Войти:
Скачали: 19   Размер: 284 kb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

Refer to Figure 4-1. 1) Gently turn the valve counterclockwise. A stream of bubbles should appear at the base of the humidifier column, and the float of the flowmeter should rise in its tube. 2) Adjust the valve so that the flowmeter float is centered in the flow rate reference indicator. CAUTION: Open the throttle valve carefully. Excessive flow rate may cause water in the humidifier column to be carried into the detector cell. This can cause erratic readings and may require disassembly, cleani

Скачали: 39   Размер: 828 kb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

This Quickstart Guide should be used in conjunction with the Instruction Manual that shipped with your instrument. Only necessary features to get you operational are discussed in this guide. Many of the advanced features of this analyzer are not described here so you should refer to the Instruction Manual to get the most from your analyzer Front Panel (Operator Interface) Take a minute to familiarize yourself with the analyzer’s interface. The standard 3000TAEU is housed in a rugged metal case w

Скачали: 61   Размер: 687 kb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

• For vacuum service (5-10 in Hg), install the restrictor without the blue dot to the EXHAUST port. 2. Connect your sample gas to the SAMPLE IN port. 3. Connect a vent line to EXHAUST OUT port. Teledyne Analytical Instruments Model 3000TA Quickstart Guide 4. If using remote calibration feature: • Connect zero gas to the ZERO IN port. • Connect span gas to the SPAN IN port. 5. Otherwise, calibration gases must be Tee'd into the sample inlet with appropriate valves. 6. Regulate the sample gas pres

Скачали: 8   Размер: 125 kb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

. . TYPE B EQUIPMENT: Equipment providing a particular degree of protection against electric shock, particularly regarding— • allowable LEAKAGE CURRENT • Reliability of the protective earth connection (if present). P/N TM0021 04/03/00 ECO # 00-0086 TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments COPYRIGHT © 1996 TELEDYNE ELECTRONIC TECHNOLOGIES – ANALYTICAL INSTRUMENTS All Rights Reserved No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval sys

Скачали: 4   Размер: 51 kb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

Please refer to the Material Safety Data Sheet in the Appendix to learn about potential hazards and corrective action in case of accident. To install the cell: 1. Turn the unit off by placing the power switch (on the rear panel of the analyzer) in the OFF position. 2. Disconnect the red and black leads from the terminal strip. Remove the spent cell by pulling up on it and twisting slightly. 3. Remove the new Micro-Fuel Cell from its protective bag. CAUTION: Do not scratch, puncture, or damage th

Скачали: 7   Размер: 2 mb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

Hazardous voltages exist on certain components internally which may persist for a time even after the power is turned off and disconnected. Only authorized personnel should conduct maintenance and/or servicing. Before conducting any maintenance or servicing, consult with authorized supervisor/manager. Teledyne Analytical Instruments Model OT-3 Copyright © 2000 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retr

Скачали: 7   Размер: 651 kb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

P/N M75707 Sep 18, 2009 ECO 09-0157 MX300-I Copyright © 2009 Teledyne Analytical Instruments. All Rights Reserved No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, optical, manual, or otherwise, without prior written consent of Teledyne Analytical Instruments, 16830 Chestnut Street, City of Industry, CA

Скачали: 8   Размер: 579 kb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

In the inhalation side of breathing system upstream of any antibacterial filters, humidifiers and other such medicating devices. . In confined volumes such as in incubators or tents. When analyzing for oxygen in breathing systems, the flow diverter must be used. The diverter should be screwed onto the threaded front end of the R17MED sensor. A tee adapter (plastic, P/N A268, or metal, P/N A283) should be placed into the breathing loop, and the above sensor assembly plugged into the tee adapter.

Скачали: 48   Размер: 1 mb   Производитель: Teledyne  
Категория: Прочие персональные приборы
@name

The instrument has two simple operator controls. A digital meter, an alphanumeric display, and a sample flowmeter give the operator constant feedback from the instrument. See Figure 1-1. The controls are described briefly here and in greater detail in chapter 4. Figure 1-1: Model 3020T Controls, Indicators, and Connectors Teledyne Analytical Instruments 1 Introduction Model 3020T 1.5.1 UP/DOWN Switch Functions: The UP/DOWN switch is used to select the function to be performed. Choose UP or DOWN





Категории