|
Фрагмент инструкции
How to Select the Desired Humidity Level 1) Push the stand-by button. 2) Press the button to set the desired humidty level. (30% means a dry environment, 80% a humid environment). 3) Push the MODE button to choose the dehumidifying function; the function is selected when the small dot on the display is under the symbol). 4) When the appliance reaches the humidity set point the appliance will automatically stop working. As soon as the humidity increases above the set point, the appliance will automatically resume dehumidification operation. Note: The appliance is equipped with a safety device. The appliance only works after 3 minutes from the last time it was turned off. How to use the FAN function 1) Push the stand-by button. 2) Push the MODE button to choose the FAN function; the function is selected when the small dot on the display is under the symbol). 3) Press the button to modify the ventilation speed (min/med/max). Turbo power 1) Press the button. 2) The turbo power function is an automatic dehumidification function that is used when you wish to operate the appliance at maximum power. When in this mode, the display will show on the left side (two dots) and on the right side the room humidity present. To stop the turbo power function, simply press the button again. How to program the delayed start function: From the OFF Position 1) With the unit OFF, press the button and use the button to set the number of hours after which the appliance should start functioning. 2) On the left side the display will show the number of hours after which the appliance should start the operation (1-24h) and a small dot under the symbol indicates that the timer function has been selected. 3) When the selected time is reached, the appliance will start working. ENGLISH 9 Selecting the operations How to Program the delayed stop function: From the ON Position 1) Press the button and use the button to set the number of hours after which the appliance should stop functioning. 2) The left side the display will show the number of hours after which the appliance should stop the operation (1-24h) and a small dot under the tion has been selected. symbol indicates that the timer func3) When the selected time is reached, the appliance will stop working. Care and Maintenance ENGLISH WARNING Electrical Shock Hazard Always disconnect power supply cord from outlet before performing any maintenance. Failure to follow the below precautions could result in the electrical shock or personal injuries. Maintenance Your dehumidifier is designed to serve you year-round. Listed below are the care and maintenance instructions Cleaning the Front Panel and Cabinet • Using a soft cloth, clean the front panel and cabinet with warm water and a mild soap or detergent. NOTE: Never sprinkle water into the appliance in order to prevent risk of short- circuit and fire. • Never use gasoline, thinner or any other similar chemicals for cleaning. • Do not use bleach or abrasives. Cleaning the Air Filter If the filter is dirty, air circulation is compromised and the efficiency of the dehumidifying decreases. It is therefore good practice to clean the filter at regular intervals. The frequency depends on the duration and conditions of operation. •To remove the air filter, pull it out (Fig. 6). • Use a vacuum cleaner to remove dust accumulations from the filter. If the filter is very dirty, wash in warm water and rinse several times. • After washing the filter, allow it to dry completely before replacing it. fig. 6 11 Troubleshooting tips Often times, a problem is minor and a service call may not be necessary. Use this troubleshooting guide to identify possible problems you may be experiencing. Problem Possible cause Remedy Unit does not operate •Check power cord connection. •Check if water tank is full •Check water tank is properly installed. •Check if the unit is not turned on. •The desired humidity may be lower than the room humidity. •Plug into the power outlet •Empty the tank •Position the tank correctly •Turn the unit on Dehumidifying capacity (moi• Air filter is dirty and /or •Clean the filter sture removal) low blocked. •Ambient room temperature too low. •Poor airflow circulation/obstruction •The desired humidity is lower then the room humidity •Increase the room temperature •Improve the airflow Relative Humidity setting not reached after long period of operation •There are windows or doors opened •Area/room is too large for the capacity of the dehumidifier •Check that the doors and the windows are closed. The appliance does not work in the 3 minutes since the last swith off •The safety device has been activated •Wait 3 minutes to pass The display shows “E1”/“E2”/“E3” •Contact the Service Center The pump lamp blink •The condensation discharge hose is not positioned corretly or is bent. •Check the hose is correctly positioned •Disconnect and reconnect the appliance Limited Warranty This warranty applies to all home appliances with De’Longhi or Kenwood brand n...
Эта инструкция также подходит к моделям:Осушители воздуха - DE300P (154.93 kb)
Осушители воздуха - DE650P (154.93 kb)