Фрагмент инструкции


Air supply hoses shall have a minimum working pressure rating of 10.7 kgf/cm2G (150 PSIG) or 150 percent of the maximum pressure produced in the system whichever is higher. CAUTION: Low air output of the compressor, or a long or smaller diameter air hose in relation to the nailing frequency may cause a decrease in the driving capability of the tool. Lubrication To insure maximum performance, install an air set (oiler, regulator, air filter) as close as possible to the tool. Adjust the oiler so that one drop of oil will be provided for every 30 nails. When n ir et is not used, oil the tool with pneumatic tool Pneumatic tool oil oil by placing 2 (two) or 3 (three) drops into the air fitting. This should be done before and after use. For proper lubri- cation, the tool must be fired a couple of times after pneu- matic tool oil is introduced. Nose adapter CAUTION: Always lock the trigger and disconnect the hose before installing or removing the nose adapter. When nailing workpieces with easily-marred surfaces, use the nose adapter. It is stored in the holder on the reverse side of the magazine. Holder 4 Nose adapter Attach the nose adapter to the contact arm (see right). When not in use, store the nose adapter in the holder on the reverse side of the magazine to keep it from being lost. Contact arm 6' Nose adapter Loading nailer CAUTION: Always lock the trigger and disconnect the hose before loading the nailer. Select nails suitable for your work. Insert strip of nails into the magazine. Pull the pusher lever to the rear to engage the pusher to the last nail. Unloading nailer CAUTION: Always disconnect the air hose before unloading the nailer. Pull the pusher lever to the rear. Return the pusher lever Pusher lever back while keeping the pusher depressed to disengage it from the strip of nails. Depress the nail stopper and remove the strip of nails from the magazine. Nail stopper Adjusting depth of nailing CAUTION: Always lock the trigger and disconnect the hose before adjusting the depth of nailing. To adjust the depth of nailing, turn the adjuster so that the arrow above the adjuster will point to the number indicated on the adjuster. The depth of nailing is the deepest when the arrow points to the number 1. It will become shallower as the arrow points to higher number. The depth can be changed in approx. 1.0 mm (1132”) increments per gradua- tion. If nails cannot be driven deep enough even when the arrow points to the number 1, increase the air pressure. If nails are driven too deep even when the arrow points to the number 9, decrease the air pressure. Generally speaking, the tool service life will be longer when the tool is used with lower air pressure and the adjuster set to a lower number. Connecting air hose Lock the trigger. Slip the air socket of the air hose onto the Air socket \ air fitting on the nailer. Be sure that the air socket locks firmly into position when installed onto the air fitting. A hose coupling must be installed on or near the tool in such a way that the pressure reservoir will discharge at the time the air supply coupling is disconnected. I I Operation CAUTION: Make sure all safety systems are in working order before operation. 1) To drive a nail, you may place the contact element against the workpiece and pull the trigger, or 2) Pull the trigger first and then place the contact element against the workpiece. No. 1 method is for intermittent nailing, when you wish to drive a nail carefully and very accurately. No. 2 method is for continuous nailing. 12 / // // / I -&.& For No. 1 method, set the change lever to the “Intermittent Nailing” position. For No. 2 method, set the change lever to the Continuous nailing “Continuous Nailing” position. After using the change lever to change the nailing method, always make sure that the change lever is properly set to the position for the desired nailing method. @!-Change lever Trigger lock Anti dry fire mechanism This tool is equipped with an anti dry fire mechanism. When there are a few nails remaining in the magazine, the contact arm will be locked in the undepressed position to prevent the tool from being activated. Load more nails to resume operation. Jammed nailer CAUTION: Always lock the trigger, disconnect the hose and remove the nails from the magazine before cleaning a jam. When the nailer becomes jammed, do as follows: Insert a small rod or the like into the ejection port and tap it with a hammer to retract the driver. Use pliers to bend the jammed nail so that the nail head comes out of the slot in the driver guide. Then remove the iammed nail. Hammer H Small rod Ejectionport Driver Nails Handle nail strips and their box carefully. If the nail strips have been handled roughly, they may be out of shape or their connector breaks, causing poor nail feed. Avoid storing nails in a very humid or hot place or place exposed to direct sunlight. 1s MAINTENANCE CAUTION: Always disconnect the hose before attempting to perform inspection or mainten...

Эта инструкция также подходит к моделям:
Строительные пистолеты - AN922 (1.23 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории