Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Central Pneumatic Air Compressor, модель 94446

Производитель: Central Pneumatic Air Compressor
Размер: 742.15 kb
Название файла: 94446.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Wear an ANSI-approved dust mask or respirator when working around metal, wood, and chemical dusts and mists. REV 06k Do not overreach8. . Keep proper footing and balance at all times. Do not reach over or across running machines or air hoses. Maintain tools with care9. . Keep tools clean for better and safer performance. Follow instructions for lubricating and changing accessories. Inspect tool cords and air hoses periodically and, if damaged, have them repaired by a qualified technician. The handles must be kept clean, dry, and free from oil and grease at all times. Disconnect air supply10. . Disconnect air hose when not in use. Remove adjusting keys and wrenches11. . Check that keys and adjusting wrenches are removed from the tool or machine work surface before plugging it in. Avoid unintentional starting12. . Do not carry any tool while holding the trigger, whether it is plugged in or not. Stay alert13. . Watch what you are doing, use common sense. Do not operate any tool when you are tired. Check for damaged parts14. . Before using any tool, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts; any broken parts or mounting fixtures; and any other condition that may affect proper operation. Any part that is damaged should be properly repaired or replaced by a qualified technician. Do not use the tool if any switch does not turn On and Off properly. Guard against electric shock15. . Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures. Replacement parts and accessories16. . When servicing, use only identical replacement parts. Use of any other parts will void the warranty. Only use accessories intended for use with this tool. Approved accessories are available from Harbor Freight Tools. Do not operate tool if under the influence of alcohol or drugs17. . Read warning labels if taking prescription medicine to determine if your judgement or reflexes are impaired while taking drugs. If there is any doubt, do not operate the tool. Use proper size and type extension cord18. . If an extension cord is required for the air compressor, it must be of the proper size and type to supply the correct current to the tool without heating up. Otherwise, the extension cord could melt and catch fire, or cause electrical damage to the tool. Check your compressor’s manual for the appropriate size cord. Note: Performance of the compressor (if powered by line voltage) may vary depending on variations in local line voltage. Extension cord usage may also affect tool performance. Maintenance19. . For your safety, maintenance should be performed regularly by a qualified technician. Compressed air only20. . Never use combustible gases as a power source. Warning: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. Unpacking When unpacking, check to make sure the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at the number on the cover of this manual as soon as possible. Setup FloorStapler1/4”-18 NPTFor best service you should incorporate an oiler, regulator, and inline filter, as shown in the diagram above. Hoses, couplers, oilers, regulators, and filters are all available at Harbor Freight Tools. 1. Wrap the Air Inlet (37) with pipe thread seal tape (not included) before threading it into the Arm (30). Connect the 3/8” ID Air Source Hose to the Air Inlet (37). Note: If you are not using an automatic oiler system, before each use add a few drops of Pneumatic Tool Oil to the airline connection. Add a few drops more after each hour of continual use. 2. Set the air pressure on your compressor to between 60-125 PSI. Do not exceed the maximum air pressure of 125 PSI. 3. Check the air connection for leaks. Disconnect from the air source. REV 06k Loading the Tool Warning! Disconnect the Stapler from the air compressor whenever loading or servicing. After disconnecting the Stapler from the air compressor, there could still be enough air pressure to fire the Stapler. After the air compressor hose is disconnected, always fire the Stapler into a piece of scrap to make sure all of the air is expended. 1. Grip the Sleeve (78) and pull out the Magazine Cover (72). Caution: The Magazine Cover (72) may snap closed with force, sometimes without warning. 2. CleatsFIGURE 1Install fasteners: Cleats – Place the Cleats into the larger slot in the magazine so that the top of the cleat rests on the rail in the center of the magazine. See Figure 1, above. Staples – Place the staples over the center rail of the magazine. Note: Only use the fastener types and sizes listed on the Sp...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории