Производитель: Goodman Mfg
Размер: 137.95 kb
Название файла: TM-MBVC.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


MBVC BLOWER SPECIFICATIONS H (3) KNOCKOUTS1.125 1.375 1.750 .875 KNOCKOUT (2 PLACES) 6 1/2 5 5 1/8 3 1/4 D W MBVC1200/1600/2000 MODEL Physical Information Dimensions, inches (mm) Shipping Weight lbs.(kg) Blower Wheel (D x W) Blower Motor (HP) MCA1 MOP1 W H D MBVC1200 10X8 1/2 4.3 15 17. (445) 26 (660) 21 (533) 72 (32.6) MBVC1600 10X8 3/4 6.3 15 21 (533) 30 (762) 21 (533) 82 (37.2) MBVC2000 11X10 3/4 5.8 15 24. (622) 30 (762) 21 (533) 94 (42.6) Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate for MCA and MOP with approved accessory heaters installed. MBVC BLOWER SPECIFICATIONS 5 BLOWER OPENING DIMENSIONS (TOP VIEW) MBVC1200/1600/2000 HKR HEATER DATA NO HEAT KIT HKR-03* HKR05-(C)* HKR-06* HKR-08(C)* MBVC 1200AA-1AA X X X X X 1600AA-1AA X X X X X 2000AA-1AA X X X X X ^ = Circuit 1: Single Phase for Air Handler Motor * = Revision level that my or may not be designated Circuit 2: 3-Phase for HKR3 Heater Kits C = Circuit Breaker option X = Allowable combinations ~ = Restricted combinations BLOWER HEATER KIT HKR-10(C)* HKR-15C* HKR-20C* HKR-21C* MBVC 1200AA-1AA X X ~ ~ 1600AA-1AA X X ~ ~ 2000AA-1AA X X X ~ ^ = Circuit 1: Single Phase for Air Handler Motor * = Revision level that my or may not be desig Circuit 2: 3-Phase for HKR3 Heater Kits C = Circuit Breaker option X = Allowable combinations ~ = Restricted combinations BLOWER HEATER KIT SMALL MEDIUM LARGE 13-1/4” 23-1/2” 11 - 5 / 1 6” 11” 20- 1/16” 11 -5/ 1 6 ” 10-7/8” 16-1/2” 10-1/4” BLOWER PERFORMANCE DATA HTR kW MBVC1200* MBVC1600* MBVC2000* SWITCH 9 SWITCH 10 SWITCH 11 3 600 800 800 ON ON ON 5 600 800 800 ON ON OFF 6 635 800 800 ON OFF ON 8 740 1000 1000 ON OFF OFF 10 1000 1000 1200 OFF ON ON 15 1400 1500 1500 OFF ON OFF 20 NR NR 2000 OFF OFF ON 21 NR NR NR ON^ ON^ ON^ ^ Factory setting MODEL LOW STAGE COOL HIGH STAGE COOL COOL SELECTION SWITCHES ADJUST SELECTION SWITCHES PROFILE SELECTION SWITCHES 1 2 3 4 5 6 MBVC1200 400 600 OFF OFF OFF OFF OFF OFF 540 800 ON OFF ON OFF ON OFF 670 1000 OFF ON OFF ON OFF ON 800 1200 ON ON ON ON ON ON MBVC1600 670 1000 OFF OFF OFF OFF OFF OFF 800 1200 ON OFF ON OFF ON OFF 940 1400 OFF ON OFF ON OFF ON 1070 1600 ON ON ON ON ON ON MBVC2000 800 1200 OFF OFF OFF OFF OFF OFF 1070 1600 ON OFF ON OFF ON OFF 1200 1800 OFF ON OFF ON OFF ON 1340 2000 ON ON ON ON ON ON Locate the blower speed selection DIP switches on the integrated control module. Select the desired “cooling” speed tap by positioning switches 1 and 2 appropriately. Select the desired “adjust” tap by positioning switches 3 and 4 appropriately. Refer to the following figure for switch positions and their corresponding taps. Verify CFM by counting the number of times the green CFM LED blinks. Normal* +10% -10% Normal 3 4 OFF ON OFF ON 3 4 OFF ON 3 4 OFF ON 3 4 Air flow Adjust Taps (*indicates factory setting) Thermostat "Fan Only" Mode During "Fan Only" operations, the CFM output is 30% of the maximum CFM capability. CFM Trim Adjust Minor adjustments can be made through the dipswitch combination of 3-4. WIRING DIAGRAMS THERMOSTATS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Y1 1 2 R C C Modular Blower Integrated Control Module Typical Two-Stage Cool, Two-Stage HeatThermostat Dehumidistat [Optional] G W1 W2 Y1 Y2 O Y2 W1 W2 Y1 Y2 Remote Condensing Unit (Two-Stage AC) NEU HOT DEHUM C R G R * Typical Two-Stage Cooling with Two-Stage Heating Y1 1 2 R C C Modular Blower Integrated Control Module Typical Two-Stage Cool, Two-Stage Heat Heat Pump Thermostat Dehumidistat [Optional] G W1 W2 Y1 Y2 O DEHUM R Y2 W2 Y1 Y2 Remote Condensing Unit (Two-Stage HP) NEU HOT O EMR W1 O C G R * Typical Two Stage Heat Pump heating and Auxiliary/Emergency Heating Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WIRING DIAGRAMS 8 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 2 7 GN COOL DELAY RD TERM 3 BL RD 8 GN RD BK ELEC RD 9 2 3 BK BL SEE NOTE 6 1 BK BIAS UNUSED BR 6 6 PL2 BL 5 BK 4 BIAS 7 9 8 3 ADJUST 5 LEARN - 4 RD DEHUM SEE NOTE 7 24 PL1 WH RD SEE NOTE 5 1 1 HEAT AF YL BK BK HTR1 8 L2 FL FL RD WH BK 2 YL M7 FL RD 6 R BL HTR2 NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER TL TL TWO (2) ELEMENT ROWS 8 L1 BK M4 M2 HTR2 R2 9 L2 RD M1 3 BK 1 BK M1 BK BL ONE (1) ELEMENT ROWS TL HT R3 TL M2 M3 YL HT R2 RD FL BL L1 TL L1 4 R2 HTR3 9 RD 8 RD M4 R1 BK M3 9 WH BK BL M3 6 BK RD BK PU RD 6 4 BK KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN T...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории