1. To drive the fastener shallower, rotate the depth setting wheel (L) to the right. 2. To drive a fastener deeper, rotate the depth setting wheel (L) to the left. CLEARING A JAMMED FASTENER Lock off trigger, disconnect air line from tool and remove fasteners from magazine before making adjustments or personal injury may result. Keep the tool pointed away from yourself and others. Serious personal injury may result. 1. Lock off trigger (NS100B only). 2. Disconnect air supply from tool. 3. Push the magazine release then slide magazine to open chamber. 4. Position stapler on a stable surface so contact trip is pointing upward and away from you. 5. Remove ALL fasteners in the top chamber of the magazine. 6. Remove bent fastener, using pliers if necessary. 7. If driver blade is in the down position, insert screwdriver or other rod into nosepiece and push driver blade back in position. 8. Reinsert fasteners into the top chamber of the magazine (see Loading the Tool). Fig. 3 Fig. 5 F E A NS150B NS150B A Fig. 2 NS100B NS100B MN o fig.4L 9. Slide magazine until it clicks, securing the magazine. 10. Reattach air supply. nOte: Should fasteners continue to jam frequently in nosepiece, have tool serviced by an authorized PORTER-CABLE service center. COlD WeAtheR OpeRAtiOn When operating tools at temperatures below freezing: 1. Make sure compressor tanks have been properly drained prior to use. 2. Keep tool as warm as possible prior to use. 3. Make certain all fasteners have been removed from magazine. 4. Lower air pressure to 80 psi or less. 5. Reconnect air and and load nails into magazine. 6. Actuate the tool 5 or 6 times into scrap lumber to lubricate o-rings. 7. Turn pressure up to operating level (not to exceed 120 psi) and use tool as normal. 8. Always drain the compressor tanks at least once a daily. hOt WeAtheR OpeRAtiOn Tool should operate normally. However, keep tool out of direct sunlight as excessive heat can deteriorate bumpers, o-rings and other rubber parts resulting in increased maintenance. BELT HooK (FIG. 1) The PORTER-CABLE nailers include an integrated belt hook (I) and can be rotated to either side of the tool to accommodate left or right handed users. It can also be rotated out of the way when not in use. If the hook is not desired at all, it can be removed from the tool. to remove belt hook: 1. Lock off trigger. 2. Disconnect the tool from air supply. 3. Using the appropriate hex wrench, remove the end cap screws from the end cap of the tool. 4. Remove the belt hook. 5. Replace end cap and gasket. Ensure that the three screws are tight. 6. Replace and tighten air fitting. MAINTENANCE Lock off trigger, disconnect air line from tool and remove fasteners from magazine before making adjustments or personal injury may result. DAILy MAINTENANCE CHART ACTIoN WhY hOW Drain compressor tanks Prevents accumulation Open petcocks or other and hoses daily. of moisture in comdrain valves on compressor pressor and nailer. tanks. Allow any accumulated water to drain from hoses. Clean magazine, magazine Permits smooth opera-Blow clean with compressor release and contact tion of magazine, reduces air. The use of oils, lubricants trip mechanism. wear and prevents jams. periodically or solvents is not recommended as they tend to attract debris. Before each use, check Prevents jams, leaks Tighten loose screws to insure all screws, and premature fail-or other fasteners using nuts and fasteners are ure of tool parts. the appropriate hex tight and undamaged. wrench or screwdriver. CLEANING Never use solvents or other harsh chemicals for cleaning the non-metallic parts of the tool. These chemicals may weaken the materials used in these parts. Use a cloth dampened only with water and mild soap. Never let any liquid get inside the tool; never immerse any part of the tool into a liquid. REpAIRS For assistance with your tool, visit our website at for a list of service centers, or call the PORTER-CABLE Customer Care Center at (888) 848-5175. SERvICE REpLACEMENT pARTS Use only identical replacement parts. For a parts list or to order parts, visit our website at servicenet. porter-cable.com. You can also order parts from your nearest PORTER-CABLE Factory Service Center or PORTER-CABLE Authorized Warranty Service Center. Or, you can call our Customer Care Center at (888) 848-5175. SERvICE AND REpAIRS All quality tools will eventually require servicing and/or replacement of parts. For information about PORTER-CABLE, its factory service centers or authorized warranty service centers, visit our website at or call our Customer Care Center at (888) 848-5175. All repairs made by our service centers are fully guaranteed against defective material and workmanship. We cannot guarantee repairs made or attempted by others. You can also write to us for information at PORTER-CABLE, 4825 Highway 45 North, Jackson, Tennessee 38305 - Attention: Product Service. Be sure to include all of the infor...

Эта инструкция также подходит к моделям:
Строительные пистолеты - NS100B (3.82 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории