Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Dirt Devil, модель CV2200

Производитель: Dirt Devil
Размер: 753.4 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


IMPORTANT WARRANTY INFORMATION Proof of Purchase or Registration of the Dirt Devil® System is required before any warranty work will be performed by an Authorized Dealer. Registration ensures a fast and easy resolution to your warranty requirements. To register, simply call the 24-hour registration line at 1-800-822-9277, register online (or complete and return the blue warranty postcard located with this manual. IMPORTANT WARRANTY INFORMATION Proof of Purchase or Registration of the Dirt Devil® System is required before any warranty work will be performed by an Authorized Dealer. Registration ensures a fast and easy resolution to your warranty requirements. To register, simply call the 24-hour registration line at 1-800-822-9277, register online (or complete and return the blue warranty postcard located with this manual. 512 West Gorgas Street • P.O. Box 3912 Louisville, OH 44641-3912 1-800-822-8356 Dirt Devil® Built - In Central Vacuum Systems OPERATING INSTRUCTIONS General Information Do Not Store Objects on top of the power unit. This will block the motor cooling ventilation. Restricting the cooling airflow may shorten the motor life. The central vacuum is designed to vacuum ordinary household dirt and dust. The system is designed for dry pickup. A Wetvac accessory is needed if the system will be used for liquid pickup. The central vacuum system is a network of inlet valves, 2” PVC tubing, and low voltage wiring installed in the walls of your home. To operate the system, simply plug the hose into an inlet valve, attach the cleaning tool to the curved hose end and begin vacuuming. The dirt is transported through the in-wall tube system back to the dirt canister (located on the power unit). Caution: Do not allow the motor to remain turned on, unless a hose is connected or an inlet valve is open. If air is not permitted to pass through the fan blades, damage may occur to the motor. Operating Instructions Using the Central Vacuum System is easy. Simply raise the inlet valve lid, insert the hose end and attach the desired cleaning tool to the hose wand. The Power Unit is activated when the hose is inserted into the valve. Emptying the Dirt Canister & Replacing The Filter Cartridge The dirt canister – where the vacuumed dirt is deposited – is the removable lower portion of the power unit. The canister needs to be removed and emptied when it is 1/2 - 2/3 full. The filter cartridge should be replaced once a year. When the dirt canister is removed the Cyclonic Cone will be visible. The cone is designed to stay attached to the body of the power unit when the dirt canister is removed. The cone is removable to allow access to the replaceable pleated filter. To replace the cone, follow the steps listed under replacing the filter. Dirt Devil® Filtered Cyclonic MODELS: CV1800, CV2200 ILLUS. #1 Follow these steps to empty the dirt canister (refer to Illustration #1) Make sure the Power Unit is OFF. 1) Disengage the canister latches located on opposite sides of the power unit. 2) Remove the dirt canister. 3) Dispose of canister contents in trash receptacle. 4) Raise the empty dirt canister to the proper location under the power unit and engage the latches. 5) Be certain the dirt canister and the cyclonic cone seal are “seated” properly to the body of the unit. Follow these steps to replace the filter cartridge (refer to Illustration #2) Make sure the Power Unit is OFF. 1) Unlatch and remove the Dirt Canister. 2) Remove the cyclonic cone by pulling down on it. Place cone in dirt canister. 3) Remove the pleated filter by turning the filter latch 90° (counterclockwise) to disengage the filter. (The filter latch is located at the bottom of the pleated filter) 4) Insert new pleated filter (p/n 8106-01) and engage filter latch (by rotating it 90° clockwise until you feel it snap in place). 5) Raise the dirt canister (with cone inside) to the proper location under the power unit and engage the latches. 6) Be certain the dirt canister and cyclonic cone seal are “seated” properly to the body of the unit. Filter Cartridge Filter Latch (turn 90° to disengage filter) Dirt Canister Cyclonic Cone Seal Cyclonic Cone ILLUS. #2 & CV2600 General Power Unit Maintenance The simple care and maintenance instructions included here will help ensure trouble-free use of the central vacuum system. • Do not place objects on top of the power unit. The motor could overheat. • Do not allow the motor to remain “on” unless a hose is connected or an inlet valve is open. If airflow is not permitted to flow through fan blades, motor damage may occur. • Do not operate without a filter in place. • Empty the dirt canister when it is 1/2 - 2/3 full. • Change the filter cartridge once a year. • The power unit does not require any lubrication. • The exterior of the power unit can be wiped with a clean, dry cloth. Do not use liquid cleaners or water as an electrical shock may occur. • For additional service con...

Эта инструкция также подходит к моделям:
Пылесосы - CV1800 (753.4 kb)
Пылесосы - CV2600 (753.4 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории