Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Campbell Hausfeld, модель FP2000

Производитель: Campbell Hausfeld
Размер: 3.85 mb
Название файла: 29285bf1-b7d5-49d4-b195-c808ea38af37.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


! CAUTION Overheating, short circuiting and fire damage will result from inadequate wiring, etc. GROUNDING INSTRUCTIONS 1. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. Improper use of grounding plug can result in a possible risk of electrical shock! ! DANGER Figure 3 - Grounding Method Grounding Pin Grounded Outlet NOTE: Do not use grounding adapter. MOISTURE IN COMPRESSED AIR Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with the spray material. IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line, located as near to the gun as possible, will help eliminate this moisture. Extension cords for 120V/15 Amp Unit Length of Cord (ft) 25 50 100 150 200 250 300 400 500 Gauge of Cord 14 10 10 8 6 6 4 4 2 3 Operating Instructions Oil Lubricated Portable Preparation (Cont.) 2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The grounding wire has insulation and an outer surface that is green with or without yellow stripes. 3. Check with a qualified electrician or serviceman to ensure product is properly grounded. Do not modify plug provided; if plug will not fit outlet, have proper outlet installed by a qualified electrician. Never connect ! WARNING green (or green and yellow) wire to a live terminal. EXTENSION CORDS Avoid using an extension cord. To extend the reach of the compressor, additional air hose is recommended. 1. Use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept plug on product. 2. Make sure extension cord is in good condition, and heavy enough to carry current product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. 3. The chart on page 3 shows correct size to use depending on cord length and nameplate ampere rating. If in doubt, use next heavier gauge. NOTE: The smaller the gauge number, the heavier the cord. Operation FOR TROUBLE-FREE OPERATION 1. Keep compressor level during operation and while checking oil level. 2. Check oil level before each use. Add oil to full line on the dipstick. Operation with low oil will damage pump and may cause difficulty in starting. 3. Read instructions: Carefully read through this owner’s manual BEFORE OPERATING the new air compressor. It contains information about operation and maintenance of unit. 4. Drain tank daily: Open drain cocks and tilt unit to drain moisture from tanks (See Figure 12). Be sure to close drain cocks tightly before operating compressor. This helps prevent tank corrosion and keeps oil and moisture out of compressed air. MANUAL 5. Check air filter: Never run compressor without an air filter nor with a clogged air filter. See maintenance section for cleaning and replacement instructions. BREAK-IN Break-in: Allow new compressor to run for at least 30 minutes without compressing air, to properly seat working parts. Do not attach air ! CAUTION chuck or other tool to open end of hose until start-up has been completed and unit checks OK. Close Open Attach Hose Air Flow Figure 4 1. Turn regulator knob fully clockwise. 2. Turn switch or knob to OFF position, and plug in power cord. 3. Turn switch or knob to AUTO position and run unit for 30 minutes to break in pump parts. OFF position AUTO / OFF AUTO position Figure 5 4. Turn regulator knob fully counterclockwise. Compressor will build to maximum preset pressure and shut off. 5. Turn regulator knob clockwise to cause air to bleed off. Compressor will restart at present pressure. 6. Turn regulator knob counterclockwise to shut off air and turn switch to OFF position. 7. Attach air chuck or other tool to open end of hose. Turn regulator fully ON. Apply a soap and water solution around hose fittings and check for signs of leaks (bubbles forming). If there is a leak, tighten connections and check again. When there are no leaks, compressor is ready for operation. Figure 6 ASME SAFETY VALVE 1. This valve automatically releases air if air receiver pressure exceeds preset maximum. Do not attempt to! DANGER tamper with this valve! 2. This valve should be checked occasionally by...

Эта инструкция также подходит к моделям:
Насосное оборудование - FP2012 (3.85 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории