Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Centurion, модель MAGNUM M23/2000

Производитель: Centurion
Размер: 283.93 kb
Название файла: 2c5c7cb4-48e1-4d6c-9ed6-3a8feedf0212.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


1. WARNINGS If these instructions are not followed or the unit is used incorrectly the system may not offer protection to EN12941/42 or EN 146. Power units offer NO protection unless a main filter(s) is fitted. In a power off situation the headpiece offers no respiratory protection and rapid CO2 build-up and oxygen depletion may also result. This is an abnormal situation. Power off is an abnormal situation regardless of whether a full hood, half suit or mask is used. At high work rates the pressure inside the headpiece may become negative at peak inhalation. The system should not be used in oxygen deficient or oxygen enriched atmospheres. The user must ensure that the nature of the hazard is identified and that the system offers an adequate level of protection. This unit should not be used where the nature of the hazard is unknown. This unit is NOT intrinsically safe and therefore should not be used in explosive atmospheres Be aware that the hose protrudes from the back of the headpiece and take care to avoid snagging. In high wind velocities the assumed protection levels may not be achieved. The full hood and half suit provide no protection against impact to head, face or eyes. Respiratory protection will be reduced unless the hood is correctly fitted and properly maintained. Do not confuse the markings on any filter which relate to standards other than EN12941 or EN12942 with the classification of this device when used with that filter. The classification for EN12941 will begin with "TH" and for EN12942 will begin with "TM". Filters should only be fitted to the power unit, do not attempt to fit them directly to a hood or helmet. 2. LIST OF PARTS , AVAILABLE HEADPIECES, APPROVALS / SPECIFICATION, NOMINAL AND ASSIGNED PROTECTION FACTORS kits Power Unit 8 hr Battery UK Charger Standard Class (5) M23/1000/CBM23/1000 M23P2/4B M23P2/4BC EN146 THP2 (3) (6) M23/2000/CBM23/2000 M23SPB M23UIC EN12941 TH2/TH3 (4) (1)(2) M23/8500/CB M23/8500 M23SPB M23UIC EN12941/2TH3/TM3TH2 (1) The M23/8500 and Full Facemask is approved with the full range of Martindale DIN 40 gas/combination filters. (2) The M23/8500 & TH2 headpieces are approved for use with the Fitta range of Combination Gas/Dust filters (M09A1P2) . (3) Optional 4 hour battery and charger available for the 2000 power units – M23P2/4B battery and M23P2/4BC charger. (4) All headpiece systems are to EN12941 or EN 146 with the exception of the Full facemask, which is to EN12942. (5) Note: Heavy Duty Battery M23HD4B and charger M23UIC are also available for use with the Magnum 1000 and will typically give durations of (6) 12 hours+. Note: Magnum 2000 only conforms to TH3 when used with M23P3/5 filters and M23LHF otherwise it conforms to TH2 (7) Note: Nominal Protection factors of headpieces used with Magnum 1000 is 20 Nominal and Assigned Protection Factors for Headpiece/Power Unit kits (Refer to Compatibility table below for suitable power units) NPF APF (UK) (1,2)(1,2) Headpiece code dust gases dust gases (7) Rigid Polycarbonate Visor with Saronex Hood M23RVSN 5050 20 20 (7) Flip up Polycarbonate Visor M23FUVN 5050 20 20 (7) Helmet with Flip-up Polycarbonate Visor M23HFUV 5050 20 20 (7) High Temperature Helmet with Clear Triacetate Flip up Visor M23HFUVHTT 5050 20 20 (7) High Temperature Helmet with Gold Polycarbonate Visor M23HFUVHTGP 5050 20 20 (7) Automatic Welding Visor M23AWSN 5050 20 20 (7) Fixed Shade Welding Visor M23FSWVN 5050 20 20 Lightweight P3 Tyvek F Hood M23LHF 50/500* 50/500* 20/40* 20/40* Full Hood M23FH/8 500 -40 - Half Suit M23HS/8 500 -40 - Full facemask with twin hose M23FF 2000 2000 40 40 * Note NPF=500 & APF=40 when M23LHF is used with TH3P Filters (e.g. M23P3/5 or M23P3SL/6) and M23/2000 or 8500 otherwise the M23LHF (7) has NPF=50& APF=20. A detailed table showing the exact classifications and protection levels is given in the headpiece instructions (024-001-692) supplied with each headpiece which must be read in conjunction with these instructions. 024-001-750 MOD 8 11/05/07 Page 1 of 8 POWER UNITS Centurion Safety Products Ltd. Howlett Way, Thetford, Norfolk, IP24 1HZ, UK Tel. 0044 (0)1842 754266 Fax. 0044 (0)1842 765590 Compatibility between Headpieces and Power Units: Headpieces: Power Units: Description Code 1000/2000 8500 Rigid Polycarbonate Visor with Saronex Hood M23RVSN • Flip up Polycarbonate Visor M23FUVN • Helmet with Flip-up Polycarbonate Visor M23HFUV • High Temperature Helmet with Clear Triacetate Flip up Visor M23HFUVHTT • High Temperature Helmet with Gold Polycarbonate Visor M23HFUVHTGP • Automatic Welding Visor M23AWSN • Fixed Shade Welding Visor M23FSWN • Full Facemask with Twin Hose M23FF x • Full Hood without airflow indicator M23FH/8 x • Half Suit without airflow indicator M23HS/8 x • Lightweight P3 Tyvek F M23LHF • 3. APPLICATIONS AND LIMITATIONS When used with filters M23P3/5, M23P2/5 or M23P3SL/6 the Magnum respirator will offer protection against dusts, particles, fumes and aerosols (solid and liquid based) to the le...

Эта инструкция также подходит к моделям:
Прочие персональные приборы - MAGNUM M23/1000 (283.93 kb)
Прочие персональные приборы - MAGNUM M23/8500 (283.93 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории