Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Bryant, модель CM5A

Производитель: Bryant
Размер: 121.7 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Direct interpolation is permissible. Do not extrapolate. CFM — Cubic Ft per Minute 4. SHC is based on 80° F db temperature of air entering coil. EWB — Entering Wet Bulb (° F) Below 80° F db, subtract (Correction Factor x CFM) SHG — Gross Sensible Capacity 1000 Btuh from SHC. Above 80° F db, add (Correction Factor x CFM) to SHC TCG — Gross Cooling Capacity 1000 Btuh 5. All data points are based on 10° F superheat leaving coil. SHC CORRECTION FACTOR NOTES: 1. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: sensible heat cap. Leaving db = entering db — 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (hlwb) Interpolation is permissible. total capacity (Btuh) Correction Factor = 1.09 x (1 – BF) x (db – 80) hlwb = hewb — 4.5 x CFM where hewb = enthalpy of air entering coil. BYPASS ENTERING AIR DRY-BULB TEMPERATURE (° F) 79 78 77 76 75 Under 75 FACTOR 81 82 83 84 85 Over 85 Correction Factor 0.10 0.20 0.30 0.98 0.87 0.76 1.96 1.74 1.53 2.94 2.62 2.29 3.92 3.49 3.05 4.91 4.36 3.82 Use formula shown below. —5— COIL STATIC PRESSURE DROP (IN. WC) UNIT SIZE BULB AIR QUANTITY (CFM) 024 WET DRY 600 700 800 900 1000 0.11 0.09 0.14 0.12 0.19 0.15 0.23 0.19 0.27 0.22 036 WET DRY 1000 1100 1200 1300 1400 0.22 0.19 0.28 0.23 0.32 0.27 0.37 0.31 0.42 0.36 042 WET DRY 1100 1200 1300 1400 1500 0.24 0.20 0.28 0.24 0.32 0.29 0.38 0.33 0.43 0.39 048 WET DRY 1200 1300 1400 1500 1600 0.30 0.27 0.35 0.29 0.40 0.33 0.45 0.38 0.51 0.43 —6— ACCESSORY USAGE ACCESSORY KIT NO. USED WITH Evcon/Coleman/AirPro Nordyne/Miller/Intertherm Gas Furnaces Electric Furnaces Gas Furnaces Electric Furnaces DGRT—A 7900 DGRT—B DGAT 3400 3400A 3500A8— EB—B MGHA MGBA MGBB MGHB E1EB E1EH FEBA FEBB FEH2 FEHB BLOWER PACKAGES KMABA01013TG X* X† — — X — — X† — — — — KMABA02014TG X* X‡ — — X X‡ X‡ X‡ — — — — KMABA03013TE — — — — — — — — — X** — — KMABA04014TE — — — — — — — — — X** — — KMABA05013TE — — X** — — — — — — — X** X** KMABA06014TE — — X** — — — — — — — X** X** CONTROL BOXES KMACC02014WG X — — — X X — — — — — — KMACC0401E14 — — — — — — — — — X†† — — KMACC0601FE4 — — — — — — — — — — X†† X†† FILTER KIT KMAFK0101NFK — — — — — — — — X X X X INSULATION KITS KMAIK0101E1I — — — — — — — — X X — — COIL SHELF KIT KMACR0101CRI — — X X — — — — — — — — * Requires additional control box kit. † Only required on high static 3-ton applications. ‡ Only required on 3-1/2-ton and 4-ton applications. ** Blower package comes with necessary control box. Additional control box kit not required. †† Only required if using existing furnace blower. X—Indicates recommended use of product. —7— SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: • Unit Familiarization • Maintenance • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG 1-800-962-9212 [ ] Packaged Service Training [ ] Classroom Service Training A94328 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS CM5A.24.1 © 1997 Bryant Heating and Cooling Systems, 7310 W. Morris St., Indianapolis, IN 46231 —8— PRINTED IN U.S.A. Catalog No. 12CM-5A1 5-97 ...

Эта инструкция также подходит к моделям:
Системы вентиляции - CM5B (121.7 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории