Войти:
Оценок - 6, средний балл: 4 ( )

Инструкция по эксплуатации Alliance Laundry Systems, модель 100

Производитель: Alliance Laundry Systems
Размер: 1.22 mb
Название файла: 42f8c555-4719-4ed4-8f0f-b05ef7069a5c.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


(102 mm) 6 in. (152 mm) 7 in. (177.8 mm) 8 in. (203 mm) 10 in. (203 mm) 12 in. (305 mm) Table 4 9001000 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 45 Installation Water Connection WARNING To avoid personal injury, recommended inlet water temperature should be nohigher than 125° Fahrenheit (51° Celsius). W709 The 18-135 models are delivered with hoses with 3/4 inch hose connectors. The 165 model is delivered with 3 x 1 inch and 1 x 3/4 inch hose connectors. These hoses fit the water inlet valves of the machine and the main water inlet taps. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 30-85 psi (2-5.7 bar). If the pressure is too low, the cycle time will increase considerably. In case of boiler fed machines, a maximum of hot water of 194°F (90°C) should be available: Connections should be supplied by a hot and a cold water line per national and local codes. To connect water service to machine with rubber hoses, use the following procedure: 1. Before installing hoses, flush the water system for at least two minutes. 2. Check filters in the washer-extractor’s inlet hoses for proper fit and cleanliness before connecting. 3. Hang the hoses in a large loop, do not allow them to kink. If additional hose length is needed use flexible hoses with screen filters. Each hose should have a screen filter installed to keep rust and other foreign particles out of the water inlet valves. Pressure of 30-85 psi (2-5.7 bar) provides best performance. Although the washer-extractor will function at lower pressures, increased fill times will occur with some loss of supply flushing. Suitable air cushions should be installed in supply lines to prevent “hammering.” Water Supply Information Model 18 25 33 35 40 55 75 100 135 165 200 Water inlet connection size 0.75 in. (19 mm) 0.75 in. (19 mm) 0.75 in. (19 mm) 0.75 in. (19 mm) 0.75 in. (19 mm) 0.75 in. (19 mm) 0.75 in. (19 mm) 0.75 in. (19 mm) 0.75 in. (19 mm) 1.0 in. (25 mm) 0.75 and 1.0 in. (19 and 25 mm) Number of 3 3 3 3 3 3 3 4 4 4 4 water inlets (standard) Recommended pressure 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) 30-85 psi (2-5.7 bar) Inlet flow capacity 5.3 gal/ min (20 l/ min) 5.3 gal/ min (20 l/ min) 5.3 gal/ min (20 l/ min) 5.3 gal/ min (20 l/ min) 5.3 gal/ min (20 l/ min) 12 gal/ min (45 l/ min) 12 gal/ min (45 l/ min) 12 gal/ min (45 l/ min) 12 gal/ min (45 l/ min) 25 gal/ min (95 l/ min) 25 gal/ min (95 l/ min) Table 5 46 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 9001000 Installation Electrical Installation WARNING Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive. W359 WARNING Hazardous Voltage. Can cause shock, burn or death. Verify that a ground wire from a proven earth ground is connected to the lug near the input power block on this machine. W360 The AC inverter drive requires a clean power supply free from voltage spikes and surges. A voltage monitor should be used to check incoming power. The customer’s local power company may provide such a monitor. If input voltage measures above 240V for a 220V drive or above 480V for a 400V drive, ask the power company to lower the voltage. As an alternative, a step-down transformer kit is available from the distributor. The AC drive provides overload protection for the drive motor. However, a separate single or three phase circuit breaker must be installed for complete electrical overload protection. This prevents damage to the motor by disconnecting all legs if one should be lost accidentally. Check the data plate on the back of the washer-extractor or consult Table 6 for circuit breaker requirements. IMPORTANT: Do NOT use fuses in place of a circuit breaker. DANGER Do not use a phase adder on any variable- speed machine. W490 The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. The connection should be shielded in a liquid tight or approved flexible conduit with proper conductors of correct size installed in accordance with the National Electric Code or other applicable codes. The connection must be made by a qualified electrician using the wiring diagram provided with the washer- extractor, or according to accepted European standards for CE-approved equipment. Use wire sizes indicated in Table 6 for runs up to 50 feet. Use next larger size for runs of 50 to 100 feet. Use two sizes larger for runs greater than 100 feet. For personal safety and proper operation, the washer- extractor must be grounded in accordance with state and local codes. If such codes are not available, grounding must conform with the National Electric Code, article 250-95. The ground connecti...

Эта инструкция также подходит к моделям:
Стиральные машины - 165 (1.22 mb)
Стиральные машины - 18 (1.22 mb)
Стиральные машины - 200 (1.22 mb)
Стиральные машины - 33 (1.22 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории