Инструкция по эксплуатации Ei Electronics, модель Ei100B

Производитель: Ei Electronics
Размер: 186.17 kb
Название файла: f6dbfc99-107a-4502-af2b-9aa02f80b7c1.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Note: . When the battery is first connected the Alarm may sound for 2-3 seconds - this is normal. . A Smoke Alarm does not prevent fires. . Install correctly, in the center of the ceiling if possible. . Test weekly. . Replace battery yearly or when it beeps once a minute. . Plan your escape route. . Proper protection may require more than one Smoke Alarm. . If you have any doubt or query about Smoke Alarms consult the supplier or your local Fire Brigade. . Nuisance alarms can be quickly silenced by fanning with a newspaper or similar to help remove smoke from the unit. Locating your Smoke Alarm Sufficient smoke must enter your Smoke Alarm before it will respond. Your Smoke Alarm needs to be within 10 paces (23 feet) of the fire to respond quickly. It also needs to be in a position where its alarm can be heard throughout your home, so it can wake you and your family in time for you all to escape. A single Smoke Alarm will give some protection if it is properly installed, but most homes will require two or more to ensure that a reliable early warning is given. For maximum protection you should put individual Smoke Alarms in all the rooms where fire is most likely to break out. Your first Smoke Alarm should be located between the sleeping area and the most likely sources of fire (living room or kitchen for example). But it should not be more than 10 paces (seven metres) from the door to any room where a fire might start and block your escape from the house. (a) Single Storey Dwelling. If your Home is on one level (a bungalow or mobile home for example) you should put your first Smoke Alarm in a corridor or hallway between the sleeping and living areas. Place it as near to the living area as possible, but make sure you can hear it loudly enough to wake you in the bedroom. (for example, see figure 1) If your bungalow is very large and the corridor or hallway is more than say 22 paces (15 metres) long, one Smoke Alarm will not be sufficient. This is because no matter where it is located it will be more than 7.5 metres from potential fires. In houses with more than one sleeping area, Smoke Alarms should be placed between each sleeping area and the living area (for example, see figure 2). 2 Figure 2: Single Storey Dwelling with seperate sleeping areas BEDROOM BEDROOM LIVING BEDROOM RECREATION DININGKITCHEN Figure 3: Two Storey Dwelling BEDROOM BEDROOM BEDROOM KITCHEN DINING Figure 1: Single Storey Dwelling Recommended protection, Figures 1,2 & 3 Minimum protection each storey each sleeping area every 7.5 metres (25ft) of hallways and rooms Maximum protection All rooms (except bathrooms & kitchens) This is because an upstairs smoke alarm is unlikely to detect a fire on lower floors in sufficient time to ensure an adequate escape. (c) Maximum Protection. For maximum protection you should put individual Smoke Alarms in all the rooms where fire is most likely to break out (apart from the locations to avoid, mentioned on page 5). The living room is the most likely place for a fire to start at night, followed by the kitchen and then the dining room. You should also consider putting Smoke Alarms in any bedrooms where fires might occur, for instance, where there is an electrical appliance such as an electric blanket or heater, or where the occupant is a smoker. You could also consider putting Smoke Alarms in any rooms where the occupant is unable to respond very well to a fire starting in the room, such as an elderly or sick person or a very young child. (d) Checking you can hear your Smoke Alarm. With the Smoke Alarm sounding in its intended location, check you are able to hear it in each bedroom with the door closed, above the sound of your radio. The radio should be set to a reasonably loud conversation level. If you can’t hear it over your radio the chances are that it wouldn’t wake you. If a Smoke Alarm is too far away for it to wake you, it is best to link it to another Smoke Alarm near the bedroom. The Interconnect Smoke Alarm EI 100C is designed for this - when one alarm senses smoke, all connected alarms respond. (see page 9 for further details). Positioning your Smoke Alarm Figure 5 Figure 4 IDEAL IN CENTRE 90cm(3 FEET) DEAD AIR SURFACES NEVER WITHIN 15cm OF ANY CORNER 15 TO 30cm (6 to 12") OF CEILING (a) Ceiling Mounting. Hot smoke rises and spreads out, so a central ceiling position is the preferred location. The air is “dead” and does not move in corners, therefore Smoke Alarms must be mounted away from (b) Multi Storey Dwellings. corners. Place the unit at least 30cm (12 inches) from any light If your home is on more than one level you will require a smoke fitting or decorative object which might obstruct smoke entering alarm on each storey (see figure 3). 34 P/N B10277 - Pages 2 to 5 - Rev 7 the Smoke Alarm. Keep at least 15 cm (6 inches) away from walls and corners. See figure 4. (b) Wall Mounting. When a ceiling position is not practical (for example on a ceiling having exposed beams or joists, or built...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории