Войти:
Оценок - 4, средний балл: 3.3 ( )

Инструкция по эксплуатации RedMax, модель EBZ8050RH

Производитель: RedMax
Размер: 1.77 mb
Название файла: 58187b4d-f34f-407d-8280-f332e35ec5e3.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


Frame 2. Shoulder Strap 3. Spark Plug Cap 4. Throttle Lever 5. Stop Switch (behind) 6. Net 7. Choke Lever 8. Air Cleaner 9. Volute Case 10. “CAUTION” Label 11. Elbow 12. Fuel Tank 13. Recoil Starter 14. Ignition Switch 15. Engine Cover 16. Intake Cup ¦ MODEL EBZ8050/EBZ8050RH Dimensions (L x W x H) mm (in) EBZ8050·······································································································390x540x496 (15.4x21.3x19.5) EBZ8050RH ·································································································390x490x496 (15.4x19.3x19.5) Dry Weight kg (lbs)····································································································································11.5 (25.4) Fuel Tank Capacity liter (fl. oz)····················································································································2.3 (77.7) Engine Type ··········································································································Air cooled 2-cycle gasoline engine Piston Displacement cm3 (cu. in) ···············································································································71.9 (4.39) Air Filter ·······················································································································2-stage fresh flow filter system Carburetor (Diaphragm) valve type··················································································································Rotary Ignition System······································································································································Digital ignition Spark Plug························································································································NGK CMR7H (Noise-proof) Muffler ·································································································································Spark arrester equipped Operating Engine Speed rpm ················································································································2000 to 6700 Fuel Consumption liter/h (fl. oz/h) ···············································································································1.9 (64.3) Average Air Volume (w/std Pipe) cu. m/min (cfm)······················································································19.4 (685) Max. Air Volume (w/o Pipe) cu. m/min (cfm) ······························································································25.9 (915) Max. Air Velocity m/sec (mph)·······················································································································90 (201) Emission Compliance Period hrs.·························································································································300 Noise Level (50 Feet ANSI B175. 2-2000) dB(A) ····································································································77 Specifications are subject to change without notice. 2. Specifications (6) ¦ EMISSION CONTROL An emission control label is located on the machine. US-5 EBZ8050/RH U S • The blower is used for blowing away leaves and other debris on the ground. When operating the blower, the operater must stand with both feet firmly on the ground. Do not operate the blower while standing on a ladder or a stand. • Under no circumstances may the design of the machine be modified without the permission of the manufacturer. Always use genuine accessories and parts. Non-authorized modifications and/or accessories or parts can result in serious personal injury or the death of the operator or others. • When planning your work schedule, allow plenty of time to rest. Limit the amount of time over which the product is to be used continuously to somewhere around 30 ~ 40 minutes per session. Also try to keep the total amount of work performed in a single day under 2 hours or less. ¦ Basic safety rules 1. Never operate a blower when you are fatigued, ill, or upset, or under the influence of madication that may make you drowsy, or if you are under the influence of alcohol or drugs. 2. Wear the following protective equipments when operating the blower. a: Approved ear protection to reduce the risk of hearing loss. b: Approved (ANSI Z87.1.) eye protection and foot protection to reduce the risk of injury associated with thrown objects. c: Face filter mask in dusty conditions to reduce the risk of injury associated with the inhalation of dust. d: Wear sturdy rubber-soled shoes or shoes with some other form of anti-slip protection to help protect you against falling. e: Wear thick anti-vibration gloves to reduce the risk of whitefinger disease. f: Do not wear loose clothing, scarves, neck chains, unconfineed long hair, and like to reduce the risk of injury associated with objects being drawn into air intake and rotating parts....

Эта инструкция также подходит к моделям:
Системы вентиляции - EBZ8050 (1.77 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории