Войти:
Сортировка : Названию ↑   Загрузкам   Оценке   Размеру ↑  
Скачали: 6   Размер: 3 mb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

The options for this menu item are: • “SIGNAL > SETPOINT” means the limit will activate when the signal is higher than the set point. • “SIGNAL < SETPOINT” means the limit will activate when the signal is lower than the set point. • “SIGNAL INSIDE” means the limit will activate when the signal is in between the set point and the return point. • “SIGNAL OUTSIDE” means the limit will activate when the signal is not in between the set point and the return point. The figures below further illustrate

Скачали: 10   Размер: 197 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

14. Two T7047G1000 Sensors providing a temperature-averaging network for a T7300/Q7300 Thermostat/Subbase. Q7300 T T M3422 T T T7047GT T T7047G T T T7047G T T T7047G T T T7047G Fig. 15. Five T7047G1000 Sensors providing a temperature-averaging network for a T7300/Q7300 Thermostat/Subbase. Q7300 T T M3419 T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C Fig. 16. Nine T7047C1025 Sensors providing a temperature-averaging network for a T7300/Q7300 Th

Скачали: 4   Размер: 145 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

Its primary use is with the T7300 Programmable Commercial Thermostat (only in return air) to control heating or cooling equipment. NOTE: The T7022 can also be used with a T7100F, provided the proper Q7100 subbase—one capable of handling more than one stage of heat—is used. IMPORTANT All wiring must agree with applicable codes, ordinances and regulations. Wiring (Fig. 1) Wiring for the T7022 Remote Temperature Sensor can be run with class 2 wire in accordance with the National Electrical Cod

Скачали: 10   Размер: 477 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name@name@name

• there is good air circulation. • it can measure true outdoor ambient temperature. • surface is flat. • wire distance between C7089 and thermostat is less than 200 feet. Do not mount the sensor: • in direct sunlight. • where hot or cold air blows on the sensor. Discharge line from an outdoor compressor unit, vent or fan causes inaccurate temperature readings. • where snow, ice or debris can cover it. Use the following steps to mount the sensor: 1. Remove the sensor from the mounting clip. 2. Ma

Скачали: 0   Размер: 362 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

CAUTION This product is not intended to be used for life or safety applications. CAUTION This product is not intended for use in any hazardous or classified locations. INSTALLATION Make sure that all installations are in compliance with all national and local electrical codes. Only qualified individuals that are familiar with codes, standards, and proper safety procedures for high-voltage installations should attempt installation. The current sensor is a 2- wire, 4 to 20 mA Loop Powered device t

Скачали: 8   Размер: 507 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name@name

Debe insertar un cable en el terminal OT 1 y el otro cable en el terminal OT. MODULO DE INTERFAZ DE SENSOR PARA EXTERIORES (50022037) EXTERIOR C70809U MS23812 OT 1 PANEL W8835 SENSOR DE TEMPERATURA 2 3 1 2 3 OT Fig. 1. Diagrama de conexion del modulo de interfaz desensor para exteriores. OUTDOOR SENSOR INTERFACE MODULE OUTDOOR SENSOR INTERFACE MODULE Honeywell International Inc. Honeywell Limited-Honeywell Limitee 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario

Скачали: 1   Размер: 2 mb   Производитель: Honeywell  
Категория: Прочие инструменты
@name@name@name

Once a remote indoor temperature sensor is connected to the thermostat, the thermostat’s sensor is no longer used. The thermostat’s installer setup should be modified to tell the thermostat that remote indoor temperature sensor(s) have been used. The Inside temperature reading on the thermostat’s display will be the remote sensor(s) temperature location(s). Fig. 1. C7189U Remote Indoor Sensor SPECIFICATIONS Operating Ambient Temperature Range: 45 to 88°F (7.2 to 32°C). Display Range: 0 to 99°F (

Скачали: 3   Размер: 3 mb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

page 108 008-0608-00 Each High-Level Input channel is configured and calibrated via its channel menu. Detailed instructions on operating the instrument in the SETUP Menu mode can be found in “SETUP Menu mode” on page 23. A diagram of all menus is located in “Setup Menu Reference” on page 157. 12.6.1 OPERATION Sub-Menu This menu controls the operation of this channel when the instrument is in the RUN mode. AUTO-ZERO Menu Item This enables or disables the channel’s automatic zeroing function. The

Скачали: 2   Размер: 140 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

1 Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. INSTALLATION INSTRUCTIONS 3 Installer must be a trained, experienced service technician. 4 After installation is complete, check out product operation as provided in these instructions. CAUTION Disconnect power supply before connecting wiring to prevent elect

Скачали: 1   Размер: 334 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

63-2150—5 2 C7600A SOLID STATE HUNIDITY SENSOR 20 18 16 14 12 10 8 6 4 0 CURRENT IN mA HUMIDITY IN % RH M3130 Fig. 2. C7600A output current vs. relative humidity. INSTALLATION When Installing this Product… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. Checkout





Категории