Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Grizzly, модель G0638

Производитель: Grizzly
Размер: 8.17 mb
Название файла: 4453f04c-ca41-4174-9862-ea59fac5ea77.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Remedy the metal to metal contact problem before resuming operation. 7. OPERATIONAL QUESTIONS. If at any time you are experiencing difficulties performing the intended operation, stop using the machine! Then contact our Tech Support or ask a qualified expert how the operation should be performed. 8. CLEANING AIR. Do not confuse this dust collector with an air cleaner. This dust collector is only designed to collect dust from a machine, not clean dust suspended in the air. 9. EMPTYING DUST. When emptying dust from the collection bags or drum, wear a respirator and safety glasses. Empty dust into an approved container and dispose of properly. Awarning Like all machines there is danger associated with this dust collector. Accidents are frequently caused by lack of familiarity or failure to pay attention. Use this machine with respect and caution to lessen the possibility of operator injury. If normal safety precautions are overlooked or ignored, serious personal injury may occur. Acaution No list of safety guidelines can be complete. Every shop environment is different. Always consider safety first, as it applies to your individual working conditions. Use this and other machinery with caution and respect. Failure to do so could result in serious personal injury, damage to equipment, or poor work results. -10- G0637/G0638 Cyclone Dust Collector SECTION 2: CIRCUIT REQUIREMENTS ▲WARNING Serious personal injury could occur if you connect the machine to the power source before you have completed the set up process. DO NOT connect the machine to the power source until instructed to do so. Full Load Amperage Draw G0637 71/2 HP 220V 3-Phase...............25 Amps G0637 7V2 HP 440V 3-Phase............12.5 Amps G0638 10 HP 220V 3-Phase.................30 Amps G0638 10 HP 440V 3-Phase.................15 Amps Circuit Requirements We recommend connecting your machine to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician. G0637 7V2 HP 220V 3-Phase.................40 Amp G0637 7V2 HP 440V 3-Phase.................20 Amp G0638 10 HP 220V 3-Phase...................40 Amp G0638 10 HP 440V 3-Phase...................20 Amp Connection to Power Have a qualified electrician hardwire this machine to a dedicated locking shut-off switch (see Figure 2) that is connected to the main power source. ▲warning Electrocution or fire could result if this machine is not grounded correctly or if your electrical configuration does not comply with local and state codes. Ensure compliance by checking with a qualified electrician! Phase Converter When using a phase converter, the power from the manufactured power leg (sometimes called the wild wire) can fluctuate. Connect the manufactured power leg to the 3L/2 terminal to prevent damage to the IC board or transformer. The wire from this terminal can handle some fluctuation because it goes directly to the motor. The power going to the 1L/2 and 5L/3 terminals goes to the IC board and transformer and must be consistent to prevent damage. G0637/G0638 Cyclone Dust Collector -11- Model G0637 440V Conversion The Model G0637 can be rewired for 440V operation. This rewiring job consists of disconnecting the dust collector from the power source, changing the control box, and rewiring the motor. The necessary control box for this procedure can be purchased by calling our customer service number at (800) 523-4777 and ordering part number P0637119. When complete, the rewiring job must be inspected by a qualified electrician before the dust collector is connected to the power source. Refer to the Wiring Diagrams on Pages 45-46 for additional information. Model G0638 440V Conversion To operate the Model G0638 on 440V power, you must purchase a G0638 440V Conversion Kit. Call our customer service number at (800) 5234777 and order part number P0638119. To convert the G0638 to 440V: 1. DISCONNECT THE DUST COLLECTOR FROM THE POWER SOURCE! 2. Open the control box and identify the overload relay and the transformer (see Figure 3). Figure 3. Model G0638 control box overload relay and transformer. 3. Replace the overload relay with the one included in the conversion kit, and turn the AMP dial to 15. 4. Move the "R0" wire on the transformer from the 220V terminal to the 440V terminal (see Figure 4). transformer connections. 5. Open the motor junction box and rewire the motor terminals for 440V power. Refer to Wiring Diagram on Page 48 for additional information. ▲WARNING You must have a qualified electrician inspect your 440V rewiring job before connecting the dust collector to the power source. Failure to heed this warning may result in property dama...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории