Фрагмент инструкции
Lamp Replacement
2Remove the Front cover. Place your
After lamp replacement,
fi ngertips under the Front cover and
4Loosen the lamp unit screw with a
screwdriver. Then, grasp the lamp unit
pull it from the projection display.
CAUTION:
as shown in the diagram, and slowly
follow the procedure below
Because of the possibility of injury, strictly follow the
remove from the projection display.
• Do not drop, as the impact of dropping may cause
replacement procedure below.
Warning:
the lamp to explode.
Perform lamp time reset only when the lamp has
■ Lamp replacement procedure
been replaced.
1
Lamp unit screw
Turn power off, wait until power
indicator stops blinking red, then
■ Lamp time reset procedure
unplug the power cord from the wall
outlet and confi rm that the area around
1Be sure the power cord is plugged into
the lamp unit has cooled down.
a properly grounded wall outlet. Then,
press the POWER button on the projection
display or the remote control to turn the
unit on.
Front cover
Lamp unit handle
2While pressing the VOL- button on
the projection display, hold down the
WARNING:
PIP button on the remote control at
The lamp may be hot. Be careful when handling.
same time for more than 5 seconds.
CAUTION:
• High-pressure lamp may explode if improperly
handled.
POWER
• Danger of injury due to glass fragments.
button
and
LAMP indicator
/POWER
3Loosen the Lamp cover screw.
First read caution and warning labels
indicator
on lamp cover. Then, loosen the lamp
5Insert the new lamp unit being careful
of the insertion direction.
cover screw by using a screwdriver.
• Press on the arrow mark making sure insertion is
done correctly.
• Please wait more than one hour for lamp
Lamp cover handle
Screwdriver
replacement.
3When reset
procedure is
LAMP TIME WAS
[If you need to replace the lamp more urgently]
complete, the
RESET TO 0.
• The Projection display has a forced cooling
screen on the right
feature. After the POWER button is turned OFF,
will appear.
and during the fi rst minute of the normal cooling
fan operation, press the VOL+ button on the
EXIT
projection display and ▲ button on the remote
control at same time for more than 5 seconds. The
cooling fan operates for about 10 minutes. The
6Replace the Lamp unit and cover
screws. Tighten the lamp unit/cover
LAMP indicator fl ashes red 5 times every 5
screw with a screwdriver.
Note
seconds.
• Properly dispose of old lamp.
When lamp time reset is fi nished, the LAMP
Lamp cover screw
Note
indicator goes out.
Attach the lamp unit and lamp unit housing door
CAUTION:
securely. If the lamp unit and lamp unit housing
[Under no circumstance should you touch the
door are not attached securely, the protective
actual bulb.]
circuit will be activated and the lamp will not turn
At this high operating temperature the natural oil
on.
on your fi nger can cause the glass to weaken
where touched and the bulb can crack or explode.
7Replace the Front cover.
LSQC0335
...