ON CFM WATTS 575 65 575 90 575 125 550 155 - NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS 640 70 640 110 640 140 630 175 - HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 700 85 700 125 700 160 700 200 - 2.0 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 700 100 700 130 700 170 700 210 - NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 800 115 800 155 800 200 800 250 - HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 900 140 900 195 900 240 900 290 - 2.5 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 875 130 875 180 875 230 875 270 - NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1000 175 1000 235 1000 285 1000 335 900 310 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1125 235 1125 295 1125 345 1100 370 925 318 3 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1050 195 1050 260 1050 305 1050 350 920 315 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1200 275 1200 330 1200 385 1100 385 940 330 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1325 360 1325 425 1300 460 1175 425 1000 365 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. *UY060R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 2nd Stage Capacity = 37,000 56,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEATING 1ST STAGE LOW ON ON CFM TEMP. RISE WATTS 600 57 85 600 57 110 600 57 155 600 57 190 - MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 700 49 90 700 49 130 700 49 175 700 49 210 - NORMAL ** ON OFF CFM TEMP. RISE WATTS 775 44 105 775 44 155 775 44 195 775 44 240 - HIGH OFF OFF CFM TEMP. RISE WATTS 870 39 135 870 39 185 870 39 235 870 39 290 - HEATING 2ND STAGE LOW ON ON CFM TEMP. RISE WATTS 860 61 140 920 57 200 920 57 245 920 57 300 670 79 245 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1000 53 190 1000 53 255 1000 53 305 1000 53 340 700 75 255 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1125 47 250 1125 47 315 1125 47 370 1025 51 355 775 68 285 HIGH OFF OFF CFM TEMP. RISE WATTS 1250 42 340 1250 42 405 1250 42 445 1100 48 390 1000 53 355 NOTES: * First letter may be "A" or "T" ** Factory setting Pub. No. 22-1682-05-0802 (EN) 7 Performance Data TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRFLOW SETTING (See Notes) DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.0 LOW (350 CFM/TON) ON ON OFF ON CFM WATTS 750 84 750 122 750 154 720 185 710 221 NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS 840 109 840 146 840 181 840 226 820 264 HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 940 136 940 177 940 215 940 274 940 318 2.5 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 850 113 850 150 870 200 890 250 890 295 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 960 150 990 200 1000 230 1020 305 1010 350 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1080 195 1110 255 1120 315 1120 365 1080 390 3.0 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1020 175 1020 225 1040 280 1050 330 1050 375 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1170 240 1180 300 1200 365 1200 415 1130 420 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1290 310 1320 410 1350 470 1340 520 1150 440 3.5 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1170 250 1190 315 1210 370 1210 435 1100 405 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1360 365 1390 445 1400 500 1360 535 1210 475 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1360 355 1390 450 1400 520 1350 535 1180 460 NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position. 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. TUY080R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 2nd Stage Capacity = 49,000 73,000 AIRFLOW SETTING DIP SWITCH ...

Эта инструкция также подходит к моделям:
Электрообогреватели - 120R9V (646.12 kb)
Электрообогреватели - 080 (646.12 kb)
Электрообогреватели - XV 90 (646.12 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории