Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Black & Decker, модель BL1500

Производитель: Black & Decker
Размер: 3.8 mb
Название файла:
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


This equipment must be used with a suitable polarized 2 wire or 3 wire extension cord. Polarized connections will fit together only one way. Make sure that the receptacle end of the extension cord has large and small blade slot widths. If the plug does not fit fully into the extension cord, reverse the plug. If it still does not fit, obtain a suitable extension cord. If the extension cord does not fit fully into the outlet, contact a qualified electrician to install the proper outlet. Do not change the tool plug or extension cord in any way. Minimum Gage for Cord Sets Volts Total Length of Cord in Feet 120V 0-25 26-50 51-100 101-150 (0-7,6m) (7,6-15,2m) (15,2-30,4m) (30,4-45,7m) 240V 0-50 51-100 101-200 201-300 (0-15,2m) (15,2-30,4m) (30,4-60,9m) (60,9-91,4m) Ampere Rating More Not more American Wire Gage Than Than 0 - 6 18 16 16 14 6 - 10 18 16 14 12 10 - 12 16 16 14 12 12 - 16 14 12 Not Recommended FUNCTIONAL DESCRIPTION a. Power head b. Upper blow tube c. Lower blow tube d. Leaf Blaster Attachment e. Concentrator f. Upper vac tube g. Lower vac tube h. Shoulder bag a b c d e f g h 3 ASSEMBLY FOR BLOW MODE WARNING: Before attempting any of the assembly steps below, ensure product is switched off and disconnected from the power supply. BLOW TUBE ASSEMBLY (FIGURES 1-4) • Ensure grill cover is attached to the power head. If not, attach cover as shown in the inset of figure 1. NOTE: Unit will not operate in blow mode without grill cover in place. Align the upper and lower tubes as shown in figure 1. • Push the lower tube firmly into the upper tube, until the tubes click into place. • Blow tubes must be assembled to the power head before use. • Never operate without both lower and upper tubes assembled. • In the interest of safety, it is not intended for the tubes to be separated once assembled. • Push the tube assembly onto the power head until it is in the fully locked position (figure 2). • Use the air concentrator attachment to target air flow to a tighter area. Add the attachment to the assembly as shown in figure 3. Push on until hole in tab engages raised post on tube. • Use the leaf blaster attachment to rapidly move air back and forth to remove stubborn debris from grassy areas. Add the tube to the assembly as shown in figure 4. Push on until hole in tab engages raised post on tube. To lock the leaf blaster attachment and reduce the back and forth motion, push forward on the locking tab. ASSEMBLY FOR VACUUM MODE SHOULDER COLLECTION BAG (FIGURE 5) • Attach the shoulder collection bag to the power head as shown in figure 5. VACUUM TUBE ASSEMBLY (FIGURES 6, 7, 8) • Vacuum tubes must be assembled together before use. • Align the notches and the triangles on upper and lower tubes. (figure 6) • Push the lower tube firmly into the upper tube, until the triangles click into place. (Never operate apart). • In the interest of safety, it is not intended for the tubes to be separated once assembled. 3 2 1 4 5 6 4 • Remove the fan cover from the bottom of the power head by pressing the spring loaded release button (located on the back of the power head) and pulling the cover off (figure 7). • Attach the vacuum tube assembly to the power head (figure 8) by locating the assembly as indicated by arrow, then pivot about this point until the locking/release catch is fully engaged. REMOVING BLOW TUBE, VAC TUBE OR COLLECTION BAG (FIGURE 7 & 9) • To remove the blow tube, vac tube or shoulder collection bag, depress the release button on the power head and pull straight off (figure 7 & 9). OPERATION USE AS A BLOWER: ALWAYS WEAR SAFETY GLASSES. WEAR A FILTER MASK IF THE OPERATION IS DUSTY. USE OF RUBBER GLOVES AND SUBSTANTIAL FOOTWEAR IS RECOMMENDED WHEN WORKING OUTDOORS. FOR HOUSEHOLD USE ONLY. WARNING: CUT HAZARD. When turning the tool off for tube installation or any other reason, wait 10 seconds for the fan to stop rotating before disassembly. • Do not use in vacuum mode without the vacuum tubes and collection bag in place. • Always switch off and remove the plug from the electrical supply when: • Changing from blower to vacuum. • The power supply cord has become damaged or entangled. • You leave blower/vac unattended. • Clearing a blockage. • Checking, adjusting, cleaning or working on blower/vac. • Use blower/vac only in daylight or good artificial light. ON/OFF SWITCH (FIGURE 10) MODEL LH5000 Your blower vac is fitted with a variable speed switch located on the top of the power head below the handle. • To turn the tool ON, rotate the knob clockwise. The further the knob is rotated, the higher the air speed. • To turn tool OFF, rotate the knob counterclockwise to the off position (0). MODEL LH4500 Your blower vac is fitted with a two speed switch located on the top of the power head below the handle. • To use in low speed, rotate the knob clockwise to Position I. To use in high speed, rotate the knob clockwise to Position II. • To turn tool OFF, rotate the knob counterclockwise to the off position (0). 9 8 7 10 5 MODEL...

Эта инструкция также подходит к моделям:
Системы вентиляции - 90538065 (3.8 mb)
Системы вентиляции - LH5000 (3.8 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории