Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Honda Power Equipment, модель Submersible Pump WSP33AA

Производитель: Honda Power Equipment
Размер: 1.31 mb
Название файла: a7951250-d392-458c-9c33-80773040300d.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


We hope you are pleased with your purchase and that our pumps will provide you with long service life and exceptional performance. Thank you for purchasing this Honda Stainless Steel Sump Pump. We hope you are pleased with your purchase and that our pumps will provide you with long service life and exceptional performance. Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance. Please retain the following information for your records and to help expedite service: Purchase Date: ____________________________ Purchased From: ____________________________ Serial No: ____________________________ (Located on the pump nameplate) Important Safeguards Important Safeguards Read All Instructions Prior to Installation (SAVE THESE INSTRUCTIONS) Installation/Operation • Never lift or carry the pump by the electrical cord. Use a chain or rope affixed to the handle to install or remove the pump. To reduce potential damage to the pump from inadvertent lifting by the electrical cord, refer to “Proper Lifting” on page 2. • This pump must be operated fully submerged. Pump must be shutdown if the sump, pit, or pond level drops below the motor housing. • Pump is designed to pump clean water (maximum temperature of 122°F) withsuspended solids up to 3/16 of an inch. Larger solids will clog the suction strainer plate leading to dry running and subsequent failure. (Note: Pumping sand, gravel, and other hard debris will shorten the life of the pump.) Elevate the pump with bricks or other support above the sump, pit or pond bottom if debris is present. • Clean the filter basin when cleaning the inlet filter media when the pump is shut down. • If used with a float switch, the float must have a full range of motion to operate properly without obstruction. Refer to “Submersible Pump Installation” on page 9. • Pump should be mounted upright only (vertical). Never lay the pump on its side. Electrical Requirements • Pump must be operated with a GFCI breaker of at least 15 amps. • High OR Low Voltage can damage the pump. Power from your utility or generator set cannot be more or less than 10% of the rated voltage shown on the pump. • Maximum distance from power source and pump must not exceed 100 feet using 16/3 electrical cables. This distance is from the breaker box and includes the pump cord. If the run is longer, consult a qualified electrician or your dealer. • Lightning strikes can destroy the capacitor in your pump. Ensure proper protection is provided. • Consult this manual for additional operation and application information. Proper Lifting Proper Lifting Note that this will help prevent damage due to inadvertent lifting of the pump by the power cord. Rope attached to the automatic pump for lifting and installation. Rope attached to the manual pump for lifting and installation. Contents Contents General Application Information 3 Safety Information and Introduction 5 General Specifications 6 Tools Needed 6 Materials Needed 6 Installation Instructions 7 Electrical Information 8 Submersible Pump Installation 9 Performance Table (Capacity in Gallons per Minute) 10 WSP Submersible Pump Installation Diagram 11 Motor Wiring Diagram 12 Operation 12 Technical Specifications 13 Troubleshooting Checklist 14 Maintenance and Service 15 Sectional View – WSP33K1AA 16 Sectional View – WSP53AA, WSP73AA 18 Disassembly and Assembly 19 Customer Service Information 20 General Application Information The Sump and Installation If your basement does not currently have a sump installed, it will be necessary to check local plumbing codes as to the acceptable type of sump that may be used. Materials commonly specified are: clay tile, fiberglass, steel, concrete, and polyethylene. It may be necessary to cut a hole in the basement floor and excavate for the sump. Plumbing and electrical contractors can advise on proper installation of drain tiles, sump, pump, and electrical service. Honda recommends that a solid sump base be provided. The sump is fed by drain tile placed around the outside and/or inside basement walls at the footings. In applications where a gravel base must be used to relieve hydraulic pressure under the basement floor, be sure to provide a permanent and solid base for the pump (bricks or a steel plate). A sump cover capable of supporting 200 pounds should be employed to contain odors and for obvious safety reasons. Electrical Installation Electrical Installation Discharge Piping Installation To assure the maximum performance from your sump pump, the discharge pipe size and piping fittings should not be smaller than the discharge port of the pump. Smaller pipe will add to friction losses and reduce the capacity of the pump. Normally accepted materials are galvanized pipe, rigid plastic pipe, or acceptable flexible pipe or hose. A piece of flexible hose between the pump discharge and the discharge piping will provide for ease in alignment, reduce vibration and...

Эта инструкция также подходит к моделям:
Сантехника - Submersible Pump WSP53AA (1.31 mb)
Сантехника - Submersible Pump WSP73AA (1.31 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории