Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации HP, модель HP SAS Host Bus Adapters

Производитель: HP
Размер: 331.55 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


0xe0000000017716b0 DoCalllist+0x3a0
End of Stack Trace
This problem happens on HP Integrity rx2600, rx3600, rx6600, BL860c systems, and on rx7640
and rx8640 systems with AH303A adapters installed.
Corrective Action: Reboot the system to recover from the panic.
5 Recommendations
This section provides recommendations for highest performance and reliability.

Updating Physical Disk Firmware
Consider the following when you use sasmgr(1M) to update the firmware of physical disks
that are part of a RAID volume attached to an HP 8 Internal Port SAS Controller:
— If you are updating the firmware on two or more disks that are part of a RAID volume,
do not issue multiple commands to download simultaneously.
— If the disk firmware download to a disk that is part of a RAID volume fails or is
terminated, reset the controller using the sasmgr(1M) reset command:
sasmgr -f reset -D /dev/sasdX
(Replace X with the instance of the SAS controller.)

Swapping Spare Disks
Consider the following when you swap physical disks in a RAID volume controlled by an
HP 8 Internal Port SAS Controller:
— Before swapping a spare disk, delete it using sasmgr(1M):
sasmgr delete -D /dev/sasdX -q raid -q spare
(Replace X with the instance of the SAS controller.)
After the new disk is installed, use sasmgr(1M) to configure the new disk as spare:
sasmgr add -D /dev/sasdX -q raid -q spare -q enc_bay=:
(Replace X with the instance of the SAS controller and : with the location
of the disk to be configured as spare.)
— By default, RAID volumes are created with Auto-Configure enabled. If you swap a
physical disk that is part of a RAID volume, a resync begins and data on the new disk
is lost. Do not insert a replacement disk unless you are sure that existing data is backed
up.
6 Compatibility and Installation Requirements
This section describes the compatibility information and installation requirements for this release.
For specific installation instructions, see the HP 8 Internal Port SAS Controller and HP Multi-Port
Internal SAS Controller Support Guide
or the AH303A PCIe SC44Ge SAS Host Bus Adapter for Integrity
Servers Support Guide
, at:
http://docs.hp.com/en/netcom.html
6.1 Required Software
The SerialSCSI-00 bundle depends on SAS-COMMON, which is delivered as a part of the
CommonIO bundle. Before installing SerialSCSI-00, be sure that SAS-COMMON is installed.
This version of SerialSCSI-00 requires version C.7.4.157 or later of Ignite-UX.
You can download these products from the Software Depot website:
http://www.hp.com/go/softwaredepot
Search for CommonIO and Ignite-UX.
6


...

Эта инструкция также подходит к моделям:
Сетевое оборудование - HP-UX 11i v3 I/O Cards (331.55 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории