These release notes describe the modifications and known issues for Patch 18 (P18). The application
of this patch is intended for HP 3PAR InForm OS 2.3.1.298 (MU3).
1.1 Supported Platforms
The HP 3PAR Configuration Matrix for InForm OS 2.3.1 contains information about supported hardware
and software platforms. To obtain a copy of this documentation, go to the Single Point of Connectivity
Knowledge for HP Storage Products (SPOCK) Web site at http://spock.corp.hp.com/index.aspx.
1.2 Verifying the Patch Installation
The installation of Patch 18 can be verified from an Interactive CLI session through the SPMAINT main
menu. Issue the CLI command showversion -a -b to see Patch 18 listed.
cli% showversion -a -b
Release version 2.3.1.298 (MU3)
Patches: P18
Component Name Version
CLI Server 2.3.1.298 (MU3)
CLI Client 2.3.1.298 (MU3)
System Manager 2.3.1.298 (MU3)
...
1.3 Components
Component
Version
OS
2.3.1.298 (MU3)
:
Applying this patch to the InForm OS may cause a restart of the affected OS components. With these
restarts, expected behaviors such as events and alerts may generate. The system will continue to serve
data but existing CLI or IMC sessions may be interrupted.
1.4 Modifications to the InForm OS
The following items have been addressed in this release.
Bug ID
Component
Version
59488
Update ViperC firmware to
If an online firmware upgrade is performed, the recommended defect settings
3P02 and VXC2 so SMART is to the mode page 1C will be lost. To reinstate the settings, activate the
enabled by default
disk-ready process by issuing admitpd again after dismisspd
first or servicemag start -log -pdid and then
servicemag resume.
61808
Cage failed and became
Corrects an error in serial port where characters were looped back to the
inaccessible after reset.
serial port which sometimes could cause timeout results a cage resets and
becomes inaccessible.
The fix also contains additional checks to prevent cage from being
inaccessible.