Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Hatco, модель GLO-RAY GRAL

Производитель: Hatco
Размер: 425.8 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


WARNING Units equipped with a cord and plug supplied by Hatco must be plugged into a properly grounded electrical outlet of the correct voltage, size and plug configuration. If the plug and receptacle do not match, contact a qualified electrician to determine the proper voltage and size and install the proper electrical outlet. NOTE: Units intended for fixed or permanent mounting cannot have a power cord attached and must be hard wired according to local and national electrical codes. Form No. GRM-0707 18 INSTALLATION Remote Mounted Control Box (RMB) Hatco Remote Mounted Control Boxes include switches, wire leads and/or indicator lights and are ready for installation. Proper use of RMB’s require one RMB per strip heater. NOTICE To prevent premature failure to components the Remote Control Box (RMB) must be installed outside the foodwarmer heat zone. Control Switches When two or more units are mounted where the heat from one housing tends to raise the temperature of another, the control switches should be installed in a remote control enclosure. Units in a multiple installation should use remote control enclosures. NOTE: Remote control enclosures are available in five sizes. All models are built in accordance with U.L. standards to accommodate switches, indicator lights and wiring, ready for installation. See ACCESSORIES at the back of this manual. OPERATION CAUTION Some exterior surfaces on the unit will get hot. Use caution when touching these areas to avoid injury. WARNING The unit is not waterproof. DO NOT submerge in water. Do not operate if it has been submerged in water. CAUTION Standard and approved manufacturing oils will smoke up to 30 minutes during initial start-up. This is a temporary condition. To assure safe operation, operate unit without food product until smoke dissipates. Heating Element(s) Heating element(s) are controlled by an ON/OFF toggle switch(es) or an optional infinite switch(es). To turn each element on, either flip the toggle switch to the ON position or turn the adjustable switch to the desired setting. Allow 15-20 temperature. minutes to reach operating NOTE: Remote control enclosures are recommended for all Glo-Ray units. Optional Infinite Control Toggle Switch (On/Off) Indicator Light Figure 23. Remote Control Box (RMB) (RMB-7 Series Shown) Lights On models equipped with lights, flip the toggle switch to the ON position to energize the lights. NOTE: Dual Glo-Ray units do not use a built-in infinite switch. 19 Form No. GRM-0707 MAINTENANCE CLEANING Hatco Glo-Ray® Strip Heater units are designed for maximum durability and performance, with minimum maintenance. WARNING To avoid any injury or damage to the strip heater turn the power OFF at the disconnect switch/circuit breaker and allow to cool before performing any maintenance. To preserve the finish of the Glo-Ray Strip Heater, it is recommended that the surfaces be wiped daily with a clean, soft, damp cloth. Stubborn stains maybe be removed with a good stainless steel cleaner or a non-abrasive cleaner. Hard to reach areas should be cleaned with a small brush and mild soap. NOTICE Use only non-abrasive cleaners. Abrasive cleaners could scratch the finish of your unit marring its appearance and making it susceptible to soil accumulation. DISPLAY LIGHT BULB REPLACEMENT The display light is an incandescent bulb which illuminates the warming area. This bulb has a special coating to guard against injury and food contamination in the event of breakage. To replace a bulb, disconnect the power supply and wait until the unit has cooled. Display lamps have a threaded base. Unscrew the bulb from the unit and replace it with a new specially coated incandescent bulb. Hatco shatter-resistant bulbs meet NSF standards for food holding and display areas. NOTE: Hatco shatter-resistant light bulbs meet NSF standards for food holding and display areas. For 120, 120/208, 120/240 and 100/200 Volt applications, use Hatco part number 02.30.043.00. For 200, 220, 230 and 240 Volt units use Hatco part number 02.30.058.00. WARNING Only light bulbs which meet or exceed NSF standards, specially designed for food holding areas may be used. Breakage of light bulbs not specially coated could result in personal injury and/or food contamination. WARNING If service is required on this unit, contact your Authorized Hatco Service Agent, or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966 or International fax 414-671-3976. WARNING This product has no “user” serviceable parts. To avoid damage to the unit or injury to personnel, use only Authorized Hatco Service Agents and Genuine Hatco Replacement Parts when service is required. WARNING Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used. Some aftermarket or generic replacement parts do not have the characteristics that will allow them to operate safely in Hatco equipment. It is essential to use Hatco Replacement Parts when...

Эта инструкция также подходит к моделям:
Принтеры - GLO-RAY GRA (425.8 kb)
Принтеры - GLO-RAY GRAHL (425.8 kb)
Принтеры - GLO-RAY GR (425.8 kb)
Принтеры - GLO-RAY GRAH (425.8 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории