Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Avalon s, модель Rainier

Производитель: Avalon s
Размер: 633.82 kb
Название файла: 59234b95-74de-45dc-ac0d-d81c04181c1e.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Operate only with door closed.OPTIONAL EQUIPMENT: Front or rear blower (electrical rating: 115V, 60 Hz., 1.8 Amps)Replace glass only with AVALON supplied NEOCERAM ceramic glass (5mm).Do not route power cord under or in front of appliance. • DURAVENT model DVL with DURA-PLUS chimney• AMERI-TEC model DCC with model HS chimney• SECURITY model DP with SECURITY model ASHT or S2100 chimney • GSW model Super Chimney Twenty-One connected directly to appliance• SELKIRK METALBESTOS model DS connector with model SSII chimney• DURAVENT Model DVL with DURA-TECH chimneyFREESTANDING INSTALLATIONSTANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black or 25 MSG blued steel connector,with listed UL-103 HT factory-built chimney, suitable for use with solid fuels or masonry chimney. Pedestal or legs are required.ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Pedestal or legs are required. Maximum alcove depth 48” , minimum alcove height 84” .MOBILE HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. In addition,mobile home installations require outside air - use the Avalon Rainier optional pedestal or outside air boot.Pedestal or legs are required. COMBUSTIBLE FACING MANTELHEARTH EXTENSIONINSERT COMBUSTIBLE SIDEWALL NON-COMBUSTIBLEFIREPLACE FACING A B C D F ELISTED FIREPLACE INSERT FOR INSTALLATION INTO A FACTORY- BUILT (Z.C.) FIREPLACE OR MASONRY FIREPLACEMinimum Clearance to Masonry Factory-BuiltCombustibles and Hearth Fireplace (Z.C.) FireplaceRequirements Installations Installations A. 14.0” 30.0” B. 13.0” 12.0” C. 29.5” 12.0” With Shield 14.5” N/A D. 31.5” 24.0” With Shield 16.5” N/A Hearth Extension Front 16” 16” Hearth Extension to Sides 8” 8” Freestanding Clearance Diagram Floor Protection DiagramAlcove SpecificationsMax. Alcove Depth 48 in. Min. Alcove Height 84 in.Min. Alcove Width990: 53.5 in.945: 57.5 in. Floor protection must be a non-com-bustible material extending beneath theheater and to the front, sides and backas indicated. See Owner's Manual forexamples of non-combustible materialsthat can be used. FRONTSTOVE FLOOR PROTECTOR6 6 6 16 45° STOVE STOVEADJACENT WALL ADJACENT WALL BACKWALL SIDEWALL E D F B A C Rainier 90Singlewall connectorConventional residentialInstallation Rainier 45Singlewall connectorConventional residentialInstallation Rainier 45Alcove, Mobile home, and reducedclearance conventional residentialInstallation Rainier 90Alcove, Mobile home, and reducedclearance conventional residentialInstallation A.B.C.D.E.F. Sidewall to UnitBackwall to UnitCorner to UnitSidewall to ConnectorBackwall to ConnectorCorner to Connector 14.0 in.14.5 in.11.0 in.24.0 in.15.75 in.20.0 in. 14.0 in.9.5 in.7.5 in.23.5 in.10.25 in.16.0 in. 14.0 in.17.5 in.11.0 in.24.0 in15.5 in.16.5 in. 16.0 in.14.0 in.7.5 in.25.5 in.10.0 in.12.0 in. Minimum Clearance to Combustible Materials - Freestanding InstallationFactory-Built (Z.C.) Fireplace installations require a minimum 24” starter section directly connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.) Fireplace chimney must have a minimum cross-sectional area of 28.85” . The Factory-Built (Z.C.) Fireplace damper and control must be removed, or secured in theopen position. For minimum Factory-Built (Z.C.) Fireplace firebox size, see manufacturer’s installation instructions. Factory-Built (Z.C.) Fireplace floor protectionmust be 3/8” minimum non-combustible material or equivalent, extending 16” in front of insert and 8” to both sides. A metal deflector plate must be installed if theflue collar is not completely behind the lintel plate of the Factory-Built (Z.C.) Fireplace openings. Travis Industries 100-01140 4020628 Optional Equipment 37 Optional Equipment 37 Stove Leg Installation (Brass # 99200500, Cast Black # 99200800, Sculptured # 99200105) Raise the stove 8" (use lumber). Attach each leg following the instructions below. Attach each leg to the stove by inserting a bolt and washer through the hole or slot in the leg and into the threaded hole on the stove. These rubber-tipped bolts are for leveling the stove. Make sure they contact the floor. Do not adjust with weight on the legs, the rubber tips may tear. Pedestal (Part # 99200127) 9/16" Socket Wrench If using outside air with the pedestal, follow the directions on the following page under "Outside Air Installation" prior to installing the pedestal. 1 Place the pedestal into position on the floor protection. Lift the pedestal up and insert the two dowels included with this kit onto the forward and rear edge of the pedestal base. 2 Lift the stove onto the pedestal base. Line up the press-nuts on the bottom of the stove with the two attachment brackets on the pedestal. Insert the two bolts, with washers, through the brackets on the pedestal and into the stove. Tighten the bolts with a 9/16" wrench. ! Mobile Home installations require the pedestal to be attached to the floor (use the ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории