|
Фрагмент инструкции
Or, to restore defaults to all stations , turn the Lower Line knob to select All Stations. COPY STATION DEFAULTS TO ALL STA's (Press BUTTON) 4. Press and hold the Copy button. Release the button when Copying Done is displayed. CT- COPYING......DONE! 41 Restoring PROGRAM Default Settings A\ Important: Restoring the default Program settings erases and resets all user-defined settings for all programs as follows: 1st Start Time - 12:00am Water Window - 05:00 Water Window - 16:00 Water Day Mode - Optimized by WT 2nd Start Type - High ET Day Excusion - None 2nd Start Time - 07:00 pm 1. Turn the Function dial to the COPY position. 2. Turn the Upper Line knob to select Copy Program Defaults as shown in the following example: 3. Turn the Lower Line knob to select the program A, B, C or D) to be restored. Or, to restore defaults to all programs simultaneously, turn the Lower Line knob to select All Pgm. 4. Press and hold the Copy button. Release the button when Copying Done is displayed. 42 Restoring SETUP Default Settings A Important: Restoring the SETUP defaults erases and resets all user-defined settings as follows: Adjust Display - 224 Date - No change Time - No change Time Zone - No change Auto Daylight Savings - Yes Active Stations - No Change Stack or Overlap - Stack Master Valve - Normally Closed Pump Start - Pump On Run Time Valve Test - No Max. Backup ET - 2.00 Flow Meter Mode - Off Turn the Function dial to the COPYposition. 2. Turn the Upper Line knob to select Copy Setup Defaults. COPY SETUP DEFF ULTS V _J 3. Press and hold the Copy button. Release the button when Copying Done is displayed. COPYING......DONE! 1 _) Copy Station Mode If the controller is initially programmed in the field using the Auto Station mode, but is left running in the User No ET mode, e.g., for landscape establishment, the Auto Station settings are stored in the controller memory. The Copy Station feature allows stations in User No ET mode to be quickly copied to the Auto Station mode. 43 Using the % Adjust Function The % Adjust function allows you to make minor changes in overall station irrigation rate by increasing or decreasing the watering program values proportionally by percentage. Adjustments can be made in 5% increments by Water Amount (station run time and cycles per day), and by Day Frequency/Maximum Allowable Depletion (MAD). Note: Both adjustment methods can be applied to each active station, however, DF/MAD is only available to stations operating in the Automated by WeatherTRAK mode. A\ Important: A small percentage adjustment can result in a significant change in irrigation rate. Always adjust in 5 or 10% increments, then monitor the condition of the landscape for 7 to 10 days prior to making additional adjustments. 1. Turn the Function dial to % ADJUST. The Water Amount adjustment option is selected by default. r :: N MUJUsi Water Amount 2. To adjust by Water Amount factors, continue below. To adjust by Day Frequency/MAD, continue on page 43. % Adjust by Water Amount 1. Turn the Upper Line knob to select the station number. ADJ WATER AMOUNT STA 01 A 0% = No Change V y 2. The unadjusted water amount value is 0%. Turn the Lower Line knob right to increase, or left to decrease the value in 5% increments. Maximum adjustment range is +25 to -50%. 44 % Adjust by Day Frequency/Maximum Allowable Depletion Stations assigned to the Automated by WeatherTRAK station mode can be % adjusted by watering Day Frequency/Maximum Allowable Depletion. For example, when establishing new turf, total water application can be increased while decreasing the possibility of runoff. Day Frequency is adjustable from -30% to +30% in 5% increments. The equivalent MAD value will be displayed ranging from 20% to 80% (with 50% being the standard depletion rate). 1. Turn the Lower Line knob to select Day Frequency/Depletion adjustment option. r 2. Turn the Upper Line knob to select the station number. Note: If the selected station number is assigned to a User-defined station mode, the following display will be shown: 3. Turn the Lower Line knob right to increase or left to decrease the percent value. Maximum adjustment range is +30% to -30%. Note: In the following example, the watering day frequency for station 1 has been increased by 5%, which decreased the MAD value to 45%. This change translates to irrigation being permitted when soil moisture content drops to 45% instead of the standard 50% MAD value. DAYS (MAD) STA 01 More Often (45%) 45 Using the Alerts Function If a problem, confilict or error occurs with one of the essential Intelli-Sense functions, an Alert prompt will be immediately posted. Selecting Alerts function provides a quick overview of the monitored functions, and flags the source of the alert condition. 1. Turn the Function dial to the ALERT position. FL VL CM WD DY HW SB V_y From the initial Alert display screen, the specific function causing the alert conditio...
Эта инструкция также подходит к моделям:Садовые инструменты - 12 (2.15 mb)
Садовые инструменты - 24 (2.15 mb)
Садовые инструменты - 48 (2.15 mb)