Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Hobart, модель C44AW ML-103946

Производитель: Hobart
Размер: 1.56 mb
Название файла:
Язык инструкции:
Перейти к скачиванию



Фрагмент инструкции


– 24 – MAINTENANCE WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. Some machines may have more than one electrical power supply. All supplies MUST be disconnected. VENT When cool, check the vent of this dishwasher every six months for obstructions. LUBRICATION None required. SERVICE Contact your local Hobart Service office for any repairs or adjustments needed on this equipment. If a gas orifice fitting is to be adjusted or replaced, have it serviced by qualified Hobart Service personnel. Long-term service contracts are available on this and other Hobart products. – 25 – TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE No Machine Operation. 1. Blown fuse or tripped circuit breaker at power supply. 2. Inspection door(s) not closed. 3. Conveyor jammed. 4. If Auto Timer was used, the timer may have timed out. 5. If table limit switch is used, the switch may be tripped. 6. Manual overload protector tripped on pump motors or conveyor motor. Dishes Not Clean. 1. Insufficient wash water due to drain obstruction preventing proper drain closing. 2. Worn or torn drain O-ring allowing wash water to drain. 3. Missing end plug from wash arm. 4. Wash arm nozzle obstruction. 5. Water leaking past manifold O-ring. 6. Loss of water pressure due to pump obstructions. DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. Drain tank(s) and check for any obstruction at the pump intake. 7. Incorrect water temperature. Check circuit breaker to electric heat supply, or main steam valve. Make certain valve is completely open. 8. Incorrect detergent dispensing. Contact your detergent representative. 9. Strainer pans/buckets need to be emptied and/or cleaned. Leaking Valve (Except Solenoid Type) Supplied by Others. 1. Foreign material preventing proper valve operation. A critical period is soon after installation when pipe compound or metal shavings may lodge at the valve seat. Shut off supply line. Unscrew and lift bonnet from valve body. Clean valve and reassemble. 2. If problem is with a solenoid valve, it is recommended that you contact your local Hobart Service office. Spotting of Silverware, 1. Improperly loaded racks. Glasses and Dishes. 2. Incorrect final rinse water temperature (180°F min.). 3. Loss of water pressure due to pump obstruction. DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. Drain tank(s) and check for any obstruction at the pump intake. 4. Clogged wash arm nozzles. 5. Improper water hardness (4 to 6 grains/gallon is the recommended range). 6. Incorrect detergent for water type. 7. Clogged rinse nozzle(s). Low Final Rinse Temperature 1. Tank float not "up" to allow heat to turn on. With Booster Heater. 2. Overtemp protector tripped. 3. Circuit breaker to heat system tripped. 4. Incoming water is below minimum temperature. 5. Temperature control needs adjustment or booster heater f...

Эта инструкция также подходит к моделям:
Посудомоечные машины - C44AW ML-104083 (1.56 mb)
Посудомоечные машины - C44A ML-104047 (1.56 mb)
Посудомоечные машины - C44A ML-104050 (1.56 mb)
Посудомоечные машины - C44A ML-38898 (1.56 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории