Manual Bypass Switch for constant steaming. ¦ Durable 14 Gauge, 304 Stainless Steel construction for compartment door, cooking cavity and steam generator ¦ Exclusive Gemini Drain/Power Control System: Manual 1/2 inch "Ball Valve" type drain that controls main powerOn/Off and automatically fills generator (located on the control panel) ¦ Exclusive Brass Steam Jets distribute steam even throughout cooking compartment ¦ Easy, Front -Access Generator Controls comes with a pullout drawer for simple servicing of unit ¦ 6 Stainless Steel Adjustable Legs with Flanged Feet ¦ Approvals: CSA (AGA, CSA) and U.L/NSF#4 . Propane Gas (PG) ¦ Compartment Steam Shut-Off Switch when compartment door is opened . Dissolve ® Descale Solution, 6 one gallon container w/quart markings (106174) . Water Filters Options & Accessories . Electronic Timer with Compensating Feature (ETC) . On/Off Steam Switch Controls, no timer (MC) SECT. IV PAGE 11 1007 ClevelandSteamCraft.GeminiTMModel24CGA6.2S,54.5"high, Twocompartmentsteamer.Independentsteamgenerators,50,000BTU'sinputpercompartment."SureCook"electromechanicaltimerwithloadcompensatingfeature.Gasvalveandwaterlevelcontrolsystem.Exclusiveremoteprobe-typewaterlevelcontrols. ExclusiveBrass“SteamJet”distributionsystem.Two-piecefree- floatingcompartmentdoor.14gaugestainlesssteelcavityanddoor.PulloutservicedrawerforcontrolsandGeminiDrain/PowerControlSystem. ShortFormSpecifications 1333 East 179 St., Tel: 1-216-481-4900 Web Site: Cleveland, Ohio, U.S.A. 44110 Fax: 1-216-481-3782 Email: Steam@ClevelandRange.com GAS ELECTRIC COLD WATER CLEARANCE DRAINAGE 11.4. IPS line size, 3.4. connection 120V-1Phase, 60 Hz. 35 psi minimum RIGHT = 12.00. NATURAL PROPANE BTU 2 Blowers & Controls 60 psi maximum LEFT = 3.00. Piping 3.4. N.P.T. Piping 3.4. N.P.T. 50,000 each 150 watts each C2 3.8. dia. NPT for Generator REAR = 3.00. Supply pressure Supply pressure Generator, C1 3.8. dia. NPT for Condenser Allow 6. space min. 4.50. W.C. Min. 11.00. W.C. Min. 100,000 total ** Do not connect to GFI from rear and sides 14.00. W.C. Max. 14.00. W.C. Max. outlet. See note below. When located near combustible walls Manufacturer must be notified if unit will be used above 2,000 feet 20.63" (524mm) 33.13" (842mm) 4.87" (124mm) 3.00" TYP 7.75" (76mm) (197mm) 10.44" (265mm) 5.00" (127mm) 4.00" (102mm) 12.00" (305mm) 24.00" (508mm) 12.76" (324mm) 15.06" (383mm) 17.43" (443mm) 37.13" (943mm) 13.25" (337mm) 10.00" (254mm) 20.88" (530mm) 4.75" (121mm) 13.88" (353mm) 20.36" (517mm) 17.25" TYP (438mm) 21.50" (546mm) 59.21" (1504mm) 30.25" (768) 5.00" (127mm) 7.34" (186mm) 20.50" (521mm) 2.06" (52mm) 6.60" (168mm) 33.13" (842) 6.13" (156mm) 24.00" (610mm) OPERATING CLEARANCE SECONDARY CLEARANCE C2 D C1 (NOT TO SCALE) SECT. IV PAGE 12 1007 Litho in U.S.A. Each Compartment has Capacity for: • Three 21.2. x 12. x 20. Steam Table Pans • Six 1. x 12. x 20. Steam Table Pans • Two 4. x 12. x 20. Steam Table Pans C NOTES: **DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA). D WATER QUALITY REQUIREMENTS The quality of water varies greatly from region to region. Steam equipment generators must be drained daily and chemically descaled periodically to ensure proper operation. To minimize service problems caused by the accumulation of minerals and chemicals in water review the following quality guidelines with a local water treatment specialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than 7.5, Chlorine less than 30 ppm. Right - 3”, Left - 3”, Rear - 3” (12” on control side if adjoining wall or equipment is over 30” high for service access) Contact factory for variances to clearances. 11.2. dia. Do not connect other units to this drain Drain must not be located beneath the steamer itself Preferred floor drain location should be a minimum distance (from the unit) of at least 12” from the left side, 12" from the right side, 6” from the front and 6" from the rear Do not use PVC pipe ...