Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации Fedders, модель Portable Dehumidifier

Производитель: Fedders
Размер: 552.26 kb
Название файла: 6bc94610-e6f5-4ee1-a7e3-64f5a962f86b.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


The unit will power up and display the room temperature. 2. Press the Mode button until the orange indicator light shines above the word Dehumidify. 3. Condensed water may accumulate in the unit. If the internal tank becomes full, the warning light will shine and the unit will not operate until the unit has been drained. See Draining Excess Water section. 4. The fan will operate in Med speed. Fan speed is not adjustable in Dehumidify mode. Fan Mode 1. Press the On/Off button to turn the unit on. The unit will power up and display the room temperature. 2. Press the Mode button until the yellow indicator light shines. 3. Press the Fan Speed button to select the desired setting (High, Med, Low). The fan speed indicator light will shine for the selected speed. 4. The unit will operate continuously in Fan mode. Timer The timer can be set to turn the unit off or on. The timer is adjustable between 1 and 12 hours. To turn unit off automatically: 1. With unit running in desired mode, press timer button. 2. Use Temp/Timer Set buttons to select number of hours you would like the unit to run until it automatically shuts off. After you have finished adjusting the timer, the display will default back to the room temperature and the “Room Temp” indicator will shine. Timer indicator will blink when set. To turn timer off press the timer button. To turn unit on automatically: 1. With unit powered on select desired mode and fan speed, then power unit off. 2. With machine powered off, press timer button to select number of hours until you would like the unit to automatically start running in air conditioning mode. Timer indicator will blink when set. The display will show the number of hours the unit is set until it begins operation. To turn timer off press the timer button. 7 Maintenance Cleaning and Maintenance • The unit has an air filter that must be cleaned with water every two weeks and put back in the unit after it is completely dry. • The air discharge grille can be cleaned with a rag or sponge, warm water and mild detergent. • Never use hot water, bleach, gasoline, acids, cleaning fluid or a brush to clean the unit. This will damage the cabinet and the air discharge area. • Do not wash the unit with a hose. Cleaning the filter. 1. Turn Power OFF. 2. Remove the air filter by grasping the bottom and pulling it up and out of the unit. 3. Wash in hot soapy water, rinse and shake dry. 4. Replace the filter with the front of the filter toward you. 5. To dry the filter thoroughly, run your unit in fan mode for a few minutes. Remember, only a clean filter works properly and delivers top efficiency at every setting. Warning: Make sure unit is unplugged before performing any maintenance procedure. Draining excess water Condensed water may accumulate in the unit. If the internal tank becomes full, the Warning Light will shine and the unit will not operate until the unit has been drained. First, uplug electrical cord from wall outlet. Then, drain excess water from the tank by placing a pan under the drain valve, removing the drain plug, and letting the water drain into the pan. When the water stops draining out, replace the drain plug, and remove the pan of water. Operate the air conditioner in fan mode to dry the interior of the unit. Always drain the unit before putting it into storage. Air Conditioner Remote Control The functions work the same as your air conditioner’s touch controls. Batteries: Remove the cover on the back of the remote controller and insert the batteries with the (+) and (-) poles pointing in the proper direction. 10 Removing the filter Proper use and care of your air conditioner will help ensure longer life of the unit. It is recommended to have a professional annually inspect and clean the coils and condensate water passages. Expense of annual inspection is the consumer’s responsibility. CAUTION Failure to keep air filter clean will result in poor air circulation. DO NOT operate without filter. This can render the unit inoperative. Drain Valve 11 AAA IEC R031.5V + - AAA IEC R031.5V CAUTION: • Use only AAA or IEC R03 1.5V batteries. • Do not attempt to recharge the supplied batteries • All batteries should be replaced at the same time. • Do not dispose of the batteries in a fire as they may explode. • Do not mix old and new batteries. • Do not install the batteries with the polarity (+/–) reversed. • Do not mix alkaline, standard (carbon - zinc), or rechargeable (nickel-cadmium) batteries. • Keep batteries and other things that could be swallowed away from young children. Contact a doctor immediately if an object is swallowed. 8 Service & warranty How to obtain Warranty Service or Parts Service for your unit will be provided by CareCo, with authorized independent CareCo servicers nationwide. Note: Before calling for service, carefully read the Installation and Operating instructions booklet. Then if you need service: 1. Call a CareCo authorized servicer and advise them of model number, serial number, date...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории