Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Dynasty Spas, модель SC-MP-DY5

Производитель: Dynasty Spas
Размер: 223.78 kb
Название файла: Classic-Series-Dual-Pump-QRC.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Pressing a second time turns Pump 1 and Pump 2 to high speed. A third time turns both pumps off. A built-in timer automatically turns pumps off after 20 minutes (Pump 1 low speed after 2 hours), unless manually deactivated first. The "Pump 1" indicator flashes when Pump 1 is on at low speed. "Pump 1" and "Pump 2" indicators light up when both pumps are on at high speed. Starting the blower: Press Blower once to turn blower on. Pressing a second time turns blower off. A built-in timer automatically turns blower off after 20 minutes, unless manually deactivated first. The "Blower" indicator lights up when blower is on. Setting water temperature: Use Up or Down arrow keys to regulate water temperature. The temperature setting will be displayed for 5 seconds to confirm your new selection. The "Set Point" indicator displays the desired temperature, NOT the current water temperature! Water temperature can be adjusted by 1. increments from 59 to 104.F (15 to 40.C). Temperature display unit: Press and hold Light key for 5 seconds to display water temperature in either Fahrenheit (.F) or Celsius (.C). If a power-up occurs, system returns to default setting (.F). Turning the light on: Press Light to turn light on. Pressing a second time turns light off. A built-in timer automatically turns light off after 2 hours, unless manually deactivated first. The "Light" indicator is displayed when light is on. Fiber Box Option: If spa has an optional fiber box, press Light key to turn fiber box (motor and light) on. Pressing a second time turns fiber box off but leaves light on. A third time turns both motor and light off. A built-in timer turns fiber box off after 2 hours, unless it has been manually deactivated. The "Light" indicator is displayed when fiber box light is on. It flashes when fiber box motor and light are on at the same time. LED Light Option: If spa has an optional LED light, press Light key to turn LED lights on. To advance to the next color/display setting, press Light key twice. The LEDs will go off with the first press, then back on in the next setting with the second press. If the LEDs remain off for more than 5 sec., the color/ display sequence will reset and start back at the beginning the next time the Light key is pressed. Color/ display sequences are: 1• LEDs light up and slowly cycle through all six colors. The slow cycle restarts at the beginning and repeats. 2• LEDs light up and remain on in Aqua. 3• LEDs light up and remain on in Purple. 4• LEDs light up and remain on in Blue. 5• LEDs light up and remain on in Gold. 6• LEDs light up and remain on in Green. 7• LEDs light up and remain on in Red. 8• LEDs light up for 2 sec., flash off, then flash on in the next color until all six colors have been displayed. The flashing cycle then repeats itself. 9• LEDs flash on/off quickly for a strobe light effect. A built-in timer turns lights off after 2 hours unless manually deactivated first. The "Light" icon is displayed when LED light is on. QuickReferenceCard Automaticwaterheaterstart: Economymode: When water temperature is 1.F (0.5.C) lower than Press Econo key to switch from Normal mode the Set Point, the heater will automatically turn on until to Economy mode. In Economy mode, system water temperature reaches Set Point plus 1.F (0.5.C). maintains temperature at the desired Set Point during filter cycles only. Set Point is 20.F (11.C) The "Heater" indicator lights up when the heater is below the Normal mode Set Point for the rest on. It flashes when there is a request for more of the time. In Economy mode, the display will heat but the heater has not yet started. toggle between the current water temperature and the "Econ" message. N.B.: If your system is configured in Low Current Mode, the heater will not start if a pump is on at high speed. PROGRAMMINGFILTERCYCLEDURATION The system automatically performs two filter cycles per day, at 12-hour intervals. During a filter cycle: Pump 2 and blower run for one minute, then Pump 1 runs at low speed for the programmed number of hours The "Filter Cycle" indicator lights up when the filter cycle is on. To set filter cycle duration: Press and hold Filter key until the display shows "xx", representing the currently set filter cycle duration in hours. The filter cycle is suspended if the water temperature raises more than 2.F (1.C) above Set Point or if spa is in use (pumps, blower started manually). The "Filter" indicator will blink (on 0.5 second, off 0.5 second, on 0.5 second, off 1.5 seconds). TROUBLESHOOTING Use Up or Down arrow keys When the desired setting to change setting. is displayed, press Filter key 0 = no filtration again to confirm. A filter cycle 12 = continuous filtration starts immediately. N.B.: After a power failure, the filter cycle duration will return to its default value (2 hours). In this case, the first filter cycle will start one minute after power has been restored. Not a bug but a feature! Our Smart Winter Mode protects your spa from t...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории