HP X.25 Release Notes
Patches and Fixes in This Version
Table 1-5
Fixes (Continued)
SR Number
Description
8606231715
The level 2 state toggles between up and down and a lot of CRC errors,
bad frames and other issues are reported in statistics. This problem has
been found while the X.25 J3526A card was connected to a Cisco router
using V.35.
8606228517
When the HP-PB PSI card reports numerous "receive aborts", using
"x25stat" command many times can lead to a system panic. The
following message was seen while using "dmesg": "X.25 problem: No
more timeout data structure".
8606196727
The X.25 level 2 sends an unexpected FRMR frame and does not stay
up. This problem has been observed with a NORTEL DPN100 switch.
However, it may also happen with other configurations.
8606266719
System panics when the X25 package is stopped and a LAN is
unplugged, thus stopping a package.
8606268596
While disabling "x29printd / x29server / x29uucpd" daemons through
SAM the x25 configuration was not updated.
8606182798
System panics when following sequence of actions are performed, First,
start the application which attaches to a PVC for data transfer. Second,
application is terminated/killed. Third, another application is started
which attaches to the same PVC and last, the interface cable for the
port is disconnected.
8606183710
System panics in X.25 socket code when X.25 facilities are used.
8606183954
System panics as the putq routine and getq routine enter a race
condition. This is because the putq routine does not synchronize the
calls into streams module.
8606185082
x25init returns an error on J3526A card with the message "Link of
wan0012 under lapb0012 failed"
8606200067
x25stop/x25init hangs on a J3526A card after doing 'ricreset'.
8606201005
set_timer() may not restart the timer sometimes. This may lead to
LAPB not doing timer recovery operations at times.
8606203532
System panics due to spin lock deadlock in the function
J3526_F_time_is_out().
16