Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации England's Works, модель 26-GBVLP

Производитель: England's Works
Размер: 289.42 kb
Название файла: 6c59d6be-e24a-4baf-95cc-de4fb90049e6.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Save These Instructions Questions? Need Parts or Options? Please Note the Following Precautionary Statements: NOTE: THIS UNIT IS NOT A DIRECT VENT STOVE AND THEREFORE REQUIRES 4” B-VENT GAS PIPE WITH ONE INCH (1”) CLEARANCE TO COMBUSTIBLES. THIS STOVE IS NOT APPROVED FOR MOBILE HOME OR DOUBLEWIDE INSTALLATION. DO NOT INSTALL THIS UNIT IN A BEDROOM. Text Box: Text Box: UWARNINGU: READ THIS MANUAL PRIOR TO INSTALLATION OF THE UNIT. IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO AND SAVE THIS MANUAL. CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR YOUR GAS COMPANY BEFORE INSTALLATION. Text Box: UWHAT TO DO IF YOU SMELL GAS •DO NOT TRY TO LIGHT ANY APPLIANCE. OPEN ALL WINDOWS AND EXTINGUISH ANY OPEN FLAME. DO NOT TOUCH ANY ELECTRICAL SWITCH. DO NOT USE THE TELEPHONE IN YOUR BUILDING - CALL THE GAS COMPANY FROM A NEIGHBOR’S HOUSE AND FOLLOW THE GAS COMPANY’S INSTRUCTIONS. IF YOU CANNOT REACH THE GAS COMPANY, CALL THE FIRE DEPARTMENT. UWARNINGU: DO NOT STORE OR USE GASOLINE OR ANY OTHER FLAMMABLE MATERIAL IN THE VICINITY OF THIS OR ANY OTHER HEATING APPLIANCE. Text Box: Rev. 5/06 Text Box: England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when using smoke or Carbon Monoxide detectors. A letter from our Technical Support department: Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself” store. We intentionally design and build our stoves so that any homeowner can maintain his or her unit with basic tools, and we're always more than happy to show you how to do the job as easily and as inexpensively as possible. From our free, downloadable service sheets; to our Pellet Service Video; to our new "wizard-style," click-through Troubleshooting guide on our web site, we have always tried to help our customers stay "heat-ready," especially when oil and electricity prices continue to skyrocket. Please look at our vast Help section on our web site and call our Customer Service department at (800) 245-6489 if you need any help with your unit. We are nearly always able to help “walk you through” any repairs, problems or questions you may have. PLEASE NOTE: While information obtained on our web site and through our 800 number is always free of charge, there will be a service charge incurred with any “on-site” repairs or maintenance that we may arrange. Wishing you years of efficient, quality and “comfy” heating, England’s Stove Works Technical Support Department (800) 245-6489 Text Box: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER. CONTACT CUSTOMER SERVICE at 1 (800) 245-6489. SAFETY PRECAUTIONS THIS VENTED GAS FIREPLACE HEATER MUST BE INSTALLED, REPAIRED AND INSPECTED ANNUALLY BY QUALIFIED SERVICE PERSONNEL. IT IS ALSO RECOMMENDED THAT IT BE INSPECTED BEFORE USE. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING AND BEDDING TYPE MATERIAL. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS BE KEPT CLEAN; FAILURE TO PROPERLY INSTALL, ADJUST AND MAINTAIN THIS APPLIANCE MAY RESULT IN AN UNSAFE OR HAZARDOUS CONDITION WHICH MAY LEAD TO CARBON MONOXIDE POISONING, FIRE, EXPLOSION, PERSONAL INJURY AND LOSS OF LIFE. DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE PERSON TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OF THE CONTROL SYSTEM THAT HAS BEEN UNDER WATER. ALWAYS CHECK YOUR BUILDING CODES PRIOR TO INSTALLATION. THIS INSTALLATION MUST COMPLY WITH ALL LOCAL, REGIONAL, STATE AND NATIONAL CODES AND REGULATIONS. THIS UNIT IS DESIGNED TO BURN EITHER NATURAL GAS (NG MODEL) OR LIQUID PROPANE (LP MODEL) GAS AND IS MADE TO ORDER; THERE IS NO CONVERSION KIT AVAILABLE. NEVER BURN PAPER, WOOD OR ANY OTHER MATERIAL IN THIS UNIT. NEVER LEAVE CHILDREN UNATTENDED WHEN THERE IS A FIRE IN THE HEATER. NEVER USE GASOLINE, KEROSENE, CHARCOAL LIGHTER FLUID OR ANY OTHER LIQUID FUEL IN THIS UNIT. DO NOT STORE GASOLINE OR OTHER FLAMMABLE MATERIALS IN THE VICINITY OF THIS HEATER. THIS VENTED GAS FIREPLACE HEATER MUST BE ELECTRICALLY CONNECTED AND GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE CURRENT EDITION NFPA 70-NATIONAL ELECTRIC CODE OR CSA C22.1-CANADIAN ELECTRICAL CODE. WHILE SERVICING THIS UNIT, ALL ELECTRICITY AND GAS SHOULD BE COMPLETELY SHUT OFF. ALWAYS BE SURE THE STOVE IS COMPLETELY COOLED DOWN PRIOR TO DOING ANY TYPE OF SERVICE WORK. THIS STOVE HAS A STANDING PILOT LIGHT THAT IS LIT USING A PIEZO ELECTRIC SPARK GENERATOR AS DESCRIBED IN OTHER PARTS OF THIS MANUAL. NEVER ATTEMP...

Эта инструкция также подходит к моделям:
Плиты - 60-SHBVLP (289.42 kb)
Плиты - 60-SHBVNG (289.42 kb)
Плиты - 60-TRBVLP (289.42 kb)
Плиты - 60-TRBVNG (289.42 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории