Войти:
Оценок - 3, средний балл: 5 ( )

Инструкция по эксплуатации Centurion, модель MAGNUM M23/1000

Производитель: Centurion
Размер: 283.93 kb
Название файла: 2c5c7cb4-48e1-4d6c-9ed6-3a8feedf0212.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


GAS CANISTER The Canisters(s) must be changed at regular intervals as determined by a competent person or when any breakthrough of contaminate is detected by smell or taste. We recommend the following MAXIMUM environmental contamination levels for filters as defined by EN 12941/2. Class 1 Gas/Dust filters (e.g. M09A1/P2) = 500 ppm 200mg/m3 Class 2 Gas canisters (e.g. M23A2) = 1000ppm N/A Class 2 Gas combination/Dust canisters (e.g. M23 A2B2/P3) = 1000ppm 100mg/m3 Dust filters TH2P (e.g. M23P2/5) = N/A 400mg/m3 Dust filters TH3P/TM3P (e.g. M23P3/5) = N/A 200mg/m3 5.2 MAGNUM 1000, 2000 Power unit (M23/1000, M23/2000) Pre-filters (General) The pre-filter is an optional item, which sits in front of the main filter and removes coarse dust before it reaches the main filter. Pre-filters, in themselves, do not offer any respiratory protection and hence must only be used in conjunction with a main filter. The pre-filter should be changed immediately a drop in airflow is noticed. Frequent changing of the pre-filter will maximise the life of the main filter. Pre-filter Part number: M23PF/10 (For use with M23P2/5 & M23P3/5 filters only) Pre-filter replacement Outside surface of the power unit must be de-contaminated before changing the pre-filter Open the front cover of the Power unit by easing open the right hand side. Remove pre-filter with the minimum disturbance to the main filter. Locate pre-filter on top of main filter centrally and without overlapping Close the cover over the pre-filter/filter, taking care that it does not damage the filter media. Press down on the centre of the cover until it snaps closed. If a pre-filter is not used the main filter should be changed immediately the clogged filter alarm sounds/indicates or the air flow indicator, indicates reduced airflow. If a pre-filter is used it should be changed immediately the clogged filter alarm indicates or the airflow indicator, indicates reduced airflow. (This may be more frequently than if a pre-filter is not used). If after changing the pre-filter the clogged filter alarm sounds/indicates reduced airflow or the airflow indicator indicates reduced airflow. Within a short period of time, the main filter should be changed as detailed (see Main filter). MAGNUM 8500 2 or 3 Canisters(P3)2 2 or 3 Canisters(P3) 2 3 (Fitta)cartridge+adapters 3 3 Canisters(Din 40)* MAGNUM 2000 Cassette(P2)1 Cassette(P3)1 # # MAGNUM 1000 Cassette(P2)1 # # # PRE-FILTERS AVAILABLE : # = N/A 1 M23PF/10 (PARTICULATES ONLY) 2 M23PF/20 (PARTICULATES ONLY) 3 MO9PF ( PARTICULATES ONLY) *Pre-filters not available Mai n filters Part number: M23P2/5 or M23P2OD/5 THP2 /TH2P filters – for use with Magnum 1000 and 2000 Power Unit Part Number: M23P3/5 TH3P filter – For use with Magnum 2000 Power Unit only WARNING Care should be taken when handling filters. Do not touch the pleated paper filter medium. Do not use filters with damaged paper filter medium. Do not use filters after their expiry date. Do not use filters with no or damaged filter seal. Filters should be fitted as follows. : Remove the front cover by easing open the right hand side. Fit the filter squarely into the turbo unit. Place pre-filter over filter (if used). Close the cover over the filter, taking care that the cover does not touch the filter media. Press down on the centre of the cover until it snaps closed. MAGNUM 8500 Power unit M23/8500 Pre-filters (General) The pre-filter is an optional item, which sits in front of the main filter and removes coarse dust before it reaches the main filter. Pre-filters, in themselves, do not offer any respiratory protection and hence must only be used in conjunction with a main filter. The pre-filter should be changed immediately a drop in airflow is noticed. Frequent changing of the pre-filter will maximise the life of the main filter. Pre-filter Part number: M23PF/20 (For use with M23P3SL/6 only) Pre-filter replacement Ensure that the main filter(s) are securely in place before commencing this operation. Outside surfaces of both the power unit and the main filter(s) must be decontaminated before unscrewing the pre-filter retaining ring(s). Unscrew the pre-filter retaining ring(s) and remove the contaminated pre-filter(s). Replace the pre-filter(s) and re-fit the retaining ring(s). Pre-filter Part number: M09PF ( for use with M09 Fitta filters only) Pre-filter replacement Ensure that the main filter(s) are securely in place before commencing this operation. Outside surfaces of both the power unit and the main filter(s) must be de-contaminated before changing the pre-filter(s). The louver forms a prefilter holder on each filter. Lift the louver at the 2-pin catch, open it, and replace pre-filter in the recess on the top of the filter, ensuring that it lays flat. Close the louver and secure it on the 2-pin catch ensuring that it is properly snapped shut. If a pre-filter is not used the main filter should be changed immediately the clogged filter alarm sounds/indicates or the air flow ind...

Эта инструкция также подходит к моделям:
Прочие персональные приборы - MAGNUM M23/2000 (283.93 kb)
Прочие персональные приборы - MAGNUM M23/8500 (283.93 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории