Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Delhi Industries, модель DSQ-D-10

Производитель: Delhi Industries
Размер: 46.7 kb
Название файла: DirectDrive_SquareInline_OIPM.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Where these components are not protected by ductwork, cabinets or covers, appropriate guards should be employed to restrict exposure to rotating parts. Access doors should not be opened with the fan operating to avoid foreign objects being drawn into the system. On initial start-up a careful inspection should be carried out to ensure no foreign material is present which could become airborne in the system. Read installation and operation instructions carefully before attempting to install, operate or service Delhi DSQ-D Series Blowers. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference. Suspension Mount Install 4 supplied angle iron mounting brackets on upper cabinet front & rear or sides (illustrated) Customer supplied suspension rods (4) Model Motor Weight (lbs.) DSQ-D-10 1/4 HP 120V 60 Hz 55 DSQ-D-12 1/2 HP 120V 60 Hz 77 DSQ-D-13 3/4 HP 120V 60 Hz 86 DSQ-D-15 1-1/2 HP 120V 60 Hz 115 W ¡Li Fig. 1 Base Mount • 4 angle iron mounting brackets are supplied on the cabinet bottom (illustrated). Inspect unit for damage, report any shipping damage to carrier. Check all fasteners, re-tighten as required. Rotate the blower wheel by hand to ensure free rotation. If rubbing occurs, loosen the inlet venturi bolts, re-position the venturi to establish clearance, re-tighten bolts. Installation (Fig. 1) The 4 angle brackets provided allow for base or suspension mounting. Suspension Mounting For suspension mounting, move the 4 angle iron mounting brackets to the four upper corners (front & rear or both sides) using the hardware provided, secure the unit to 4 customer provided suspension rods. Base Mounting For base mounting, 4 angle iron mounting brackets are supplied in the four lower corners (front & rear or both sides) secure these to the customer supplied base. Vibration isolation (not included). Recommended (spring or rubber) for both suspension or base mount. Electrical Warning: Ensure power supply is disconnected & locked out prior to making electrical connections. Before connecting the motor to the electrical supply, check the electrical characteristics and wiring instructions as indicated on the motor nameplate or as shown below. Complete electrical connections as indicated. Warning: A ground wire must be connected from the motor housing to a suitable electrical ground. Motor Wiring Diagram DSQ-D-10, 12 & 13 MOTOR WIRING - SINGLE SPEED '■VHITE t L HE 1 SLACK gREEN _|||. GROUND TO 1 JUNCTiOH BOX DSQ-D-15 MOTOR WIRING - TWO SPEED VHJLÛW . LOW. OP i" lime : GRDUNDTO JUHCTIOH BOX Speed Control Wiring Diagram For DSQ-D10, 12 & 13 Single Speed Motors Only a swrcn K TPiAC AC LINE CONNECTIION DIAGRAM FOR 2 WIRE CONTROL WARNING: Power must be turned off before wiring. Connect control in series with motor and line voltage - never connect control across line. Minimum speed adjustment - factory set. See installation instructio...

Эта инструкция также подходит к моделям:
Системы вентиляции - DSQ-D-12 (46.7 kb)
Системы вентиляции - DSQ-D-13 (46.7 kb)
Системы вентиляции - DSQ-D-15 (46.7 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории