|
Фрагмент инструкции
FINISHED WALL 79mm(7-1/8) 13mm (1/2) 23mm (7/8) C/L OF SEAT POST HOLES 140mm (5-1/2) CTR'S. 305mm (12) C/L C/L OF SUPPLY AS REQUIRED FINISHED FLOOR 176mm (7) 736mm (29) 473mm (18-1/2) 140mm(5-1/2)203mm (8) 343mm (13-1/2) 305mm (12) 384mm (15) 767mm (30-1/4) 388mm (15-5/16) 413mm (16-1/4) 355mm (14) 6 7 INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions. 8a 8bBefore continuing, determine the type of water supply connecation you have from the chart below and use the appropriate assembly parts required to properly reconnect the water supply. DO NOT use plumber's putty to seal these fittings. CAUTION: DO NOT USE CONE WASHER WITH PLASTIC SUPPLY LINE. These parts must be used as illustrated to insure water-tight connection. Use of existing coupling nut may result in water leakage. Water supply tube or pipe must extend at least 1/2" inside threaded shank of valve (does not apply to flanged tubing). Use existing coupling nut and washer. Use existing spiral cone washer. Fluidmaster cone washer may not seal completely on spiral type supply line. Captive cone washers already included. No additional washers needed. CAUTION: Overtightening of LOCK NUT or COUPLING NUT could result in breakage and potential flooding. METAL/COPPER FLARED TUBING METAL FLANGED TUBING METAL SPIRAL TUBING VINYL/BRAIDED CONNECTOR LOCK NUTLOCK NUT LOCK NUT LOCK NUT COUPLING NUT COUPLING NUT EXISTING COUPLING NUT COUPLING NUT WATER SHUT-OFF WATER SHUT-OFF WATER SHUT-OFF WATER SHUT-OFF CONE WASHER EXISTING CONE WASHER EXISTING WASHER With correct washers in place (see Step 8a), tighten COUPLING NUT 1/4 turn beyond hand tight. DO NOT OVERTIGHTEN. ! WARNING: Do not use plumber’s putty, pipe dope, or any other sealant on the water supply connection to this tank. If the connection leaks after hand tightening, replace the supply line. If the connection continues to leak with the new supply line, replace the fill valve. Warranty is void if any type of sealant is used on the water supply connection. a. Position toilet squarely to wall and, with a rocking motion, press bowl down fully on wax ring and flange. Alternately tighten nuts until toilet is firmly seated on floor. CAUTION: DO NOT OVERTIGHTEN NUTS OR BASE MAY BE DAMAGED! b. Install bolt covers: 1. Make sure that the bolt cover area on the toilet is clean and dry (see figure). Use a dry piece of cloth or soap and water if needed. 2. Take plastic bolt cover and peel the brown protective film off on both ends. The adhesive part is now visible and ready to be placed on the toilet (see figure). 3. Gently place the bolt cover on the toilet area (see picture) and if everything is aligned, push bolt cover firmly so it remains in place. 4. If not aligned, you can still take it off and put it back so it is aligned. 5. Repeat Step 3 for second bolt cover which is to be placed on opposite side of the toilet. 6. After 24 hours, the bolt cover adhesive has completely set off and if needed, you can remove/replace as needed. The dual lock technology is now in place. c. Smooth off the bead of sealant around base. Remove excess sealant. ! INSTALL TOILET CLOSET BOLT NUT BOLT COVER BOLTS CLOSET FLANGE Peel both protective films off and stick bolt cover to toilet. Back Side Front Side 6 7 INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions. 8a 8bBefore continuing, determine the type of water supply connecation you have from the chart below and use the appropriate assembly parts required to properly reconnect the water supply. DO NOT use plumber's putty to seal these fittings. CAUTION: DO NOT USE CONE WASHER WITH PLASTIC SUPPLY LINE. These parts must be used as illustrated to insure water-tight connection. Use of existing coupling nut may result in water leakage. Water supply tube or pipe must extend at least 1/2" inside threaded shank of valve (does not apply to flanged tubing). Use existing coupling nut and washer. Use existing spiral cone washer. Fluidmaster cone washer may not seal completely on spiral type supply line. Captive cone washers already included. No additional washers needed. CAUTION: Overtightening of LOCK NUT or COUPLING NUT could result in breakage and potential flooding. METAL/COPPER FLARED TUBING METAL FLANGED TUBING METAL SPIRAL TUBING VINYL/BRAIDED CONNECTOR LOCK NUTLOCK NUT LOCK NUT LOCK NUT COUPLING NUT COUPLING NUT EXISTING COUPLING NUT COUPLING NUT WATER SHUT-OFF WATER SHUT-OFF WATER SHUT-OFF WATER SHUT-OFF CONE WASHER EXISTING CONE WASHER EXISTING WASHER With correct washers in place (see Step 8a), tighten COUPLING NUT 1/4 turn beyond hand tight. DO NOT OVERTIGHTEN. ! WARNING: Do not use plumber’s putty, pipe dope, or any other sealant on the water supply connection to this tank. If the connection leaks after hand tightening,...
Эта инструкция также подходит к моделям:Сантехника - NEW SAVONA 2097.012 (169.05 kb)
Сантехника - NEW SAVONA 2097.012 (169.05 kb)
Сантехника - NEW SAVONA 2097.012 (169.05 kb)