Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Technics, модель SX-KN6500

Производитель: Technics
Размер: 5.83 mb
Название файла: SXKN6500.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Press the YES button to execute the function, or press the NO button to cancel the function. • Note that if the END command is included in the source data, it is also copied. Any data following the END command is not copied. 98 QQTG0618 Part IV Sequencer MEASURE ERASE Erase the recorded contents of specific measures. You can also specify which type of data is to be erased. • Note that only the contents of the measures are erased, not the measures themselves; the length of the performance remains the same. MEASURE DELETE 1. Use the TRACK a and v buttons to specify the track number. • This function does not work for the RHYTHM part or CHORD part in which a repeat command has been stored. • If ALL is selected, data is erased from the specified measures of ail the tracks at one time. 2. Use the FIRST MEASURE a and v buttons to specify the start point {measure number). 3. Use the LAST MEASURE a and v buttons to specify the end point (measure number). 4. Use the ERASE DATA a and v buttons to specify the type of data to be erased. ALL: All data is erased. NOTE: Only note data is erased. CONTROL: Only control data (volume, effect and other panel settings as well as selection changes) is erased. Delete specified measures from a track. • The length of the performance accordingly decreases by the number of deleted measures. DELETERS .«t. ¿»¿v fc. iwSsissibw TRACK FIRST LAST . ■ïî,î«r.«. .v .. J' i ixi&id MEASURE MEASURE ms 1 1 urm 1. Use the TRACK a and v buttons to select the track from which measures are to be deleted. • This function does not work for the CHORD or RHYTHM track in which the repeat function has been stored. • If ALL is selected, the specified measures are deleted from all the tracks at one time. 2. Use the FIRST MEASURE a and v buttons, to specify the first measure to delete. 3. Use the LAST MEASURE a and v buttons to specify the last measure to delete. 4. Press the OK button. • The confirmation display appears. Press the YES button to execute the function, or press the NO button to cancel the function. 5. Press the OK button. • The confirmation display appears. Press the YES button to execute the function, or press the NO button to cancel the function. 99 QQTG0618 Sequencer Sequencer Part IV Sequencer MEASURE INSERT Insert specified measures at a specified point. • The length of the performance accordingly increases by the number of inserted measures. 1. Specify the measures you wish to copy from the source track. • On the FROM side, specify the settings with the corresponding buttons. TRACK: Specify the track number you wish to copy the measures from. • This function does not work for the CHORD or RHYTHM track in which the repeat function has been stored. • If ALL is selected, the measures are inserted in all tracks at the same time. FIRST MEASURE: Specify the first measure to copy. LAST MEASURE: Specify the last measure to copy. 2. Specify where you wish to insert the selected measures. • On the TO side, specify the settings with the corresponding buttons. TRACK: Specify the track number. • Measures from the CHORD, RHYTHM or CONTROL track can only be inserted in the same track. START MEASURE: Specify the start point to insert the selected measures. REPEAT: Specify the number of times the selected measures are to be repeated. 3. Press the OK button. • The confirmation display appears. Press the YES button to execute the function, or press the NO button to cancel the function. • Note that if the END command is included in the source data, it is also inserted. Any data following the END command is not inserted. APC TO SMF CONVERT This function converts data to Standard MIDI File (SMF) format, allowing you to play back song data created using this instrument’s automatic accompaniment and/or PERFORMANCE PADS on an external sequencer or sound generator. llii&fr —.......•••..... PART j ORTA flPC'PRD j TR 2 R1GHT2 I ’ OFF I TR 3 LEFT OFF | ÎR 4 PART 4 OFF j TR S CHORD » — j TR 6 CONTROL TR 7 RfffTHft - — j TR 8 DRtinS v OFF ! ^_ 1.Use the TR ▲ and ▼ buttons to select the track you wish to convert. • In the PART column, the part name currently assigned is shown. • In the DATA column, a check mark (V) indicates a track in which data is stored. • Tracks in which RHYTHM, CONTROL, APC and CHORD parts are stored cannot be selected {---is shown). 2. Use the APC/PAD a and v buttons to select the parts you wish to convert. • Parts that are set to OFF will not be converted. 3. Press the CONVERT button. • Note that after the conversion, the APC/CHORD part data is cleared; if necessary, save this data beforehand. • A confirmation display appears. Press EXECUTE to continue with the conversion, or press the CANCEL button is you wish to discontinue. • After the EXECUTE button is pressed, the conversion begins. Conversion takes the same length of time as playback. • If you wish to discontinue the conversion process midway, press...

Эта инструкция также подходит к моделям:
Синтезаторы/фортепиано - SXKN6500 (5.83 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории