Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Honda Power Equipment, модель Submersible Pump WSP53AA

Производитель: Honda Power Equipment
Размер: 1.31 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Do not use an extension cord with the pump. • Do not cut off the ground pin or use an adapter fitting. • Do not work on the pump or switch until any or all power cords are unplugged. IMPORTANT INSTRUCTIONS BEFORE INSTALLATION Failure to follow these instructions may cause serious bodily injury and/or property damage. 1. Before installing or servicing your pump, BE CERTAIN the pump power source is disconnected. 2. Installation and electrical wiring must adhere to state and local codes and must be complete before priming the pump. Check appropriate community agencies or contact local electrical and pump professionals. 3. CALL AN ELECTRICIAN WHEN IN DOUBT. Pump should be connected to a separate 15 amp GFCI circuit breaker or 15 amp fuse block and a GFCI receptacle. Plugging into existing outlets may cause low voltage at the motor, resulting in blown fuses, tripping of the motor overload, or a burned-out motor. 4. Do not connect the pump to a power supply until permanently grounded. For maximum safety, ground the pump to a circuit equipped with a fault-interrupter device. 5. The voltage of the power supply must match the voltage of the pump. 6. Before installing the pump, clear the sump basin of any water, debris, or sediment. WARNING: The sump basin must be vented in accordance with local plumbing codes. Honda WSP pumps are not designed for and CANNOT be installed in locations classified as hazardous in the National Electric Code, ANSI/NFPA 70. 7. The sump basin should be between 18" and 24" in diameter and made of plastic, fiberglass, or concrete. 8. The following may cause severe damage to the pump and will void warranty: • Using an extension cord • Cutting off the ground pin or using an adapted fitting • Working on the pump or switch while plugged in • Removing the motor housing, unscrewing the impeller, or otherwise removing the impeller seal Piping Plastic PVC pipe is shown in the illustrations, but galvanized steel or copper pipe may be used if desired. All piping must be clean and free of all foreign matter to prevent clogging. Use thread compound on all threaded joints unless specified otherwise. Submersible Pump Installation Submersible Pump Installation pump fails to operate properly after installation, refer to “Troubleshooting Checklist” on page 14 or contact a Honda servicing dealer. General Materials Needed • One can of PVC cement (read the instructions carefully) • One can of thread compound (read the instructions carefully) • One male PVC adapter (1-1/4" for 1/3 HP, 1-1/2" for 1/2 and 3/4 horsepower models) • Enough rigid PVC pipe and couplings to reach from the bottom of the sump basin to the discharge (1-1/4" for 1/3 HP, 1-1/2" for 1/2 and 3/4 horsepower models) • One Check Valve. Tools Needed For All Pump Installations Pipe wrench, Slot screwdriver, 24-tooth hacksaw, knife or round file. Step 1. Apply thread sealant and thread a male PVC adaptor into the pump discharge opening. Step 2. Cement a 15" piece of PVC pipe to the adaptor. Use appropriate diameter piping. Drill a 1/8" relief hole in the pipe 5" above the pump connection. This hole prevents the pump from air-locking. Step 3. Clamp the Check Valve to the top of the 15" PVC pipe with the water flow arrow pointing away from pump. Step 4. Lower the pump into the basin. Clamp needed PVC discharge pipe and fittings to the open end of the Check Valve. Step 5. Plug in the pump and fill the sump basin with water. The pump should turn on when the water level reaches 13'' to 14''. If it does not turn on at the 13'' to 14'' water level, remove the float cord from the clip and re-attach it in a higher or lower position so that the pump turns on at the 13'' to 14'' water level. CLIP MOVE CORD UP OR DOWN FLOAT CORD Step 5. Plug in the pump and fill the sump basin with water. The pump should turn on when the water level reaches 13'' to 14''. If it does not turn on at the 13'' to 14'' water level, remove the float cord from the clip and re-attach it in a higher or lower position so that the pump turns on at the 13'' to 14'' water level. CLIP MOVE CORD UP OR DOWN FLOAT CORD Step 6. Perform several ON-OFF cycles to assure satisfactory operation. Performance Table (Capacity in Gallons per Minute) Pump Total Head 5 10 15 20 25 30 35 40 45 50 WSP33K1AA 40 33 25 15 WSP53AA 73 67 60 51 40 27 9 WSP73AA 74 67 58 49 39 27 16 WSP Submersible Pump Installation Diagram WSP Submersible Pump Installation Diagram 1-1/2" check valve with rubber sleeve connectors for 1-1/4" and 1-1/2" pipe *All equipment other than pump to be supplied by others. Pump only supplied by Honda. 10-1/2" Min. Bottom of inlet pipe 14" Min. Sump pump Shut-off gatevalve (optional) Sump basin 18" to 24" dia. plastic, fiberglass, or concrete Discharge piping can be PVC or ABS plastic with proper adapters, or can be galv. steel Drill 1/8"relief hole 5" above pump discharge Turn-on level Lifting handle Mechanical float switch 11" 13-3/8" Turn-off level Motor Wiring Diagram Motor Wiring Diagram O...

Эта инструкция также подходит к моделям:
Сантехника - Submersible Pump WSP33AA (1.31 mb)
Сантехника - Submersible Pump WSP73AA (1.31 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории