Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Invacare, модель IRC5LX

Производитель: Invacare
Размер: 754.33 kb
Название файла: 1118353.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


DO NOT disassemble. Refer servicing to qualified service personnel. No user serviceable parts. Avoid using while bathing. If continuous usage is required by the physician’s prescription, the concentrator MUST be located in another room at least 7 ft from the bath. DO NOT come in contact with the concentrator while wet. DO NOT place or store product where it can drop into water or other liquid. DO NOT reach for product that has fallen into water. Unplug IMMEDIATELY. If the concentrator has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water, call qualified technician for examination and repair. A spontaneous and violent ignition may occur if oil, grease or greasy substances come in contact with oxygen under pressure. These substances MUST be kept away from the oxygen concentrator, tubing and connections, and all other oxygen equipment. DO NOT use any lubricants unless recommended by Invacare. Avoid creation of any spark near medical oxygen equipment. This includes sparks from static electricity created by any type of friction. Platinum™ Series 8 Part No 1118353 SECTION 1—GENERAL GUIDELINES Operating Information For optimum performance, Invacare recommends that each concentrator be on and running for a minimum of 30 minutes at a time. Shorter periods of operation may reduce maximum product life. Keep the oxygen tubing, cord, and unit out from under such items as blankets, bed coverings, chair cushions, clothing and away from heated or hot surfaces, including space heaters, stoves and similar electrical appliances. DO NOT move or relocate concentrator by pulling on the power cord. NEVER drop or insert any object or liquid into any opening. Invacare recommends that Crush.Proof oxygen tubing be used with this product and not exceed 15.2 m (50 ft) in length. There are no user serviceable parts. This does not include normal maintenance items. See maintenance section for user maintenance items. A product should NEVER be left unattended when plugged in. Make sure the Platinum is Off when not in use. Close supervision is necessary when this product is used near children or physically.challenged individuals. Additional monitoring or attention may be required for patients using this device who are unable to hear or see alarms or communicate discomfort. DO NOT connect the concentrator in parallel or series with other oxygen concentrators or oxygen therapy devices. Radio Frequency Interference This equipment has been tested and found to comply with EMC limits specified by IEC/EN 60601.1.2. These limits are designed to provide a reasonable protection against electromagnetic interference in a typical medical installation. Part No 1118353 9 Platinum™ Series SECTION 1—GENERAL GUIDELINES Other devices may experience interference from even the low levels of electromagnetic emissions permitted by the above standards. To determine if the emissions from the Platinum is causing the interference, turn the Platinum Off. If the interference with the other device(s) stops, then the Platinum is causing the interference. In such rare cases, interference may be reduced or corrected by one of the following measures: •Reposition, relocate, or increase the separation between the equipment. Connect the equipment into an outlet on a circuit different from that to which the other device(s) is connected. Platinum™ Series 10 Part No 1118353 SECTION 2—FEATURES SECTION 2—FEATURES Oxygen Outlet Flowmeter REAR VIEW Power Cord OutletFitting Oxygen Purity Indicator Lights (SensO2 model only)/ Fault and Power Indicator Lights (LX model only) Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter (one of two shown) ACCESSORIES (NOT SHOWN): Remote Humidifier/Flowmeter Accessory - IRCRF5 (Platinum 5 and XL Only) PreciseRX™ Pediatric Humidifier/Flowmeter Accessory - IRCPF16 (Platinum 5 and XL Only) HomeFill home oxygen compressor - IOH200 NOTE: This outlet fitting is to be used only for filling oxygen cylinders with the HomeFill home oxygen compressor. The outlet fitting does not affect concentrator performance. Refer to the HomeFill owner.s manual, part number 1100873, for connection and operating instructions. When not in use, the plug provided with the concentrator should be inserted into the outlet fitting. For more information about the HomeFill, contact your Invacare dealer. Part No 1118353 11 Platinum™ Series SECTION 3—HANDLING SECTION 3—HANDLING The concentrator should ALWAYS be kept in the upright position to prevent cabinet damage while being transported. If the concentrator is to be reshipped by common carrier, additional cartons are available from Invacare. Unpacking NOTE: For this procedure, refer to FIGURE 3.1. 1. Check for any obvious damage to the carton or its contents. If damage is evident, notify the carrier, or your local dealer. 2. Remove all loose packing from the carton. 3. Carefully remove all the components from the carton. FIGURE 3.1 Unpacking NOTE: Unless the oxy...

Эта инструкция также подходит к моделям:
Прочие персональные приборы - IRC10LX (754.33 kb)
Прочие персональные приборы - IRC10LXO2 (754.33 kb)
Прочие персональные приборы - IRC5LXO2 (754.33 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории