Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Northern Industrial Tools, модель 142262

Производитель: Northern Industrial Tools
Размер: 1.38 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If you are unable to hoist a load and the load is under the maximum lift capacity, stop the Hoist and allow the motor to cool down before trying again. 18. Make sure the cable is correctly wound around the wheel. See FIGURE 1 below. 19. Do not support a load over or around people or animals. 20. Do not leave load suspended in the air unattended. 21. Do not allow a load to bear against the hook latch. Allowing a load to bear against the hook latch can result in loss of load. 22. Do not allow load to swing or twist while hoisting. 23. Do not use cable as a sling or wrap cable around a load. PAGE 6 WARNING! People with pacemakers should consult their physician(s) before using this product. Operation of electrical equipment in close proximity to a heart pacemaker could cause interference or failure of the pacemaker. GROUNDING WARNING! Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician. GROUNDED TOOLS: TOOLS WITH 3- PRONG PLUGS 1. Tools marked with “Grounding Required” have a 3-wire cord and 3-prong grounding plug. The plug must be connected to a properly grounded outlet. If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock. (See Figure A.) 2. The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” terminal. (See Figure A.) 3. Your tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in the following illustration. (See Figure A.) PAGE 7 DOUBLE INSULATED TOOLS: TOOLS WITH TWO PRONG PLUGS 4. Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Figure B.) 5. Double insulated tools may be used in either of the 120 volt outlets shown in the following illustration. (See Figure B.) EXTENSION CORDS 1. Grounded tools require a 3-wire extension cord. Double Insulated tools can use either a 2- or 3-wire extension cord. 2. As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. 3. The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14- gauge cord can carry a higher current than a 16- gauge cord. 4. When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required. 5. If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. PAGE 8 6. If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use. 7. Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it. 8. Protect your extension cords from sharp objects, excessive heat, and damp or wet areas. SYMBOLOGY Table A UNPACKING When unpacking, check to make sure all the parts shown on the Parts List on page 12 are included. If any parts are missing or broken, please call Northern Tool + Equipment Customer Service at 1-800-222-5381. PAGE 9 FIGURE 2 ASSEMBLY AND OPERATING INSTRUCTIONS Hoist Set-up WARNING! Unplug the Hoist before set-up. 1. This Hoist is designed to be attached to a beam or steel pipe and bed securely held in place by both of the Hangers (#23). See FIGURE 2. Note: The beam or steel pipe must be capable of carrying several times the weig...

Эта инструкция также подходит к моделям:
Прочие персональные приборы - 14226 (1.38 mb)
Прочие персональные приборы - 142260 (1.38 mb)
Прочие персональные приборы - 14230 (1.38 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории